summaryrefslogtreecommitdiffstats
path: root/drivers/media/cec/cec-adap.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/media/cec/cec-adap.c')
-rw-r--r--drivers/media/cec/cec-adap.c20
1 files changed, 14 insertions, 6 deletions
diff --git a/drivers/media/cec/cec-adap.c b/drivers/media/cec/cec-adap.c
index bd76c15ade4f..bf45977b2823 100644
--- a/drivers/media/cec/cec-adap.c
+++ b/drivers/media/cec/cec-adap.c
@@ -368,6 +368,8 @@ int cec_thread_func(void *_adap)
* transmit should be canceled.
*/
err = wait_event_interruptible_timeout(adap->kthread_waitq,
+ (adap->needs_hpd &&
+ (!adap->is_configured && !adap->is_configuring)) ||
kthread_should_stop() ||
(!adap->transmitting &&
!list_empty(&adap->transmit_queue)),
@@ -383,7 +385,9 @@ int cec_thread_func(void *_adap)
mutex_lock(&adap->lock);
- if (kthread_should_stop()) {
+ if ((adap->needs_hpd &&
+ (!adap->is_configured && !adap->is_configuring)) ||
+ kthread_should_stop()) {
cec_flush(adap);
goto unlock;
}
@@ -682,7 +686,7 @@ int cec_transmit_msg_fh(struct cec_adapter *adap, struct cec_msg *msg,
return -EINVAL;
}
if (!adap->is_configured && !adap->is_configuring) {
- if (msg->msg[0] != 0xf0) {
+ if (adap->needs_hpd || msg->msg[0] != 0xf0) {
dprintk(1, "%s: adapter is unconfigured\n", __func__);
return -ENONET;
}
@@ -1158,7 +1162,9 @@ static int cec_config_log_addr(struct cec_adapter *adap,
*/
static void cec_adap_unconfigure(struct cec_adapter *adap)
{
- WARN_ON(adap->ops->adap_log_addr(adap, CEC_LOG_ADDR_INVALID));
+ if (!adap->needs_hpd ||
+ adap->phys_addr != CEC_PHYS_ADDR_INVALID)
+ WARN_ON(adap->ops->adap_log_addr(adap, CEC_LOG_ADDR_INVALID));
adap->log_addrs.log_addr_mask = 0;
adap->is_configuring = false;
adap->is_configured = false;
@@ -1387,6 +1393,8 @@ void __cec_s_phys_addr(struct cec_adapter *adap, u16 phys_addr, bool block)
if (phys_addr == adap->phys_addr || adap->devnode.unregistered)
return;
+ dprintk(1, "new physical address %x.%x.%x.%x\n",
+ cec_phys_addr_exp(phys_addr));
if (phys_addr == CEC_PHYS_ADDR_INVALID ||
adap->phys_addr != CEC_PHYS_ADDR_INVALID) {
adap->phys_addr = CEC_PHYS_ADDR_INVALID;
@@ -1396,7 +1404,7 @@ void __cec_s_phys_addr(struct cec_adapter *adap, u16 phys_addr, bool block)
if (adap->monitor_all_cnt)
WARN_ON(call_op(adap, adap_monitor_all_enable, false));
mutex_lock(&adap->devnode.lock);
- if (list_empty(&adap->devnode.fhs))
+ if (adap->needs_hpd || list_empty(&adap->devnode.fhs))
WARN_ON(adap->ops->adap_enable(adap, false));
mutex_unlock(&adap->devnode.lock);
if (phys_addr == CEC_PHYS_ADDR_INVALID)
@@ -1404,7 +1412,7 @@ void __cec_s_phys_addr(struct cec_adapter *adap, u16 phys_addr, bool block)
}
mutex_lock(&adap->devnode.lock);
- if (list_empty(&adap->devnode.fhs) &&
+ if ((adap->needs_hpd || list_empty(&adap->devnode.fhs)) &&
adap->ops->adap_enable(adap, true)) {
mutex_unlock(&adap->devnode.lock);
return;
@@ -1412,7 +1420,7 @@ void __cec_s_phys_addr(struct cec_adapter *adap, u16 phys_addr, bool block)
if (adap->monitor_all_cnt &&
call_op(adap, adap_monitor_all_enable, true)) {
- if (list_empty(&adap->devnode.fhs))
+ if (adap->needs_hpd || list_empty(&adap->devnode.fhs))
WARN_ON(adap->ops->adap_enable(adap, false));
mutex_unlock(&adap->devnode.lock);
return;
OpenPOWER on IntegriCloud