[PATCH] sk98lin: remove PCI id info for cards for conflicting devices
Fix PCI device id issues with sk98lin driver. 1. DLINK 530-T card has no Vital Product Data (VPD) area so the sk98lin driver won't work. (skge does however) 2. Remove commented out Yukon2 stuff 3. Restrict Linksys card to revisions that don't conflict with r8169 version. Signed-off-by: Stephen Hemminger <shemminger@osdl.org> Signed-off-by: Jeff Garzik <jgarzik@pobox.com>
-rw-r--r--drivers/net/sk98lin/skge.c12
1 files changed, 5 insertions, 7 deletions
diff --git a/drivers/net/sk98lin/skge.c b/drivers/net/sk98lin/skge.c
index 6ee4771addf1..2e72d79a143c 100644
--- a/drivers/net/sk98lin/skge.c
+++ b/drivers/net/sk98lin/skge.c
@@ -5216,17 +5216,15 @@ static struct pci_device_id skge_pci_tbl[] = {
{ PCI_VENDOR_ID_3COM, 0x80eb, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ PCI_VENDOR_ID_SYSKONNECT, 0x4300, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ PCI_VENDOR_ID_SYSKONNECT, 0x4320, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
- { PCI_VENDOR_ID_DLINK, 0x4c00, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
+/* DLink card does not have valid VPD so this driver gags
+ * { PCI_VENDOR_ID_DLINK, 0x4c00, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
+ */
{ PCI_VENDOR_ID_MARVELL, 0x4320, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
-#if 0 /* don't handle Yukon2 cards at the moment -- mlindner@syskonnect.de */
- { PCI_VENDOR_ID_MARVELL, 0x4360, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
- { PCI_VENDOR_ID_MARVELL, 0x4361, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
-#endif
{ PCI_VENDOR_ID_MARVELL, 0x5005, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
{ PCI_VENDOR_ID_CNET, 0x434e, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
- { PCI_VENDOR_ID_LINKSYS, 0x1032, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
+ { PCI_VENDOR_ID_LINKSYS, 0x1032, PCI_ANY_ID, 0x0015, },
{ PCI_VENDOR_ID_LINKSYS, 0x1064, PCI_ANY_ID, PCI_ANY_ID, 0, 0, 0 },
- { 0, }
+ { 0 }
};
MODULE_DEVICE_TABLE(pci, skge_pci_tbl);