summaryrefslogtreecommitdiffstats
path: root/drivers
diff options
context:
space:
mode:
authorNeilBrown <neilb@suse.de>2006-10-06 00:44:04 -0700
committerLinus Torvalds <torvalds@g5.osdl.org>2006-10-06 08:53:41 -0700
commit5842730de179405d80649231faa0b3f254477434 (patch)
treeb7597063929ad3e0536d22077bde53b6d5ad13d4 /drivers
parentec5a19dd935eb3793e1f6ed491e8035b3d7b1df9 (diff)
downloadtalos-obmc-linux-5842730de179405d80649231faa0b3f254477434.tar.gz
talos-obmc-linux-5842730de179405d80649231faa0b3f254477434.zip
[PATCH] md: fix bug where new drives added to an md array sometimes don't sync properly
This fixes a bug introduced in 2.6.18. If a drive is added to a raid1 using older tools (mdadm-1.x or raidtools) then it will be included in the array without any resync happening. It has been submitted for 2.6.18.1. Signed-off-by: Neil Brown <neilb@suse.de> Cc: <stable@kernel.org> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/md/md.c1
1 files changed, 1 insertions, 0 deletions
diff --git a/drivers/md/md.c b/drivers/md/md.c
index cb8281605be8..57fa64f93e5f 100644
--- a/drivers/md/md.c
+++ b/drivers/md/md.c
@@ -3849,6 +3849,7 @@ static int hot_add_disk(mddev_t * mddev, dev_t dev)
}
clear_bit(In_sync, &rdev->flags);
rdev->desc_nr = -1;
+ rdev->saved_raid_disk = -1;
err = bind_rdev_to_array(rdev, mddev);
if (err)
goto abort_export;