/* IBM_PROLOG_BEGIN_TAG */
/* This is an automatically generated prolog. */
/* */
/* $Source: src/include/usr/isteps/istep12list.H $ */
/* */
/* IBM CONFIDENTIAL */
/* */
/* COPYRIGHT International Business Machines Corp. 2012,2014 */
/* */
/* p1 */
/* */
/* Object Code Only (OCO) source materials */
/* Licensed Internal Code Source Materials */
/* IBM HostBoot Licensed Internal Code */
/* */
/* The source code for this program is not published or otherwise */
/* divested of its trade secrets, irrespective of what has been */
/* deposited with the U.S. Copyright Office. */
/* */
/* Origin: 30 */
/* */
/* IBM_PROLOG_END_TAG */
#ifndef __ISTEPS_ISTEP12LIST_H
#define __ISTEPS_ISTEP12LIST_H
/**
* @file istep12list.H
*
* IStep 12 Step 12 MC Config
* IPL FLow Doc v1.35 (04/11/13)
*
* 12.1 host_collect_dimm_spd
* : Collect Master dimm SPD
* 12.2 mss_volt
* : Calc dimm voltage
* 12.3 mss_freq
* : Calc dimm frequency
* 12.4 mss_eff_config
* : Determine effective config
* 12.5 mss_attr_update
* : MSS ATTR update
*
* *****************************************************************
* THIS FILE WAS GENERATED ON 2012-03-01:1032
* *****************************************************************
*
* Please see the note in initsvcstructs.H for description of
* the ISTEPNAME macro.
*
*/
#include <initservice/initsvcstructs.H>
#include <initservice/initsvcreasoncodes.H>
// include prototypes file
#include "../../../usr/hwpf/hwp/mc_config/mc_config.H"
namespace INITSERVICE
{
const TaskInfo g_istep12[] = {
{
"", // dummy, index 0
NULL,
{ NONE, EXT_IMAGE, IPL_NOOP, false }
},
{
ISTEPNAME(12,01,"host_collect_dimm_spd"),
MC_CONFIG::call_host_collect_dimm_spd,
{ START_FN, EXT_IMAGE, NORMAL_IPL_OP, true }
},
{
ISTEPNAME(12,02,"mss_volt"),
MC_CONFIG::call_mss_volt,
{ START_FN, EXT_IMAGE, NORMAL_IPL_OP, true }
},
{
ISTEPNAME(12,03,"mss_freq"),
MC_CONFIG::call_mss_freq,
{ START_FN, EXT_IMAGE, NORMAL_IPL_OP, true }
},
{
ISTEPNAME(12,04,"mss_eff_config"),
MC_CONFIG::call_mss_eff_config,
{ START_FN, EXT_IMAGE, NORMAL_IPL_OP, true }
},
{
ISTEPNAME(12,05,"mss_attr_update"),
MC_CONFIG::call_mss_attr_update,
{ START_FN, EXT_IMAGE, NORMAL_IPL_OP, true }
},
};
const DepModInfo g_istep12Dependancies = {
{
DEP_LIB(libmc_config.so),
NULL
}
};
const ExtTaskInfo g_istep12TaskList = {
&(g_istep12[0]),
( sizeof(g_istep12)/sizeof(TaskInfo) ),
&g_istep12Dependancies
};
}; // end namespace