summaryrefslogtreecommitdiffstats
path: root/fs/nfs/nfs4filelayout.h
diff options
context:
space:
mode:
authorAndy Adamson <andros@netapp.com>2010-10-20 00:18:04 -0400
committerTrond Myklebust <Trond.Myklebust@netapp.com>2010-10-24 18:07:11 -0400
commit16b374ca439fb406e46e071f75428f5b033056f8 (patch)
tree72a66e452936561151b8b62069763cb4f0434b39 /fs/nfs/nfs4filelayout.h
parentb1f69b754ee312ec75f2c7ead0e6851cd9598cc2 (diff)
downloadtalos-obmc-linux-16b374ca439fb406e46e071f75428f5b033056f8.tar.gz
talos-obmc-linux-16b374ca439fb406e46e071f75428f5b033056f8.zip
NFSv4.1: pnfs: filelayout: add driver's LAYOUTGET and GETDEVICEINFO infrastructure
Implement the driver's io_ops->alloc_lseg and free_lseg functions, which integrate into the deviceid cache and calls out to nfs4_proc_getdeviceinfo when necessary. Signed-off-by: Andy Adamson <andros@netapp.com> Signed-off-by: Dean Hildebrand <dhildebz@umich.edu> Signed-off-by: Marc Eshel <eshel@almaden.ibm.com> Signed-off-by: Mike Sager <sager@netapp.com> Signed-off-by: Oleg Drokin <green@linuxhacker.ru> Signed-off-by: Ricardo Labiaga <ricardo.labiaga@netapp.com> Signed-off-by: Tao Guo <guotao@nrchpc.ac.cn> Signed-off-by: Boaz Harrosh <bharrosh@panasas.com> Signed-off-by: Fred Isaman <iisaman@netapp.com> Signed-off-by: Trond Myklebust <Trond.Myklebust@netapp.com>
Diffstat (limited to 'fs/nfs/nfs4filelayout.h')
-rw-r--r--fs/nfs/nfs4filelayout.h94
1 files changed, 94 insertions, 0 deletions
diff --git a/fs/nfs/nfs4filelayout.h b/fs/nfs/nfs4filelayout.h
new file mode 100644
index 000000000000..bbf60dd2ab9d
--- /dev/null
+++ b/fs/nfs/nfs4filelayout.h
@@ -0,0 +1,94 @@
+/*
+ * NFSv4 file layout driver data structures.
+ *
+ * Copyright (c) 2002
+ * The Regents of the University of Michigan
+ * All Rights Reserved
+ *
+ * Dean Hildebrand <dhildebz@umich.edu>
+ *
+ * Permission is granted to use, copy, create derivative works, and
+ * redistribute this software and such derivative works for any purpose,
+ * so long as the name of the University of Michigan is not used in
+ * any advertising or publicity pertaining to the use or distribution
+ * of this software without specific, written prior authorization. If
+ * the above copyright notice or any other identification of the
+ * University of Michigan is included in any copy of any portion of
+ * this software, then the disclaimer below must also be included.
+ *
+ * This software is provided as is, without representation or warranty
+ * of any kind either express or implied, including without limitation
+ * the implied warranties of merchantability, fitness for a particular
+ * purpose, or noninfringement. The Regents of the University of
+ * Michigan shall not be liable for any damages, including special,
+ * indirect, incidental, or consequential damages, with respect to any
+ * claim arising out of or in connection with the use of the software,
+ * even if it has been or is hereafter advised of the possibility of
+ * such damages.
+ */
+
+#ifndef FS_NFS_NFS4FILELAYOUT_H
+#define FS_NFS_NFS4FILELAYOUT_H
+
+#include "pnfs.h"
+
+/*
+ * Field testing shows we need to support upto 4096 stripe indices.
+ * We store each index as a u8 (u32 on the wire) to keep the memory footprint
+ * reasonable. This in turn means we support a maximum of 256
+ * RFC 5661 multipath_list4 structures.
+ */
+#define NFS4_PNFS_MAX_STRIPE_CNT 4096
+#define NFS4_PNFS_MAX_MULTI_CNT 256 /* 256 fit into a u8 stripe_index */
+
+enum stripetype4 {
+ STRIPE_SPARSE = 1,
+ STRIPE_DENSE = 2
+};
+
+/* Individual ip address */
+struct nfs4_pnfs_ds {
+ struct list_head ds_node; /* nfs4_pnfs_dev_hlist dev_dslist */
+ u32 ds_ip_addr;
+ u32 ds_port;
+ struct nfs_client *ds_clp;
+ atomic_t ds_count;
+};
+
+struct nfs4_file_layout_dsaddr {
+ struct pnfs_deviceid_node deviceid;
+ u32 stripe_count;
+ u8 *stripe_indices;
+ u32 ds_num;
+ struct nfs4_pnfs_ds *ds_list[1];
+};
+
+struct nfs4_filelayout_segment {
+ struct pnfs_layout_segment generic_hdr;
+ u32 stripe_type;
+ u32 commit_through_mds;
+ u32 stripe_unit;
+ u32 first_stripe_index;
+ u64 pattern_offset;
+ struct nfs4_file_layout_dsaddr *dsaddr; /* Point to GETDEVINFO data */
+ unsigned int num_fh;
+ struct nfs_fh **fh_array;
+};
+
+static inline struct nfs4_filelayout_segment *
+FILELAYOUT_LSEG(struct pnfs_layout_segment *lseg)
+{
+ return container_of(lseg,
+ struct nfs4_filelayout_segment,
+ generic_hdr);
+}
+
+extern void nfs4_fl_free_deviceid_callback(struct pnfs_deviceid_node *);
+extern void print_ds(struct nfs4_pnfs_ds *ds);
+extern void print_deviceid(struct nfs4_deviceid *dev_id);
+extern struct nfs4_file_layout_dsaddr *
+nfs4_fl_find_get_deviceid(struct nfs_client *, struct nfs4_deviceid *dev_id);
+struct nfs4_file_layout_dsaddr *
+get_device_info(struct inode *inode, struct nfs4_deviceid *dev_id);
+
+#endif /* FS_NFS_NFS4FILELAYOUT_H */
OpenPOWER on IntegriCloud