summaryrefslogtreecommitdiffstats
path: root/src/usr/isteps
Commit message (Collapse)AuthorAgeFilesLines
* Move VPD cache invalidation in mfgmode after we save it for HBRTDan Crowell2018-04-191-10/+13
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Inside call_host_runtime_setup() there is a call to VPD::goldenCacheInvalidate(). This function invalidates our VPD cache in PNOR in mfg-mode in order to allow manufacturing to modify serial numbers at runtime and have those settings take effect on the next boot. This has been in place since early P8 OpenPOWER. In that same function is a call to RUNTIME::populate_hbRuntimeData(). This is where we copy the Hostboot data out into mainstore for HBRT to use later on. One of those pieces of data is the VPD cache. In January a fix went in for a different issue that moved where populate_hbRuntimeData() was run, putting it *after* we clear it in mfgmode. Obviously that isn't going to work so well... This commit moves the invalidation later in the function so that it is after we save off the cache again. Change-Id: Idb482b583ecdb7bb8abcb617bae4ae786c110fea CQ: SW424124 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57469 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Corey V. Swenson <cswenson@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Adding path to use alt-memory when proc0 does not have memoryElizabeth Liner2018-04-192-18/+115
| | | | | | | | | | | | | | | | | | | | When proc0 doesn't have memory, and we are on a phyp system, we don't need to swap our master proc and we can instead just swap memory. This commit adds in the functionality to look for working memory, and send both the group and chip ID down to HWSV. Change-Id: I664d5bfcd308a4ba2ee71e3e708533c6ec9a0a71 RTC:176434 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54403 CI-Ready: Elizabeth K. Liner <eliner@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> CI-Ready: Sachin Gupta <sgupta2m@in.ibm.com> Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Use HRMOR-relative addresses for temporary PAYLOAD and HDAT memoryMike Baiocchi2018-04-181-6/+9
| | | | | | | | | | | | | | | | | | | | The FSP DMAs-via-TCEs the PAYLOAD and HDAT sections into HRMOR-relative memory on the master node. However, istep21's verifyAndMove() function was not using HRMOR-relative physical addresses and failed when node0 was not configured. These changes should address this and similar code using these address spaces. Change-Id: Idba95a97de9906ba6c0203f797b526eab694b8cf CQ:SW425130 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57357 CI-Ready: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Multinode SBE Window SupportJaymes Wilks2018-04-131-15/+28
| | | | | | | | | | | | | | | | | | | Code for SP ATTN, COMM, and SBE FFDC areas has been extended to all chips/nodes. The COMM area base address calculation is now updated to use the lowest addressable location for the master node. Change-Id: Ib02e62958a520c60e4bcc5bd9d4c4257893adbd9 RTC:189038 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56614 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Add unmask errors back to cen_framelockLuke Mulkey2018-04-131-0/+3
| | | | | | | | | | | | | | | | Change-Id: Ia05fadcd6676f2c076bad14002d6afc26953aaf9 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56027 Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: STEPHEN GLANCY <sglancy@us.ibm.com> Reviewed-by: Louis Stermole <stermole@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com> Dev-Ready: LUCAS W. MULKEY <lwmulkey@us.ibm.com> Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com> Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56037 Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
* Cleanup the fix for "zero length dump on single node systems".Rick Ward2018-04-122-5/+6
| | | | | | | | | | | | | | | | | | | | | | | The attribute, IS_MASTER_DRAWER, was being set in the function host_sys_fab_iovalid_processing() (istep 18.9), unfortunately that function is not called on single node systems. Had to reverse the logic on the previous IS_MASTER_DRAWER attribute, and make it an IS_SLAVE_DRAWER attribute. The reason is that there is a limitation (bug?) which requires hb-only, volatile attributes to have a default value of zero. Change-Id: Ib27349f18b2738b405649723cdcb11e2ec919991 CQ:SW423016 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56883 CI-Ready: Richard Ward <rward15@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Richard J. Knight <rjknight@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Remove logic to deconfigure PHBs in higher position within a pecPrachi Gupta2018-04-121-1/+1
| | | | | | | | | | | | | | | | | | | | | | | | | Current deconfig logic will deconfigure PHBs with a higher unit position under a given pec, if we were deconfiguring the PHB with a lower unit position. For example, PEC1 has PHB1 and PHB2. If we deconfigured PHB1, then we would by association deconfigure PHB2 as well. However, if we deconfigured PHB2, then we would not deconfigure PHB1. This commit removes the logic where if PHB2 is deconfigured, PHB1 is deconfigured as well. To summarize, the end result is to be able to deconfigure PHB1 or PHB2 with no effect on the other. HWPs will handle the hw limitations we have between PHBS. Change-Id: I95b31f4d051c15d896d18adf0a7f7c1b994f5928 CQ: SW417485 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56499 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Improve error handling when slave SBE fails to bootChristian Geddes2018-04-101-0/+26
| | | | | | | | | | | | | | | | If we fail to boot the slave SBE we should mark it in the istep errlog to ensure that we fail the istep and perform a reconfig loop. Change-Id: I70e67b5b3e1e35e0ee76eb1f158435ee44a436ef Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56882 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Always Lock Down SBE SEEPROM After SBE UpdateIlya Smirnov2018-04-091-5/+4
| | | | | | | | | | | | | | | | | Always force the SUL to be on, regardless of the status of security on the system. This will lock down the SBE SEEPROM and prevent writes to it. Do the setting of SUL after istep 10.2 after SBE is updated. Change-Id: If18986d709a44c8848ff31486bc1154759359c4c Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56822 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Revert "Verify frequency attributes across nodes"SWATHI M. BHATTIPROLU2018-04-094-843/+0
| | | | | | | | | | | | This reverts commit 571e1d84dfe50aaa674aa7e33abb75868b432d78. Change-Id: I8720246ef94be07ce0a37151b7209c8080320d59 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56933 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* sbe_retry_handler refactorChristian Geddes2018-04-062-28/+15
| | | | | | | | | | | | | | | | | | | Previously the sbe_retry_handler had logic and wording that assumed that it was being used to tell if the slave sbe booted or not. However this code has many more use cases then that. Also there was some indirect recursion that made the code hard to follow. With this refactor the code should be easier to follow and the vocabulary used should be more generic. Change-Id: If6520197b3dd561857e336ed89d9356c1f2601d6 CQ: SW416106 RTC: 167191 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55896 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com> Tested-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Verify frequency attributes across nodesSwathi Madhuri Bhattiprolu2018-04-054-1/+844
| | | | | | | | | | | | | | | | | | | | | | | -Existing code ensures consistency of frequency data across all modules in istep6.12. -In a multi-drawer config this data needs to be consistent across all drawers. -Master drawer sends the frequency data to all the other via IPC mechanism. -This data is compared and error is returned if there is a mismatch. Change-Id: I922d32456c9d3c4e53dae528f088dbb013c3ded9 RTC:158036 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54825 CI-Ready: SWATHI M. BHATTIPROLU <bhmadhur@in.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Richard Ward <rward15@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* zero length dump on single node systemsRick Ward2018-04-051-5/+13
| | | | | | | | | | | | | | | Quick hack to fix dumps on single node systems. Proposed fix did not work. This change forces isCurrentMasterNode() to always return true. Change-Id: I9366617d42923e5d13c0f7ea4f624e1749ad6810 CQ:SW423016 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56769 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Reset Host-mode Processor I2C Masters connected to the TPMsMike Baiocchi2018-03-301-3/+88
| | | | | | | | | | | | | | | | | This commit resets the I2C buses connected to the TPMs early in the IPL since the FSP can't do the reset for us as they lack a FSI I2C connection to the TPMs. Change-Id: I4b4893da447f3c567c04a8d0c2b647f2927ec0ab RTC:188956 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56188 Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Force checkstops for unhandled machine checksDan Crowell2018-03-291-19/+38
| | | | | | | | | | | | | | | | | | | Default MSR[ME]=0 during initial boot for bootloader and hostboot kernel Once the xscom address range has been mapped in, enable the machine check handler to force a checkstop and set MSR[ME]=1 to allow regular machine check handling CQ: SW401402 Change-Id: I104e39465e61b3b19d5c073e71271102711ae54f Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/47179 Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Close and Disable TCEs on Non-Master NodesMike Baiocchi2018-03-291-3/+123
| | | | | | | | | | | | | | | | | | During istep21.1 this commit sends a message to all non-Master nodes to close and disable their TCEs using the ipc mailbox interface to the FSP. Change-Id: I5575228c9f237025a48e0aeca23e741724ec7886 RTC:187335 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56269 CI-Ready: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Setup Node-Level Attributes for Multinode TCE SupportMike Baiocchi2018-03-262-12/+5
| | | | | | | | | | | | | | | | | | | | | This commit establishes a TCE Table and allocates the necessary TCEs for each node in a multinode (ie, Fleetwood) system. It then sets the corresponding node-level TCE attributes such that the FSP can use these TCEs for PSI Diagnostics and DMAing-via-TCEs the PAYLOAD and HDAT content. Change-Id: Ibd06675ea68a9c630987765b51fdd9db631f6425 RTC:187335 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56129 CI-Ready: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Dump collection should only be run on the master node and skipped on slaves.Rick Ward2018-03-223-139/+183
| | | | | | | | | | | | | | | | | | | Added an attribute, IS_MASTER_DRAWER, and a utility function, isCurrentMasterNode(). The attribute is set in host_sys_fab_iovalid_processing which is called during istep 18.9. isCurrentMasterNode() is called by call_host_mpipl_service() to ensure that memory dump collection is only performed on the master node during a MPIPL. Change-Id: I7fd48476c3cd7cf4697eafed6705d158a9c54dcf RTC: 116089 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55162 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Simics: Skip mem diag due to intermittent action file issuesBrian Stegmiller2018-03-201-3/+7
| | | | | | | | | | | | | | Change-Id: I113080eaa733cd9fa26079a5afa1eefda6b3bce6 CQ:SW414606 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55920 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Benjamin J. Weisenbeck <bweisenb@us.ibm.com> Reviewed-by: Caleb N. Palmer <cnpalmer@us.ibm.com> CI-Ready: Zane C. Shelley <zshelle@us.ibm.com> Reviewed-by: Zane C. Shelley <zshelle@us.ibm.com>
* Flush TMP Daemon Traces Prior to ShutdownIlya Smirnov2018-03-151-2/+4
| | | | | | | | | | | | | | | | | | We need to make sure that the TMP daemon message queue is flushed prior to shutting down the daemon. A way to do that is to send the extend separator message synchronously. That will allow for all of the traces to be logged prior to shutdown. Change-Id: Ia025e6cccbe34bbfc086f2b7213e10d4b8cf14e7 RTC:188959 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55792 Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Removing old TODO for dropped requirementDan Crowell2018-03-081-4/+2
| | | | | | | | | | | | | We are going to live with the workaround we've had in place for several years now. Change-Id: I7966f517cac2d820dc086c163a7985112e2d0fa3 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53465 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Force 25G Nvlink speed on P9N DD2.1Dean Sanner2018-03-081-1/+20
| | | | | | | | | | | | | | | | | | | | | Normally the OBUS PLL frequency is controlled via the MRW, however P9NDD2.1 has a bug that forces the OBus freq to 25G. Desire is to allow the MRW to set to a higher freq, but MRW doesn't have entries for per chip EC, so this commit just handles down leveling P9N DD2.1 (as a chip restriction) Change-Id: I542f7810a69facb919cc3889ae3ed5ca0a233445 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55195 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> CI-Ready: Dean Sanner <dsanner@us.ibm.com> CI-Ready: Corey V. Swenson <cswenson@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: ERICH J. HAUPTLI <ejhauptl@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Changes to Inband SCOM MMIO ranges for CumulusCorey Swenson2018-03-081-1/+13
| | | | | | | | | | | | | | | | | | - Add function to compress SCOM address - Old MCS target is now DMI - Add istep12 call to enable inband SCOMs - Set each DMI offset attribute in processMrw Change-Id: If5171f8da6c58404ac598047ca0177aead048771 RTC:147272 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54574 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Don't include duplicate connections when looking up xbus mappingChristian Geddes2018-03-071-5/+5
| | | | | | | | | | | | | | | | | | Previously in P8 when running the xbus scominit hwp we needed to include duplicate connections IE xbus0->xbus1 and xbus1->xbus0 when we look up what to run the xbus scominit hwp on. In p9 the HWP will initialize both ends of the xbus connection when we pass both ends into the xbus scominit hardware procedure Change-Id: I5a0a356e2086b15ee5d25cf350c9a0559ec2084b Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54726 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* changes to move configureHbrt target type to IPC path to run on slave nodesPrachi Gupta2018-03-071-8/+0
| | | | | | | | | | | | | Change-Id: Iee5e5231851e6f6389f83607da35121dbfe5a0b9 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54855 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Richard J. Knight <rjknight@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Modify putrRing code to pull rings from centaur hw imageRichard J. Knight2018-03-062-62/+173
| | | | | | | | | | | | | | | | | | -Remove hardcoded data data used for centaur init -Add code to extract RS4 compressed ring data from centaur hardware image Change-Id: If3f5faaebe384a4e0756b06f518b270c7bd2062b RTC: 171739 CMVC-Prereq: 1043602 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52063 Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Thi N. Tran <thi@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Fixed both NIMBUS and CUMULUS. They are now making the call to mss_thermal_initRoland Veloz2018-03-022-18/+56
| | | | | | | | | | | | | | | | | | Neither NIMBUS or Cumulus was making the call to mss_thermal_init. For Cumulus, the issue was trying to create a target list by getting a list of chiplets when MEMBUF is a chip. For NIMBUS, well, the code was not even there. For Nimbus a target list for the MCS, which is chiplet in this case, is created and used during the call. Change-Id: I17c4e1b12435c4dcfaa528b905d67a59962b3bca CQ: SW416904 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54621 Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Introduce new shared library for image processing fucntionsRichard J. Knight2018-03-024-28/+19
| | | | | | | | | | | | | | | | -Moved xip functions from pm lib into libimageprocs.so -Updated DEPLIBS to include new libimageprocs.so for istep libs. Change-Id: I9e1c90643448146f6e8ef953106c0eea521e35f0 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/51754 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> CI-Ready: Thi N. Tran <thi@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Support sending chip info to SBEs on multinodeDean Sanner2018-02-281-56/+8
| | | | | | | | | | | | | | | | | | | | Existing code didn't support collecting the present chips on all nodes (Hostboot instances) and updating all SBEs with a system wide view. For non multi drawer configs it will just update based on HB instance view. For multi drawer configs the other hostboot instances will be queried for their configs, aggregated, and then informed of the system wide view via IPC commnuication. Change-Id: I45c5673df26f940de212cbe2b54525e32c9147ab Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53603 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Dean Sanner <dsanner@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Delayed deconfig any DIMM on a failing voltage domainNick Bofferding2018-02-231-2/+2
| | | | | | | | | | | | | | | | | | If request to service processor to enable a memory voltage domain fails, delayed deconfig any DIMMs tied to that voltage domain, so that in a reconfig loop the system will boot, but without the affected DIMMs, rather than rebooting endlessly. Change-Id: Icc70c9c3203abefa8085229c7783ee858c8372d6 RTC: SW417148 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54358 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Fix bugs in FSP->HBRT message path for SBE errorsChristian Geddes2018-02-191-4/+4
| | | | | | | | | | | | | | | | | | | | Hostboot was expecting the incorrect order of data in messages sent from the FSP -> PHYP -> HBRT where the SBE is requesting that HBRT reset the SBE. This commit corrects the order and renames the struct for the specific role its used in. Also this commit fixes the values for the MESSAGE type sent by the FSP. CQ: SW415675 Change-Id: I08f44486054e7d0113fd7606bb40ced577080d0c Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53883 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Extend PM Reset flow to collect PM FFDC to HOMERAmit Tendolkar2018-02-171-1/+0
| | | | | | | | | | | | | | | | | | | | | | | | | | | - extend the base flow to ensure ffdc gets collected to homer - revise error xmls - misc changes to handle pm recovery flow triggered via Malf Alert Key_Cronus_Test=PM_REGRESS Change-Id: I12148ed227efe4613332ae76ff142c1d82855f20 RTC: 153979 CQ: SW416537 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53522 Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: RANGANATHPRASAD G. BRAHMASAMUDRA <prasadbgr@in.ibm.com> Reviewed-by: Prem Shanker Jha <premjha2@in.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: HWSV CI <hwsv-ci+hostboot@us.ibm.com> Tested-by: PPE CI <ppe-ci+hostboot@us.ibm.com> Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com> Tested-by: Cronus HW CI <cronushw-ci+hostboot@us.ibm.com> Reviewed-by: Gregory S. Still <stillgs@us.ibm.com> Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53533 Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Christian R. Geddes <crgeddes@us.ibm.com>
* PM: Use auto-special wake-up to cover PM complex reset windowGreg Still2018-02-171-73/+73
| | | | | | | | | | | | | | | | | | | | | | | - Removes SGPE Activity checking in Special Wake-up - Added LMCR scom error check - Fixed some bugs in lmcr check CQ: SW412666 CMVC-Prereq: 1045635 Change-Id: I10948635f3f3b26fe4d9d38f79e13c09a290140a Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52690 Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: PPE CI <ppe-ci+hostboot@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: HWSV CI <hwsv-ci+hostboot@us.ibm.com> Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com> Reviewed-by: RANGANATHPRASAD G. BRAHMASAMUDRA <prasadbgr@in.ibm.com> Reviewed-by: Gregory S. Still <stillgs@us.ibm.com> Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com> Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52696 Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Christian R. Geddes <crgeddes@us.ibm.com>
* Enable platSpecialWakeup during IPL time and add supportChristian Geddes2018-02-172-3/+3
| | | | | | | | | | | | | | | | | | Previously we only supported platSpecialWakeup at runtime because we were not worried about needed special wakeup as the cores would not go into stop state during the IPL. However, now PM code is expecting bits to be set by the p9 special wakeup hwp so we need to call it during the IPL. This code makes the handleSpecialWakeup.C/H files compatible with IPL time build environment and enables the call on the IPL time path CQ: SW415949 Change-Id: I94cca8a84946bea464b21cb95cdbbb075f766c3d Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52858 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Christian R. Geddes <crgeddes@us.ibm.com>
* Update TCE TestcasesMike Baiocchi2018-02-161-1/+1
| | | | | | | | | | | | | | | | | This commit updates and enables the TCE testcases used in HB standalone simics configurations. It also does some minor cleanup to address all outstanding TODOs for this story. Change-Id: I6b1ca049633a8c70b53bb35c776403dc86fec86b RTC:168745 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54085 Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Remove all explicit calls to special_wakeup from hostboot codeChristian Geddes2018-02-168-376/+3
| | | | | | | | | | | | | | The only time that special wakeup should be called on the hostboot platform is when it is called by other HWPs. PM_RESET will only enable special wakeup if the SKIP_WAKEUP attribute is set to 0 Change-Id: Ib9939eae857fa5113a876a717f8169e150b78318 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54148 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Add attribute to give platform more control over PM_RESETChristian Geddes2018-02-141-4/+10
| | | | | | | | | | | | | | | | | | | | | | The PM_RESET hwp calls special wakeup enable on all EX targets, then will clear auto-special wakeup bit on the core if special wakeup is done. In some cases hostboot does not want these steps of the PM_RESET. This attribute gives the platform the ability to decide if they want to enable special wakeup and clear autowakeup on the cores during PM_RESET CQ:SW412666 Change-Id: I8f2e40f4b122f3ff6a048fa6931a1e47f89d3e4f Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53953 Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: HWSV CI <hwsv-ci+hostboot@us.ibm.com> Tested-by: PPE CI <ppe-ci+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com> Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com> Reviewed-by: RANGANATHPRASAD G. BRAHMASAMUDRA <prasadbgr@in.ibm.com> Reviewed-by: Gregory S. Still <stillgs@us.ibm.com> Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53976
* Default to full cache usage during early HostbootDean Sanner2018-02-091-1/+4
| | | | | | | | | | | | | | Early hardware had to support a partial cache config which is inefficient. Placing this code behind a config option, defaulting to full cache usage Change-Id: I521a1d9644d754a2657993603e3e2b2aab90112a Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53606 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Dean Sanner <dsanner@us.ibm.com>
* Only access HB_VOLATILE on non-FSP systemsMatt Derksen2018-02-082-47/+56
| | | | | | | | | | | | | | | | | | This section of memory was added for semi-persistance of variables in a non-FSP environment. Since this section only pertains to non-FSP systems, it therefore should not be accessed by FSP systems. Change-Id: I0dc3181781f8ba55720facaeb2b1e5d67c2817c6 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53293 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Find location of HDAT relocation dynamically from PAYLOADMike Baiocchi2018-02-081-11/+22
| | | | | | | | | | | | | | | | | | | This commit looks at the NACA structure in the Primary PAYLOAD lid to determine the final destination of the HDAT structure that the FSP loaded into a temporary memory space using TCEs. Change-Id: I82b94f5fc133e4222d4efdcc7444012d7bcb5166 RTC:168745 Backport:release-fips910 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53564 Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Remove Istep 10.3 From IPL FlowIlya Smirnov2018-02-083-879/+732
| | | | | | | | | | | | | | | | | | | | | | | Istep 10.3 (host_set_voltages) has been moved to Istep 8.12 and needs to be no-oped. Executing host_set_voltages twice causes crashes due to secureboot thinking we are trying to skip an istep. Note that validateSecuritySettings that was performed in 10.3 has now been moved to 10.4 (with the required sub-routines). Change-Id: I81284157dedebb3f4ee357ce28b29b1dd6a3fe8a CQ:SW416209 CMVC-Coreq:1044932 Backport: release-fips910 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53443 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Set PAYLOAD_KIND attribute based on fused bits in scom registerChristian Geddes2018-02-071-1/+32
| | | | | | | | | | | | | | | | | | | | | | | | | The scom register 0xF000F, bit 57 tells us whether or not the fuse has been blown on this processor. If it is set, that means that it is up to hostboot to set the PAYLOAD_KIND attribute. We decide this based on if we are in SMT4 or SMT8 mode, which is known during istep 6. If we are in SMT4 and the fuse is blown, we can assume PAYLOAD_KIND is OPAL, if we are in SMT8 and the fuse is blown, we are booting PHYP. In a lab scenario on which a system has blown fuses, and we want to force OPAL boot on a system we are forcing to be SMT8, we would have to apply an attribute override to make ATTR_PAYLOAD_KIND = 0x2 . 0x2 is the enum for SAPHHIRE as the payload kind. Change-Id: Ia15dee4dd67130691440bf7fe76915acfb81a19d RTC: 186965 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52957 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* host_coalesce_host: bup updatesPrachi Gupta2018-02-064-70/+107
| | | | | | | | | | | | | | | | | | | | - move p9_fab_iovalid to fab_iovalid common lib to avoid conflicts with hwp lib - doorbell_send to wake up the cores in istep18 - move block wakeup interrupts set later in the istep 18 flow after we have suspended the mbox and drained the interrupt queue Change-Id: I241240ca1d1787182c5baaf3bdd10283878d5798 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52701 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: SWATHI M. BHATTIPROLU <bhmadhur@in.ibm.com> Reviewed-by: Sakethan R. Kotta <sakkotta@in.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Fixes for multinode istep 21.1Dean Sanner2018-02-061-49/+44
| | | | | | | | | | | | | | | -Reordered start_payload to ensure that common things like disabling special wakeup, closing down SBE windows, core xstop, and clearing PM bars are executed as part of our shutdown path -Due to above, needed to correct shared libs loaded on non master HB instance -Added back in the P8 code to pass the payload base to slave HB Instances on populate attr IPC message Change-Id: I5371b9daf7a4e1aadd1743badcd4219604a38ce7 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53343 Tested-by: William G. Hoffa <wghoffa@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Only enable TCEs on drawer 0 for multinodeDean Sanner2018-02-061-1/+10
| | | | | | | | | | | | Change-Id: I0da35514cf1a408886eead3b91ae7d1e5ab78f5c Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53336 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Enable multi-drawer hdat constructionRichard J. Knight2018-02-061-6/+12
| | | | | | | | | | | | | | | | | | | | | -Enable IPC message to drawers to populate hdat -Update HDAT HB reserved memory pointer allocation to be based on the number of drawers in the system -Modify reserved memory pointer allocator to allow drawer specific range of reserved memory pointers -Duplicate data in hdat will be resolved with a follow on commit. Change-Id: I8093a0aac36fbd3d6642db6a1595caa020fd6e78 RTC:186290 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52655 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Set Memory Enabled Bit for all Procs with Valid MemoryBill Hoffa2018-02-061-10/+39
| | | | | | | | | | | | | | - This is only done in Simulation Change-Id: I011ecc6ceb05613b29d8e8e38944b342622b58c0 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53310 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Dean Sanner <dsanner@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Handle INTRP SHUT_DOWN message in MBOX IPC msg_hdlrBill Hoffa2018-02-061-4/+4
| | | | | | | | | | | | | | | | | - Messages sent to MBOX during INTRP shutdown causing IPC Invalid Message Data Errorlogs - Improve Inadvertent IPC Message Handling FFDC Change-Id: Idccad59664e7c95bf8a8618646a13b28c71b4ac7 CQ: SW415386 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52981 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Do Not Unload libruntime.so on MPIPLsMike Baiocchi2018-02-031-14/+1
| | | | | | | | | | | | | | | | | When Hostboot processes MPIPL information on istep 14.8 host_mpipl_service, it needs to preserve that information until it can write it back into the Payload structure after PHYP's HDAT and PAYLOAD are reloaded later in the IPL (istep 20 and 21). Change-Id: I8d629dd268d61c9a4c417c4acc1d6f719f157cae Backport: release-fips910 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53282 Reviewed-by: Stephen M. Cprek <smcprek@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com>
* HB supports - Use ADU chipops to switch fabric configurationThi Tran2018-02-036-18/+23
| | | | | | | | | | | | | Change-Id: I090cdac654d9c6efbe30748713687c6e36ff914d RTC:177597 CQ:SW413432 Backport: release-fips910 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52878 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
OpenPOWER on IntegriCloud