summaryrefslogtreecommitdiffstats
path: root/drivers/mmc
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/mmc')
-rw-r--r--drivers/mmc/host/sdhci.c24
1 files changed, 9 insertions, 15 deletions
diff --git a/drivers/mmc/host/sdhci.c b/drivers/mmc/host/sdhci.c
index 447eef8217c7..47055f3f01b8 100644
--- a/drivers/mmc/host/sdhci.c
+++ b/drivers/mmc/host/sdhci.c
@@ -1823,7 +1823,6 @@ static int sdhci_execute_tuning(struct mmc_host *mmc, u32 opcode)
struct sdhci_host *host = mmc_priv(mmc);
u16 ctrl;
int tuning_loop_counter = MAX_TUNING_LOOP;
- unsigned long timeout;
int err = 0;
unsigned long flags;
@@ -1882,14 +1881,10 @@ static int sdhci_execute_tuning(struct mmc_host *mmc, u32 opcode)
* Issue CMD19 repeatedly till Execute Tuning is set to 0 or the number
* of loops reaches 40 times or a timeout of 150ms occurs.
*/
- timeout = 150;
do {
struct mmc_command cmd = {0};
struct mmc_request mrq = {NULL};
- if (!tuning_loop_counter && !timeout)
- break;
-
cmd.opcode = opcode;
cmd.arg = 0;
cmd.flags = MMC_RSP_R1 | MMC_CMD_ADTC;
@@ -1897,6 +1892,9 @@ static int sdhci_execute_tuning(struct mmc_host *mmc, u32 opcode)
cmd.data = NULL;
cmd.error = 0;
+ if (tuning_loop_counter-- == 0)
+ break;
+
mrq.cmd = &cmd;
host->mrq = &mrq;
@@ -1954,8 +1952,6 @@ static int sdhci_execute_tuning(struct mmc_host *mmc, u32 opcode)
host->tuning_done = 0;
ctrl = sdhci_readw(host, SDHCI_HOST_CONTROL2);
- tuning_loop_counter--;
- timeout--;
/* eMMC spec does not require a delay between tuning cycles */
if (opcode == MMC_SEND_TUNING_BLOCK)
@@ -1966,17 +1962,15 @@ static int sdhci_execute_tuning(struct mmc_host *mmc, u32 opcode)
* The Host Driver has exhausted the maximum number of loops allowed,
* so use fixed sampling frequency.
*/
- if (!tuning_loop_counter || !timeout) {
+ if (tuning_loop_counter < 0) {
ctrl &= ~SDHCI_CTRL_TUNED_CLK;
sdhci_writew(host, ctrl, SDHCI_HOST_CONTROL2);
+ }
+ if (!(ctrl & SDHCI_CTRL_TUNED_CLK)) {
+ pr_info(DRIVER_NAME ": Tuning procedure"
+ " failed, falling back to fixed sampling"
+ " clock\n");
err = -EIO;
- } else {
- if (!(ctrl & SDHCI_CTRL_TUNED_CLK)) {
- pr_info(DRIVER_NAME ": Tuning procedure"
- " failed, falling back to fixed sampling"
- " clock\n");
- err = -EIO;
- }
}
out: