<!-- IBM_PROLOG_BEGIN_TAG -->
<!-- This is an automatically generated prolog. -->
<!-- -->
<!-- $Source: src/usr/hwpf/hwp/core_activate/proc_stop_deadman_timer/proc_stop_deadman_timer_errors.xml $ -->
<!-- -->
<!-- IBM CONFIDENTIAL -->
<!-- -->
<!-- COPYRIGHT International Business Machines Corp. 2012,2014 -->
<!-- -->
<!-- p1 -->
<!-- -->
<!-- Object Code Only (OCO) source materials -->
<!-- Licensed Internal Code Source Materials -->
<!-- IBM HostBoot Licensed Internal Code -->
<!-- -->
<!-- The source code for this program is not published or otherwise -->
<!-- divested of its trade secrets, irrespective of what has been -->
<!-- deposited with the U.S. Copyright Office. -->
<!-- -->
<!-- Origin: 30 -->
<!-- -->
<!-- IBM_PROLOG_END_TAG -->
<!-- $Id: proc_stop_deadman_timer_errors.xml,v 1.6 2014/02/10 04:37:29 stillgs Exp $ -->
<!-- Error definitions for proc_stop_deadman_timer procedure -->
<hwpErrors>
<!-- *********************************************************************** -->
<hwpError>
<rc>RC_PROC_STOP_DEADMAN_TIMER_BAD_ISTEP_NUM</rc>
<description>
Procedure: proc_stop_deadman_timer
The SBE is not at the correct istep number to stop the deadman timer
</description>
<collectRegisterFfdc>
<id>REG_FFDC_PROC_STATUS_AND_SBE_VITAL_REGISTERS</id>
<id>REG_FFDC_PROC_SBE_REGISTERS</id>
<id>REG_FFDC_PROC_SLW_REGISTERS</id>
<id>REG_FFDC_PROC_SLW_FIR_REGISTERS</id>
<id>REG_FFDC_PROC_SLW_PMC_REGISTERS</id>
<id>REG_FFDC_PROC_SLW_PBA_REGISTERS</id>
<target>CHIP_IN_ERROR</target>
</collectRegisterFfdc>
<collectRegisterFfdc>
<id>REG_FFDC_PROC_SLW_PCBS_REGISTERS</id>
<basedOnPresentChildren>
<target>CHIP_IN_ERROR</target>
<childType>TARGET_TYPE_EX_CHIPLET</childType>
<childPosOffsetMultiplier>0x01000000</childPosOffsetMultiplier>
</basedOnPresentChildren>
</collectRegisterFfdc>
<ffdc>SBE_VITAL</ffdc>
<callout>
<procedure>CODE</procedure>
<priority>HIGH</priority>
</callout>
</hwpError>
<!-- *********************************************************************** -->
<hwpError>
<rc>RC_PROC_STOP_DEADMAN_TIMER_BAD_SUBSTEP_NUM</rc>
<description>
Procedure: proc_stop_deadman_timer
The SBE is not at the correct substep number to stop the deadman timer
</description>
<collectRegisterFfdc>
<id>REG_FFDC_PROC_STATUS_AND_SBE_VITAL_REGISTERS</id>
<id>REG_FFDC_PROC_SBE_REGISTERS</id>
<id>REG_FFDC_PROC_SLW_REGISTERS</id>
<id>REG_FFDC_PROC_SLW_FIR_REGISTERS</id>
<id>REG_FFDC_PROC_SLW_PMC_REGISTERS</id>
<id>REG_FFDC_PROC_SLW_PBA_REGISTERS</id>
<target>CHIP_IN_ERROR</target>
</collectRegisterFfdc>
<collectRegisterFfdc>
<id>REG_FFDC_PROC_SLW_PCBS_REGISTERS</id>
<basedOnPresentChildren>
<target>CHIP_IN_ERROR</target>
<childType>TARGET_TYPE_EX_CHIPLET</childType>
<childPosOffsetMultiplier>0x01000000</childPosOffsetMultiplier>
</basedOnPresentChildren>
</collectRegisterFfdc>
<ffdc>SBE_VITAL</ffdc>
<callout>
<procedure>CODE</procedure>
<priority>HIGH</priority>
</callout>
</hwpError>
</hwpErrors>
|