summaryrefslogtreecommitdiffstats
path: root/drivers/scsi/storvsc_drv.c
diff options
context:
space:
mode:
authorLong Li <longli@microsoft.com>2016-12-14 18:46:01 -0800
committerMartin K. Petersen <martin.petersen@oracle.com>2017-01-05 00:21:11 -0500
commit3cd6d3d9b1abab8dcdf0800224ce26daac24eea2 (patch)
tree633aab5801ea940ec25ef3b7e79c6e90ef30e0a5 /drivers/scsi/storvsc_drv.c
parentd86adf482b843b3a58a9ec3b7c1ccdbf7c705db1 (diff)
downloadtalos-obmc-linux-3cd6d3d9b1abab8dcdf0800224ce26daac24eea2.tar.gz
talos-obmc-linux-3cd6d3d9b1abab8dcdf0800224ce26daac24eea2.zip
scsi: storvsc: use tagged SRB requests if supported by the device
Properly set SRB flags when hosting device supports tagged queuing. This patch improves the performance on Fiber Channel disks. Signed-off-by: Long Li <longli@microsoft.com> Reviewed-by: K. Y. Srinivasan <kys@microsoft.com> Signed-off-by: K. Y. Srinivasan <kys@microsoft.com> Cc: <stable@vger.kernel.org> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Diffstat (limited to 'drivers/scsi/storvsc_drv.c')
-rw-r--r--drivers/scsi/storvsc_drv.c9
1 files changed, 9 insertions, 0 deletions
diff --git a/drivers/scsi/storvsc_drv.c b/drivers/scsi/storvsc_drv.c
index 63f6b1ad57c5..320938720544 100644
--- a/drivers/scsi/storvsc_drv.c
+++ b/drivers/scsi/storvsc_drv.c
@@ -136,6 +136,8 @@ struct hv_fc_wwn_packet {
#define SRB_FLAGS_PORT_DRIVER_RESERVED 0x0F000000
#define SRB_FLAGS_CLASS_DRIVER_RESERVED 0xF0000000
+#define SP_UNTAGGED ((unsigned char) ~0)
+#define SRB_SIMPLE_TAG_REQUEST 0x20
/*
* Platform neutral description of a scsi request -
@@ -1549,6 +1551,13 @@ static int storvsc_queuecommand(struct Scsi_Host *host, struct scsi_cmnd *scmnd)
vm_srb->win8_extension.srb_flags |=
SRB_FLAGS_DISABLE_SYNCH_TRANSFER;
+ if (scmnd->device->tagged_supported) {
+ vm_srb->win8_extension.srb_flags |=
+ (SRB_FLAGS_QUEUE_ACTION_ENABLE | SRB_FLAGS_NO_QUEUE_FREEZE);
+ vm_srb->win8_extension.queue_tag = SP_UNTAGGED;
+ vm_srb->win8_extension.queue_action = SRB_SIMPLE_TAG_REQUEST;
+ }
+
/* Build the SRB */
switch (scmnd->sc_data_direction) {
case DMA_TO_DEVICE:
OpenPOWER on IntegriCloud