summaryrefslogtreecommitdiffstats
path: root/cpu/bf537/cache.S
blob: 5bda5bf97f715e2946d67b6e6dc54cb9b51ebc65 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
#define ASSEMBLY
#include <asm/linkage.h>
#include <config.h>
#include <asm/blackfin.h>

.text
.align 2
ENTRY(_blackfin_icache_flush_range)
	R2 = -32;
	R2 = R0 & R2;
	P0 = R2;
	P1 = R1;
	CSYNC;
	1:
	IFLUSH[P0++];
	CC = P0 < P1(iu);
	IF CC JUMP 1b(bp);
	IFLUSH[P0];
	SSYNC;
	RTS;

ENTRY(_blackfin_dcache_flush_range)
	R2 = -32;
	R2 = R0 & R2;
	P0 = R2;
	P1 = R1;
	CSYNC;
1:
	FLUSH[P0++];
	CC = P0 < P1(iu);
	IF CC JUMP 1b(bp);
	FLUSH[P0];
	SSYNC;
	RTS;

ENTRY(_icache_invalidate)
ENTRY(_invalidate_entire_icache)
	[--SP] = (R7:5);

	P0.L = (IMEM_CONTROL & 0xFFFF);
	P0.H = (IMEM_CONTROL >> 16);
	R7 =[P0];

	/*
	 * Clear the IMC bit , All valid bits in the instruction
	 * cache are set to the invalid state
	 */
	BITCLR(R7, IMC_P);
	CLI R6;
	/* SSYNC required before invalidating cache. */
	SSYNC;
	.align 8;
	[P0] = R7;
	SSYNC;
	STI R6;

	/* Configures the instruction cache agian */
	R6 = (IMC | ENICPLB);
	R7 = R7 | R6;

	CLI R6;
	SSYNC;
	.align 8;
	[P0] = R7;
	SSYNC;
	STI R6;

	(R7:5) =[SP++];
	RTS;

/*
 * Invalidate the Entire Data cache by
 * clearing DMC[1:0] bits
 */
ENTRY(_invalidate_entire_dcache)
ENTRY(_dcache_invalidate)
	[--SP] = (R7:6);

	P0.L = (DMEM_CONTROL & 0xFFFF);
	P0.H = (DMEM_CONTROL >> 16);
	R7 =[P0];

	/*
	 * Clear the DMC[1:0] bits, All valid bits in the data
	 * cache are set to the invalid state
	 */
	BITCLR(R7, DMC0_P);
	BITCLR(R7, DMC1_P);
	CLI R6;
	SSYNC;
	.align 8;
	[P0] = R7;
	SSYNC;
	STI R6;
	/* Configures the data cache again */

	R6 = (ACACHE_BCACHE | ENDCPLB | PORT_PREF0);
	R7 = R7 | R6;

	CLI R6;
	SSYNC;
	.align 8;
	[P0] = R7;
	SSYNC;
	STI R6;

	(R7:6) =[SP++];
	RTS;

ENTRY(_blackfin_dcache_invalidate_range)
	R2 = -32;
	R2 = R0 & R2;
	P0 = R2;
	P1 = R1;
	CSYNC;
1:
	FLUSHINV[P0++];
	CC = P0 < P1(iu);
	IF CC JUMP 1b(bp);

	/*
	 * If the data crosses a cache line, then we'll be pointing to
	 * the last cache line, but won't have flushed/invalidated it yet, so do
	 * one more.
	 */
	FLUSHINV[P0];
	SSYNC;
	RTS;
OpenPOWER on IntegriCloud