regulator: improved mode error checks
Minor bugfixes in handling of regulator modes: - have the routine verifying regulator modes check against the set of legal modes (!); - have regulator_set_optimum_mode() verify the return value of regulator_ops.get_optimum_mode(), like drms_uA_update(); - one call to regulator_ops.set_mode() treated zero as a failure code; make this consistent with other callers. Both regulator_set_mode() and regulator_set_optimum_mode() now require valid_ops_mask to include REGULATOR_CHANGE_MODE; that seems like a bugfix too. Signed-off-by: David Brownell <dbrownell@users.sourceforge.net> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
Diffstat (limited to 'drivers/regulator')
-rw-r--r--drivers/regulator/core.c15
1 files changed, 13 insertions, 2 deletions
diff --git a/drivers/regulator/core.c b/drivers/regulator/core.c
index c2b7ec901036..686dfa990726 100644
--- a/drivers/regulator/core.c
+++ b/drivers/regulator/core.c
@@ -174,6 +174,16 @@ static int regulator_check_current_limit(struct regulator_dev *rdev,
/* operating mode constraint check */
static int regulator_check_mode(struct regulator_dev *rdev, int mode)
{
+ switch (mode) {
+ case REGULATOR_MODE_FAST:
+ case REGULATOR_MODE_NORMAL:
+ case REGULATOR_MODE_IDLE:
+ case REGULATOR_MODE_STANDBY:
+ break;
+ default:
+ return -EINVAL;
+ }
+
if (!rdev->constraints) {
printk(KERN_ERR "%s: no constraints for %s\n", __func__,
rdev->desc->name);
@@ -1494,7 +1504,8 @@ int regulator_set_optimum_mode(struct regulator *regulator, int uA_load)
mode = rdev->desc->ops->get_optimum_mode(rdev,
input_uV, output_uV,
total_uA_load);
- if (ret <= 0) {
+ ret = regulator_check_mode(rdev, mode);
+ if (ret < 0) {
printk(KERN_ERR "%s: failed to get optimum mode for %s @"
" %d uA %d -> %d uV\n", __func__, rdev->desc->name,
total_uA_load, input_uV, output_uV);
@@ -1502,7 +1513,7 @@ int regulator_set_optimum_mode(struct regulator *regulator, int uA_load)
}
ret = rdev->desc->ops->set_mode(rdev, mode);
- if (ret <= 0) {
+ if (ret < 0) {
printk(KERN_ERR "%s: failed to set optimum mode %x for %s\n",
__func__, mode, rdev->desc->name);
goto out;