summaryrefslogtreecommitdiffstats
path: root/kernel
diff options
context:
space:
mode:
authorIngo Molnar <mingo@elte.hu>2007-07-09 18:51:57 +0200
committerIngo Molnar <mingo@elte.hu>2007-07-09 18:51:57 +0200
commitd15bcfdbe1818478891d714343f037cfe60875f0 (patch)
tree62362e16a1b189161d0c163085898043e6844a5e /kernel
parent7dcca30a32aadb0520417521b0c44f42d09fe05c (diff)
downloadtalos-obmc-linux-d15bcfdbe1818478891d714343f037cfe60875f0.tar.gz
talos-obmc-linux-d15bcfdbe1818478891d714343f037cfe60875f0.zip
sched: rename idle_type/SCHED_IDLE
enum idle_type (used by the load-balancer) clashes with the SCHED_IDLE name that we want to introduce. 'CPU_IDLE' instead of 'SCHED_IDLE' is more descriptive as well. Signed-off-by: Ingo Molnar <mingo@elte.hu>
Diffstat (limited to 'kernel')
-rw-r--r--kernel/sched.c60
1 files changed, 30 insertions, 30 deletions
diff --git a/kernel/sched.c b/kernel/sched.c
index 50e1a3122699..ac054d9a0719 100644
--- a/kernel/sched.c
+++ b/kernel/sched.c
@@ -496,12 +496,12 @@ static int show_schedstat(struct seq_file *seq, void *v)
/* domain-specific stats */
preempt_disable();
for_each_domain(cpu, sd) {
- enum idle_type itype;
+ enum cpu_idle_type itype;
char mask_str[NR_CPUS];
cpumask_scnprintf(mask_str, NR_CPUS, sd->span);
seq_printf(seq, "domain%d %s", dcnt++, mask_str);
- for (itype = SCHED_IDLE; itype < MAX_IDLE_TYPES;
+ for (itype = CPU_IDLE; itype < CPU_MAX_IDLE_TYPES;
itype++) {
seq_printf(seq, " %lu %lu %lu %lu %lu %lu %lu "
"%lu",
@@ -2208,7 +2208,7 @@ static void pull_task(struct rq *src_rq, struct prio_array *src_array,
*/
static
int can_migrate_task(struct task_struct *p, struct rq *rq, int this_cpu,
- struct sched_domain *sd, enum idle_type idle,
+ struct sched_domain *sd, enum cpu_idle_type idle,
int *all_pinned)
{
/*
@@ -2254,7 +2254,7 @@ int can_migrate_task(struct task_struct *p, struct rq *rq, int this_cpu,
*/
static int move_tasks(struct rq *this_rq, int this_cpu, struct rq *busiest,
unsigned long max_nr_move, unsigned long max_load_move,
- struct sched_domain *sd, enum idle_type idle,
+ struct sched_domain *sd, enum cpu_idle_type idle,
int *all_pinned)
{
int idx, pulled = 0, pinned = 0, this_best_prio, best_prio,
@@ -2372,7 +2372,7 @@ out:
*/
static struct sched_group *
find_busiest_group(struct sched_domain *sd, int this_cpu,
- unsigned long *imbalance, enum idle_type idle, int *sd_idle,
+ unsigned long *imbalance, enum cpu_idle_type idle, int *sd_idle,
cpumask_t *cpus, int *balance)
{
struct sched_group *busiest = NULL, *this = NULL, *group = sd->groups;
@@ -2391,9 +2391,9 @@ find_busiest_group(struct sched_domain *sd, int this_cpu,
max_load = this_load = total_load = total_pwr = 0;
busiest_load_per_task = busiest_nr_running = 0;
this_load_per_task = this_nr_running = 0;
- if (idle == NOT_IDLE)
+ if (idle == CPU_NOT_IDLE)
load_idx = sd->busy_idx;
- else if (idle == NEWLY_IDLE)
+ else if (idle == CPU_NEWLY_IDLE)
load_idx = sd->newidle_idx;
else
load_idx = sd->idle_idx;
@@ -2477,7 +2477,7 @@ find_busiest_group(struct sched_domain *sd, int this_cpu,
* Busy processors will not participate in power savings
* balance.
*/
- if (idle == NOT_IDLE || !(sd->flags & SD_POWERSAVINGS_BALANCE))
+ if (idle == CPU_NOT_IDLE || !(sd->flags & SD_POWERSAVINGS_BALANCE))
goto group_next;
/*
@@ -2639,7 +2639,7 @@ small_imbalance:
out_balanced:
#if defined(CONFIG_SCHED_MC) || defined(CONFIG_SCHED_SMT)
- if (idle == NOT_IDLE || !(sd->flags & SD_POWERSAVINGS_BALANCE))
+ if (idle == CPU_NOT_IDLE || !(sd->flags & SD_POWERSAVINGS_BALANCE))
goto ret;
if (this == group_leader && group_leader != group_min) {
@@ -2656,7 +2656,7 @@ ret:
* find_busiest_queue - find the busiest runqueue among the cpus in group.
*/
static struct rq *
-find_busiest_queue(struct sched_group *group, enum idle_type idle,
+find_busiest_queue(struct sched_group *group, enum cpu_idle_type idle,
unsigned long imbalance, cpumask_t *cpus)
{
struct rq *busiest = NULL, *rq;
@@ -2698,7 +2698,7 @@ static inline unsigned long minus_1_or_zero(unsigned long n)
* tasks if there is an imbalance.
*/
static int load_balance(int this_cpu, struct rq *this_rq,
- struct sched_domain *sd, enum idle_type idle,
+ struct sched_domain *sd, enum cpu_idle_type idle,
int *balance)
{
int nr_moved, all_pinned = 0, active_balance = 0, sd_idle = 0;
@@ -2712,9 +2712,9 @@ static int load_balance(int this_cpu, struct rq *this_rq,
* When power savings policy is enabled for the parent domain, idle
* sibling can pick up load irrespective of busy siblings. In this case,
* let the state of idle sibling percolate up as IDLE, instead of
- * portraying it as NOT_IDLE.
+ * portraying it as CPU_NOT_IDLE.
*/
- if (idle != NOT_IDLE && sd->flags & SD_SHARE_CPUPOWER &&
+ if (idle != CPU_NOT_IDLE && sd->flags & SD_SHARE_CPUPOWER &&
!test_sd_parent(sd, SD_POWERSAVINGS_BALANCE))
sd_idle = 1;
@@ -2848,7 +2848,7 @@ out_one_pinned:
* Check this_cpu to ensure it is balanced within domain. Attempt to move
* tasks if there is an imbalance.
*
- * Called from schedule when this_rq is about to become idle (NEWLY_IDLE).
+ * Called from schedule when this_rq is about to become idle (CPU_NEWLY_IDLE).
* this_rq is locked.
*/
static int
@@ -2865,31 +2865,31 @@ load_balance_newidle(int this_cpu, struct rq *this_rq, struct sched_domain *sd)
* When power savings policy is enabled for the parent domain, idle
* sibling can pick up load irrespective of busy siblings. In this case,
* let the state of idle sibling percolate up as IDLE, instead of
- * portraying it as NOT_IDLE.
+ * portraying it as CPU_NOT_IDLE.
*/
if (sd->flags & SD_SHARE_CPUPOWER &&
!test_sd_parent(sd, SD_POWERSAVINGS_BALANCE))
sd_idle = 1;
- schedstat_inc(sd, lb_cnt[NEWLY_IDLE]);
+ schedstat_inc(sd, lb_cnt[CPU_NEWLY_IDLE]);
redo:
- group = find_busiest_group(sd, this_cpu, &imbalance, NEWLY_IDLE,
+ group = find_busiest_group(sd, this_cpu, &imbalance, CPU_NEWLY_IDLE,
&sd_idle, &cpus, NULL);
if (!group) {
- schedstat_inc(sd, lb_nobusyg[NEWLY_IDLE]);
+ schedstat_inc(sd, lb_nobusyg[CPU_NEWLY_IDLE]);
goto out_balanced;
}
- busiest = find_busiest_queue(group, NEWLY_IDLE, imbalance,
+ busiest = find_busiest_queue(group, CPU_NEWLY_IDLE, imbalance,
&cpus);
if (!busiest) {
- schedstat_inc(sd, lb_nobusyq[NEWLY_IDLE]);
+ schedstat_inc(sd, lb_nobusyq[CPU_NEWLY_IDLE]);
goto out_balanced;
}
BUG_ON(busiest == this_rq);
- schedstat_add(sd, lb_imbalance[NEWLY_IDLE], imbalance);
+ schedstat_add(sd, lb_imbalance[CPU_NEWLY_IDLE], imbalance);
nr_moved = 0;
if (busiest->nr_running > 1) {
@@ -2897,7 +2897,7 @@ redo:
double_lock_balance(this_rq, busiest);
nr_moved = move_tasks(this_rq, this_cpu, busiest,
minus_1_or_zero(busiest->nr_running),
- imbalance, sd, NEWLY_IDLE, NULL);
+ imbalance, sd, CPU_NEWLY_IDLE, NULL);
spin_unlock(&busiest->lock);
if (!nr_moved) {
@@ -2908,7 +2908,7 @@ redo:
}
if (!nr_moved) {
- schedstat_inc(sd, lb_failed[NEWLY_IDLE]);
+ schedstat_inc(sd, lb_failed[CPU_NEWLY_IDLE]);
if (!sd_idle && sd->flags & SD_SHARE_CPUPOWER &&
!test_sd_parent(sd, SD_POWERSAVINGS_BALANCE))
return -1;
@@ -2918,7 +2918,7 @@ redo:
return nr_moved;
out_balanced:
- schedstat_inc(sd, lb_balanced[NEWLY_IDLE]);
+ schedstat_inc(sd, lb_balanced[CPU_NEWLY_IDLE]);
if (!sd_idle && sd->flags & SD_SHARE_CPUPOWER &&
!test_sd_parent(sd, SD_POWERSAVINGS_BALANCE))
return -1;
@@ -3003,7 +3003,7 @@ static void active_load_balance(struct rq *busiest_rq, int busiest_cpu)
schedstat_inc(sd, alb_cnt);
if (move_tasks(target_rq, target_cpu, busiest_rq, 1,
- RTPRIO_TO_LOAD_WEIGHT(100), sd, SCHED_IDLE,
+ RTPRIO_TO_LOAD_WEIGHT(100), sd, CPU_IDLE,
NULL))
schedstat_inc(sd, alb_pushed);
else
@@ -3120,7 +3120,7 @@ static DEFINE_SPINLOCK(balancing);
*
* Balancing parameters are set up in arch_init_sched_domains.
*/
-static inline void rebalance_domains(int cpu, enum idle_type idle)
+static inline void rebalance_domains(int cpu, enum cpu_idle_type idle)
{
int balance = 1;
struct rq *rq = cpu_rq(cpu);
@@ -3134,7 +3134,7 @@ static inline void rebalance_domains(int cpu, enum idle_type idle)
continue;
interval = sd->balance_interval;
- if (idle != SCHED_IDLE)
+ if (idle != CPU_IDLE)
interval *= sd->busy_factor;
/* scale ms to jiffies */
@@ -3154,7 +3154,7 @@ static inline void rebalance_domains(int cpu, enum idle_type idle)
* longer idle, or one of our SMT siblings is
* not idle.
*/
- idle = NOT_IDLE;
+ idle = CPU_NOT_IDLE;
}
sd->last_balance = jiffies;
}
@@ -3184,7 +3184,7 @@ static void run_rebalance_domains(struct softirq_action *h)
{
int local_cpu = smp_processor_id();
struct rq *local_rq = cpu_rq(local_cpu);
- enum idle_type idle = local_rq->idle_at_tick ? SCHED_IDLE : NOT_IDLE;
+ enum cpu_idle_type idle = local_rq->idle_at_tick ? CPU_IDLE : CPU_NOT_IDLE;
rebalance_domains(local_cpu, idle);
@@ -3210,7 +3210,7 @@ static void run_rebalance_domains(struct softirq_action *h)
if (need_resched())
break;
- rebalance_domains(balance_cpu, SCHED_IDLE);
+ rebalance_domains(balance_cpu, CPU_IDLE);
rq = cpu_rq(balance_cpu);
if (time_after(local_rq->next_balance, rq->next_balance))
OpenPOWER on IntegriCloud