md/raid5: Fix livelock when array is both resyncing and degraded.
Commit a7854487cd7128a30a7f4f5259de9f67d5efb95f:
md: When RAID5 is dirty, force reconstruct-write instead of read-modify-write.
Causes an RCW cycle to be forced even when the array is degraded.
A degraded array cannot support RCW as that requires reading all data
blocks, and one may be missing.
Forcing an RCW when it is not possible causes a live-lock and the code
spins, repeatedly deciding to do something that cannot succeed.
So change the condition to only force RCW on non-degraded arrays.
Reported-by: Manibalan P <pmanibalan@amiindia.co.in>
Bisected-by: Jes Sorensen <Jes.Sorensen@redhat.com>
Tested-by: Jes Sorensen <Jes.Sorensen@redhat.com>
Signed-off-by: NeilBrown <neilb@suse.de>
Fixes: a7854487cd7128a30a7f4f5259de9f67d5efb95f
Cc: stable@vger.kernel.org (v3.7+)
Diffstat (limited to 'drivers/md')
-rw-r--r-- | drivers/md/raid5.c | 3 |
1 files changed, 2 insertions, 1 deletions
diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c index aa76865b804b..e75d48c0421a 100644 --- a/drivers/md/raid5.c +++ b/drivers/md/raid5.c @@ -3170,7 +3170,8 @@ static void handle_stripe_dirtying(struct r5conf *conf, * generate correct data from the parity. */ if (conf->max_degraded == 2 || - (recovery_cp < MaxSector && sh->sector >= recovery_cp)) { + (recovery_cp < MaxSector && sh->sector >= recovery_cp && + s->failed == 0)) { /* Calculate the real rcw later - for now make it * look like rcw is cheaper */ |