summaryrefslogtreecommitdiffstats
path: root/drivers/scsi/sun3_scsi.c
diff options
context:
space:
mode:
authorFinn Thain <fthain@telegraphics.com.au>2014-11-12 16:11:58 +1100
committerChristoph Hellwig <hch@lst.de>2014-11-20 09:11:08 +0100
commit8c32513bd395dc5d382e4883097482567cf8bbc5 (patch)
treef603eda2bb0ccf602c88b69e7fb9f6fb6cb947c7 /drivers/scsi/sun3_scsi.c
parent270ac2c290ad8b83c92ceeed07aaf49ec5807851 (diff)
downloadtalos-obmc-linux-8c32513bd395dc5d382e4883097482567cf8bbc5.tar.gz
talos-obmc-linux-8c32513bd395dc5d382e4883097482567cf8bbc5.zip
ncr5380: Cleanup host info() methods
If the host->info() method is not set, then host->name is used by default. For atari_scsi, that is exactly the same text. So remove the redundant info() method. Keep sun3_scsi.c in line with atari_scsi. Some NCR5380 drivers return an empty string from the info() method (arm/cumana_1.c arm/oak.c mac_scsi.c) while other drivers use the default (dmx3191d dtc.c g_NCR5380.c pas16.c t128.c). Implement a common info() method to replace a lot of duplicated code which the various drivers use to announce the same information. This replaces most of the (deprecated) show_info() output and all of the NCR5380_print_info() output. This also eliminates a bunch of code in g_NCR5380 which just duplicates functionality in the core driver. Signed-off-by: Finn Thain <fthain@telegraphics.com.au> Reviewed-by: Hannes Reinecke <hare@suse.de> Tested-by: Michael Schmitz <schmitzmic@gmail.com> Signed-off-by: Christoph Hellwig <hch@lst.de>
Diffstat (limited to 'drivers/scsi/sun3_scsi.c')
-rw-r--r--drivers/scsi/sun3_scsi.c18
1 files changed, 0 insertions, 18 deletions
diff --git a/drivers/scsi/sun3_scsi.c b/drivers/scsi/sun3_scsi.c
index 3e6386252953..9bae5f6122a7 100644
--- a/drivers/scsi/sun3_scsi.c
+++ b/drivers/scsi/sun3_scsi.c
@@ -286,19 +286,6 @@ static int __init sun3scsi_detect(struct scsi_host_template *tpnt)
#endif
}
- pr_info("scsi%d: %s at port %lX irq", instance->host_no,
- tpnt->proc_name, instance->io_port);
- if (instance->irq == NO_IRQ)
- printk ("s disabled");
- else
- printk (" %d", instance->irq);
- printk(" options CAN_QUEUE=%d CMD_PER_LUN=%d release=%d",
- instance->can_queue, instance->cmd_per_lun,
- SUN3SCSI_PUBLIC_RELEASE);
- printk("\nscsi%d:", instance->host_no);
- NCR5380_print_options(instance);
- printk("\n");
-
dregs->csr = 0;
udelay(SUN3_DMA_DELAY);
dregs->csr = CSR_SCSI | CSR_FIFO | CSR_INTR;
@@ -380,11 +367,6 @@ static void sun3_scsi_reset_boot(struct Scsi_Host *instance)
}
#endif
-static const char *sun3scsi_info(struct Scsi_Host *spnt)
-{
- return "";
-}
-
// safe bits for the CSR
#define CSR_GOOD 0x060f
OpenPOWER on IntegriCloud