summaryrefslogtreecommitdiffstats
path: root/drivers/i2c/Kconfig
blob: 9a62ddd9ca28dffe69dd78cfd10d4d4941a9ceb9 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
config DM_I2C
	bool "Enable Driver Model for I2C drivers"
	depends on DM
	help
	  Enable driver model for I2C. The I2C uclass interface: probe, read,
	  write and speed, is implemented with the bus drivers operations,
	  which provide methods for bus setting and data transfer. Each chip
	  device (bus child) info is kept as parent platdata. The interface
	  is defined in include/i2c.h. When i2c bus driver supports the i2c
	  uclass, but the device drivers not, then DM_I2C_COMPAT config can
	  be used as compatibility layer.

config DM_I2C_COMPAT
	bool "Enable I2C compatibility layer"
	depends on DM
	help
	  Enable old-style I2C functions for compatibility with existing code.
	  This option can be enabled as a temporary measure to avoid needing
	  to convert all code for a board in a single commit. It should not
	  be enabled for any board in an official release.

config I2C_CROS_EC_TUNNEL
	tristate "Chrome OS EC tunnel I2C bus"
	depends on CROS_EC
	help
	  This provides an I2C bus that will tunnel i2c commands through to
	  the other side of the Chrome OS EC to the I2C bus connected there.
	  This will work whatever the interface used to talk to the EC (SPI,
	  I2C or LPC). Some Chromebooks use this when the hardware design
	  does not allow direct access to the main PMIC from the AP.

config I2C_CROS_EC_LDO
	bool "Provide access to LDOs on the Chrome OS EC"
	depends on CROS_EC
	---help---
	On many Chromebooks the main PMIC is inaccessible to the AP. This is
	often dealt with by using an I2C pass-through interface provided by
	the EC. On some unfortunate models (e.g. Spring) the pass-through
	is not available, and an LDO message is available instead. This
	option enables a driver which provides very basic access to those
	regulators, via the EC. We implement this as an I2C bus	which
	emulates just the TPS65090 messages we know about. This is done to
	avoid duplicating the logic in the TPS65090 regulator driver for
	enabling/disabling an LDO.

config DM_I2C_GPIO
	bool "Enable Driver Model for software emulated I2C bus driver"
	depends on DM_I2C && DM_GPIO
	help
	  Enable the i2c bus driver emulation by using the GPIOs. The bus GPIO
	  configuration is given by the device tree. Kernel-style device tree
	  bindings are supported.
	  Binding info: doc/device-tree-bindings/i2c/i2c-gpio.txt

config SYS_I2C_SANDBOX
	bool "Sandbox I2C driver"
	depends on SANDBOX && DM_I2C
	help
	  Enable I2C support for sandbox. This is an emulation of a real I2C
	  bus. Devices can be attached to the bus using the device tree
	  which specifies the driver to use. As an example, see this device
	  tree fragment from sandbox.dts. It shows that the I2C bus has a
	  single EEPROM at address 0x2c (7-bit address) which is emulated by
	  the driver for "sandbox,i2c-eeprom", which is in
	  drivers/misc/i2c_eeprom_emul.c.

	  i2c@0 {
		#address-cells = <1>;
		#size-cells = <0>;
		reg = <0>;
		compatible = "sandbox,i2c";
		clock-frequency = <400000>;
		eeprom@2c {
			reg = <0x2c>;
			compatible = "i2c-eeprom";
			emul {
				compatible = "sandbox,i2c-eeprom";
				sandbox,filename = "i2c.bin";
				sandbox,size = <128>;
			};
		};
	};


config SYS_I2C_UNIPHIER
	bool "UniPhier I2C driver"
	depends on ARCH_UNIPHIER && DM_I2C
	default y
	help
	  Support for UniPhier I2C controller driver.  This I2C controller
	  is used on PH1-LD4, PH1-sLD8 or older UniPhier SoCs.

config SYS_I2C_UNIPHIER_F
	bool "UniPhier FIFO-builtin I2C driver"
	depends on ARCH_UNIPHIER && DM_I2C
	default y
	help
	  Support for UniPhier FIFO-builtin I2C controller driver.
	  This I2C controller is used on PH1-Pro4 or newer UniPhier SoCs.

source "drivers/i2c/muxes/Kconfig"
OpenPOWER on IntegriCloud