summaryrefslogtreecommitdiffstats
path: root/drivers/cpufreq
diff options
context:
space:
mode:
authorViresh Kumar <viresh.kumar@linaro.org>2017-03-14 10:48:31 +0530
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>2017-03-16 00:14:31 +0100
commit19678ffb9fd6f216f530714e62fb469a961874db (patch)
tree4d626647ea5a8b97b839925354f6697243ec90e9 /drivers/cpufreq
parent6f19363503541ee6020d35b468a998c213bace36 (diff)
downloadtalos-obmc-linux-19678ffb9fd6f216f530714e62fb469a961874db.tar.gz
talos-obmc-linux-19678ffb9fd6f216f530714e62fb469a961874db.zip
cpufreq: dbx500: Manage cooling device from cpufreq driver
The best place to register the CPU cooling device is from the cpufreq driver as we would know if all the resources are already available or not. That's what is done for the cpufreq-dt.c driver as well. The cpu-cooling driver for dbx500 platform was just (un)registering with the thermal framework and that can be handled easily by the cpufreq driver as well and in proper sequence as well. Get rid of the cooling driver and its its users and manage everything from the cpufreq driver instead. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Tested-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r--drivers/cpufreq/dbx500-cpufreq.c20
1 files changed, 20 insertions, 0 deletions
diff --git a/drivers/cpufreq/dbx500-cpufreq.c b/drivers/cpufreq/dbx500-cpufreq.c
index 5c3ec1dd4921..3575b82210ba 100644
--- a/drivers/cpufreq/dbx500-cpufreq.c
+++ b/drivers/cpufreq/dbx500-cpufreq.c
@@ -11,6 +11,7 @@
#include <linux/module.h>
#include <linux/kernel.h>
#include <linux/cpufreq.h>
+#include <linux/cpu_cooling.h>
#include <linux/delay.h>
#include <linux/slab.h>
#include <linux/platform_device.h>
@@ -18,6 +19,7 @@
static struct cpufreq_frequency_table *freq_table;
static struct clk *armss_clk;
+static struct thermal_cooling_device *cdev;
static int dbx500_cpufreq_target(struct cpufreq_policy *policy,
unsigned int index)
@@ -32,6 +34,22 @@ static int dbx500_cpufreq_init(struct cpufreq_policy *policy)
return cpufreq_generic_init(policy, freq_table, 20 * 1000);
}
+static int dbx500_cpufreq_exit(struct cpufreq_policy *policy)
+{
+ if (!IS_ERR(cdev))
+ cpufreq_cooling_unregister(cdev);
+ return 0;
+}
+
+static void dbx500_cpufreq_ready(struct cpufreq_policy *policy)
+{
+ cdev = cpufreq_cooling_register(policy->cpus);
+ if (IS_ERR(cdev))
+ pr_err("Failed to register cooling device %ld\n", PTR_ERR(cdev));
+ else
+ pr_info("Cooling device registered: %s\n", cdev->type);
+}
+
static struct cpufreq_driver dbx500_cpufreq_driver = {
.flags = CPUFREQ_STICKY | CPUFREQ_CONST_LOOPS |
CPUFREQ_NEED_INITIAL_FREQ_CHECK,
@@ -39,6 +57,8 @@ static struct cpufreq_driver dbx500_cpufreq_driver = {
.target_index = dbx500_cpufreq_target,
.get = cpufreq_generic_get,
.init = dbx500_cpufreq_init,
+ .exit = dbx500_cpufreq_exit,
+ .ready = dbx500_cpufreq_ready,
.name = "DBX500",
.attr = cpufreq_generic_attr,
};
OpenPOWER on IntegriCloud