summaryrefslogtreecommitdiffstats
path: root/drivers/net/ethernet/emulex/benet/be_cmds.c
diff options
context:
space:
mode:
authorSuresh Reddy <Suresh.Reddy@emulex.com>2015-07-10 05:32:50 -0400
committerDavid S. Miller <davem@davemloft.net>2015-07-10 23:24:30 -0700
commit9c8559750cd7b7936dd38810fc2110fc91d7d527 (patch)
tree6838d849e43444c5beb70b2e4b1de0d690926656 /drivers/net/ethernet/emulex/benet/be_cmds.c
parent8af65c2f4deeb02a128c5cf29fa351b70bf16424 (diff)
downloadtalos-obmc-linux-9c8559750cd7b7936dd38810fc2110fc91d7d527.tar.gz
talos-obmc-linux-9c8559750cd7b7936dd38810fc2110fc91d7d527.zip
be2net: make SET_LOOPBACK_MODE cmd asynchrounous
The SET_LOOPBACK_MODE command is always issued from ethtool only in a process context. So, while waiting for the cmd to complete, the driver can sleep instead of holding spin_lock_bh() on the mcc_lock. This is done by calling be_mcc_notify() instead of be_mcc_notify_wait() (that returns only after the cmd completes while the MCCQ is locked). Signed-off-by: Suresh Reddy <suresh.reddy@avagotech.com> Signed-off-by: Sathya Perla <sathya.perla@avagotech.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/ethernet/emulex/benet/be_cmds.c')
-rw-r--r--drivers/net/ethernet/emulex/benet/be_cmds.c23
1 files changed, 20 insertions, 3 deletions
diff --git a/drivers/net/ethernet/emulex/benet/be_cmds.c b/drivers/net/ethernet/emulex/benet/be_cmds.c
index 93934d347a23..ecad46f79653 100644
--- a/drivers/net/ethernet/emulex/benet/be_cmds.c
+++ b/drivers/net/ethernet/emulex/benet/be_cmds.c
@@ -172,6 +172,12 @@ static void be_async_cmd_process(struct be_adapter *adapter,
return;
}
+ if (opcode == OPCODE_LOWLEVEL_SET_LOOPBACK_MODE &&
+ subsystem == CMD_SUBSYSTEM_LOWLEVEL) {
+ complete(&adapter->et_cmd_compl);
+ return;
+ }
+
if ((opcode == OPCODE_COMMON_WRITE_FLASHROM ||
opcode == OPCODE_COMMON_WRITE_OBJECT) &&
subsystem == CMD_SUBSYSTEM_COMMON) {
@@ -2600,7 +2606,7 @@ int be_cmd_set_loopback(struct be_adapter *adapter, u8 port_num,
wrb = wrb_from_mccq(adapter);
if (!wrb) {
status = -EBUSY;
- goto err;
+ goto err_unlock;
}
req = embedded_payload(wrb);
@@ -2614,8 +2620,19 @@ int be_cmd_set_loopback(struct be_adapter *adapter, u8 port_num,
req->loopback_type = loopback_type;
req->loopback_state = enable;
- status = be_mcc_notify_wait(adapter);
-err:
+ status = be_mcc_notify(adapter);
+ if (status)
+ goto err_unlock;
+
+ spin_unlock_bh(&adapter->mcc_lock);
+
+ if (!wait_for_completion_timeout(&adapter->et_cmd_compl,
+ msecs_to_jiffies(SET_LB_MODE_TIMEOUT)))
+ status = -ETIMEDOUT;
+
+ return status;
+
+err_unlock:
spin_unlock_bh(&adapter->mcc_lock);
return status;
}
OpenPOWER on IntegriCloud