summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon
diff options
context:
space:
mode:
authorGuenter Roeck <linux@roeck-us.net>2014-01-11 10:28:05 -0800
committerGuenter Roeck <linux@roeck-us.net>2014-03-03 08:01:03 -0800
commit6700ce035f830149d48c270d84736debfb67179e (patch)
treebf493ef3c9cd307caed3f6295a5d7cfd1a09ff2d /Documentation/hwmon
parent69e1ded651ee31c8a570d58647902a55806d0db8 (diff)
downloadtalos-obmc-linux-6700ce035f830149d48c270d84736debfb67179e.tar.gz
talos-obmc-linux-6700ce035f830149d48c270d84736debfb67179e.zip
hwmon: Driver for Linear Technologies LTC2945
LTC2945 is a system monitor that measures current, voltage, and power. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/ltc294584
1 files changed, 84 insertions, 0 deletions
diff --git a/Documentation/hwmon/ltc2945 b/Documentation/hwmon/ltc2945
new file mode 100644
index 000000000000..f8d0f7f19adb
--- /dev/null
+++ b/Documentation/hwmon/ltc2945
@@ -0,0 +1,84 @@
+Kernel driver ltc2945
+=====================
+
+Supported chips:
+ * Linear Technology LTC2945
+ Prefix: 'ltc2945'
+ Addresses scanned: -
+ Datasheet:
+ http://cds.linear.com/docs/en/datasheet/2945fa.pdf
+
+Author: Guenter Roeck <linux@roeck-us.net>
+
+
+Description
+-----------
+
+The LTC2945 is a rail-to-rail system monitor that measures current, voltage,
+and power consumption.
+
+
+Usage Notes
+-----------
+
+This driver does not probe for LTC2945 devices, since there is no register
+which can be safely used to identify the chip. You will have to instantiate
+the devices explicitly.
+
+Example: the following will load the driver for an LTC2945 at address 0x10
+on I2C bus #1:
+$ modprobe ltc2945
+$ echo ltc2945 0x10 > /sys/bus/i2c/devices/i2c-1/new_device
+
+
+Sysfs entries
+-------------
+
+Voltage readings provided by this driver are reported as obtained from the ADC
+registers. If a set of voltage divider resistors is installed, calculate the
+real voltage by multiplying the reported value with (R1+R2)/R2, where R1 is the
+value of the divider resistor against the measured voltage and R2 is the value
+of the divider resistor against Ground.
+
+Current reading provided by this driver is reported as obtained from the ADC
+Current Sense register. The reported value assumes that a 1 mOhm sense resistor
+is installed. If a different sense resistor is installed, calculate the real
+current by dividing the reported value by the sense resistor value in mOhm.
+
+in1_input VIN voltage (mV). Voltage is measured either at
+ SENSE+ or VDD pin depending on chip configuration.
+in1_min Undervoltage threshold
+in1_max Overvoltage threshold
+in1_lowest Lowest measured voltage
+in1_highest Highest measured voltage
+in1_reset_history Write 1 to reset in1 history
+in1_min_alarm Undervoltage alarm
+in1_max_alarm Overvoltage alarm
+
+in2_input ADIN voltage (mV)
+in2_min Undervoltage threshold
+in2_max Overvoltage threshold
+in2_lowest Lowest measured voltage
+in2_highest Highest measured voltage
+in2_reset_history Write 1 to reset in2 history
+in2_min_alarm Undervoltage alarm
+in2_max_alarm Overvoltage alarm
+
+curr1_input SENSE current (mA)
+curr1_min Undercurrent threshold
+curr1_max Overcurrent threshold
+curr1_lowest Lowest measured current
+curr1_highest Highest measured current
+curr1_reset_history Write 1 to reset curr1 history
+curr1_min_alarm Undercurrent alarm
+curr1_max_alarm Overcurrent alarm
+
+power1_input Power (in uW). Power is calculated based on SENSE+/VDD
+ voltage or ADIN voltage depending on chip configuration.
+power1_min Low lower threshold
+power1_max High power threshold
+power1_input_lowest Historical minimum power use
+power1_input_highest Historical maximum power use
+power1_reset_history Write 1 to reset power1 history
+power1_min_alarm Low power alarm
+power1_max_alarm High power alarm
OpenPOWER on IntegriCloud