summaryrefslogtreecommitdiffstats
path: root/Documentation/thermal
diff options
context:
space:
mode:
authorJavi Merino <javi.merino@arm.com>2015-03-26 15:53:02 +0000
committerEduardo Valentin <edubezval@gmail.com>2015-05-04 21:27:54 -0700
commit9f38271c6f82a577d9fdab27aaf2e1c55ae5cf73 (patch)
treea286309ec30fc92c3422f3bf9bcd1d053ffdf4c6 /Documentation/thermal
parent0cdf97e1ad8d796313de051528f06c1b16f3a679 (diff)
downloadtalos-obmc-linux-9f38271c6f82a577d9fdab27aaf2e1c55ae5cf73.tar.gz
talos-obmc-linux-9f38271c6f82a577d9fdab27aaf2e1c55ae5cf73.zip
thermal: export thermal_zone_parameters to sysfs
It's useful for tuning to be able to edit thermal_zone_parameters from userspace. Export them to the thermal_zone sysfs so that they can be easily changed. Cc: Zhang Rui <rui.zhang@intel.com> Cc: Eduardo Valentin <edubezval@gmail.com> Signed-off-by: Javi Merino <javi.merino@arm.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'Documentation/thermal')
-rw-r--r--Documentation/thermal/sysfs-api.txt52
1 files changed, 52 insertions, 0 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index fc7dfe10778b..7d44d7f1a71b 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -184,6 +184,12 @@ Thermal zone device sys I/F, created once it's registered:
|---trip_point_[0-*]_type: Trip point type
|---trip_point_[0-*]_hyst: Hysteresis value for this trip point
|---emul_temp: Emulated temperature set node
+ |---sustainable_power: Sustainable dissipatable power
+ |---k_po: Proportional term during temperature overshoot
+ |---k_pu: Proportional term during temperature undershoot
+ |---k_i: PID's integral term in the power allocator gov
+ |---k_d: PID's derivative term in the power allocator
+ |---integral_cutoff: Offset above which errors are accumulated
Thermal cooling device sys I/F, created once it's registered:
/sys/class/thermal/cooling_device[0-*]:
@@ -307,6 +313,52 @@ emul_temp
because userland can easily disable the thermal policy by simply
flooding this sysfs node with low temperature values.
+sustainable_power
+ An estimate of the sustained power that can be dissipated by
+ the thermal zone. Used by the power allocator governor. For
+ more information see Documentation/thermal/power_allocator.txt
+ Unit: milliwatts
+ RW, Optional
+
+k_po
+ The proportional term of the power allocator governor's PID
+ controller during temperature overshoot. Temperature overshoot
+ is when the current temperature is above the "desired
+ temperature" trip point. For more information see
+ Documentation/thermal/power_allocator.txt
+ RW, Optional
+
+k_pu
+ The proportional term of the power allocator governor's PID
+ controller during temperature undershoot. Temperature undershoot
+ is when the current temperature is below the "desired
+ temperature" trip point. For more information see
+ Documentation/thermal/power_allocator.txt
+ RW, Optional
+
+k_i
+ The integral term of the power allocator governor's PID
+ controller. This term allows the PID controller to compensate
+ for long term drift. For more information see
+ Documentation/thermal/power_allocator.txt
+ RW, Optional
+
+k_d
+ The derivative term of the power allocator governor's PID
+ controller. For more information see
+ Documentation/thermal/power_allocator.txt
+ RW, Optional
+
+integral_cutoff
+ Temperature offset from the desired temperature trip point
+ above which the integral term of the power allocator
+ governor's PID controller starts accumulating errors. For
+ example, if integral_cutoff is 0, then the integral term only
+ accumulates error when temperature is above the desired
+ temperature trip point. For more information see
+ Documentation/thermal/power_allocator.txt
+ RW, Optional
+
*****************************