authorChristian König <christian.koenig@amd.com>2016-02-26 16:18:26 +0100
committerAlex Deucher <alexander.deucher@amd.com>2016-02-29 11:33:46 -0500
commit4ff37a83f19dab4e67299325ee22e98346eee857 (patch)
treea8778a8fb2140caebf7cf8f2fd080e9828606c90 /drivers/gpu/drm/amd/amdgpu/amdgpu_ib.c
parentce22c4bfdf70c03e9308751df5c2bf78b79a893f (diff)
downloadtalos-obmc-linux-4ff37a83f19dab4e67299325ee22e98346eee857.tar.gz
talos-obmc-linux-4ff37a83f19dab4e67299325ee22e98346eee857.zip
drm/amdgpu: fix VM faults caused by vm_grab_id() v4
The owner must be per ring as long as we don't support sharing VMIDs per process. Also move the assigned VMID and page directory address into the IB structure. v3: assign the VMID to all IBs, not just the first one. v4: use correct pointer for owner Signed-off-by: Christian König <christian.koenig@amd.com> Reviewed-by: Chunming Zhou <david1.zhou@amd.com> Acked-by: Alex Deucher <alexander.deucher@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
Diffstat (limited to 'drivers/gpu/drm/amd/amdgpu/amdgpu_ib.c')
-rw-r--r--drivers/gpu/drm/amd/amdgpu/amdgpu_ib.c7
1 files changed, 4 insertions, 3 deletions
diff --git a/drivers/gpu/drm/amd/amdgpu/amdgpu_ib.c b/drivers/gpu/drm/amd/amdgpu/amdgpu_ib.c
index b5bdd5d59b58..db14a7bbb8f4 100644
--- a/drivers/gpu/drm/amd/amdgpu/amdgpu_ib.c
+++ b/drivers/gpu/drm/amd/amdgpu/amdgpu_ib.c
@@ -75,6 +75,7 @@ int amdgpu_ib_get(struct amdgpu_device *adev, struct amdgpu_vm *vm,
}
ib->vm = vm;
+ ib->vm_id = 0;
return 0;
}
@@ -139,7 +140,7 @@ int amdgpu_ib_schedule(struct amdgpu_ring *ring, unsigned num_ibs,
return -EINVAL;
}
- if (vm && !ibs->grabbed_vmid) {
+ if (vm && !ibs->vm_id) {
dev_err(adev->dev, "VM IB without ID\n");
return -EINVAL;
}
@@ -152,10 +153,10 @@ int amdgpu_ib_schedule(struct amdgpu_ring *ring, unsigned num_ibs,
if (vm) {
/* do context switch */
- amdgpu_vm_flush(ring, vm, last_vm_update);
+ amdgpu_vm_flush(ring, ib->vm_id, ib->vm_pd_addr);
if (ring->funcs->emit_gds_switch)
- amdgpu_ring_emit_gds_switch(ring, ib->vm->ids[ring->idx].id,
+ amdgpu_ring_emit_gds_switch(ring, ib->vm_id,
ib->gds_base, ib->gds_size,
ib->gws_base, ib->gws_size,
ib->oa_base, ib->oa_size);