md/raid5: Fix livelock when array is both resyncing and degraded.
Commit a7854487cd7128a30a7f4f5259de9f67d5efb95f: md: When RAID5 is dirty, force reconstruct-write instead of read-modify-write. Causes an RCW cycle to be forced even when the array is degraded. A degraded array cannot support RCW as that requires reading all data blocks, and one may be missing. Forcing an RCW when it is not possible causes a live-lock and the code spins, repeatedly deciding to do something that cannot succeed. So change the condition to only force RCW on non-degraded arrays. Reported-by: Manibalan P <pmanibalan@amiindia.co.in> Bisected-by: Jes Sorensen <Jes.Sorensen@redhat.com> Tested-by: Jes Sorensen <Jes.Sorensen@redhat.com> Signed-off-by: NeilBrown <neilb@suse.de> Fixes: a7854487cd7128a30a7f4f5259de9f67d5efb95f Cc: stable@vger.kernel.org (v3.7+)
Diffstat (limited to 'drivers/md')
-rw-r--r--drivers/md/raid5.c3
1 files changed, 2 insertions, 1 deletions
diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c
index aa76865b804b..e75d48c0421a 100644
--- a/drivers/md/raid5.c
+++ b/drivers/md/raid5.c
@@ -3170,7 +3170,8 @@ static void handle_stripe_dirtying(struct r5conf *conf,
* generate correct data from the parity.
*/
if (conf->max_degraded == 2 ||
- (recovery_cp < MaxSector && sh->sector >= recovery_cp)) {
+ (recovery_cp < MaxSector && sh->sector >= recovery_cp &&
+ s->failed == 0)) {
/* Calculate the real rcw later - for now make it
* look like rcw is cheaper
*/