Commit message (Collapse)AuthorAgeFilesLines
* Use proper top-level include for fapi2 targetDan Crowell2019-02-151-2/+2
| | | | | | | | | | | | | | | | | | There is a specific order of #include for fapi2 header files. The generic name (target.H) is the only one that should be used by application code. That header will include the fapi2-specific header (fapi2_target.H) and the plat-specific (plat_target.H) in the proper order. Change-Id: I7e7c3429bfccbc7e1e675a8716fc127695cad15a Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/71539 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Reviewed-by: Brian J. Stegmiller <bjs@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Use ATTR_MAX_COMPUTE_NODES_PER_SYSTEM instead of hardcodingMatt Derksen2018-08-181-9/+3
| | | | | | | | | | | | | | | | | hwsvd crash observed during handling hbrt message to get tod topology data because allocated size was based on a hardcoded value for max_compute_nodes_per_system Change-Id: I587dac32fab9dd67fe96e213c5ef72626e4e2ea1 CQ:SW434860 CMVC-Coreq: 1059506 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/64459 Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Handles FSP reset-reload in HBRT messagesRoland Veloz2017-12-212-290/+179
| | | | | | | | | | | | | | | | | For every instance where a firmware_request is made, it is possible to get an error if the FSP is doing a reset/reload. Now, if an error returned from the firmware_request call indicates that the FSP is doing a reset/reload, the firmware_request call will be made again. Also refactored the code. Consolidated the calls to firmware_request to another file to facilitate the adding/updating of messages. Change-Id: I5be440927ab255c55b40a0a0ed26f786d31a9317 RTC:182606 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/50505 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Adding support for TOD RAS on FSP systemsRoland Veloz2017-12-2022-0/+8391
Moved the TOD files from directory /hostboot/src/usr/isteps/istep18 into a new TOD directory - /hostboot/src/usr/isteps/tod. Created a tod library from the files within the new TOD directory. Added a runtime directory underneath the tod directory. Created the rt_todintf.C file which contains the two newly added interfaces - readTodProcDataFromFile and resetBackupTopology. Change-Id: I68c9edcd8f59adf9a2cf1f1f3fff07fea2d94e99 RTC:171490 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/48188 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>