summaryrefslogtreecommitdiffstats
path: root/src/include
Commit message (Collapse)AuthorAgeFilesLines
* Add some MAGIC instructions to aid Simics optimizationDan Crowell2018-05-301-8/+25
| | | | | | | | | | | | | | | | 8001 - Tell Simics we are waiting on the FSP 8006 - Tell Simics we shutdown 8020 - Tell Simics which istep we're running CQ: SW423959 Change-Id: Icea13d2ed7ff73de04400c46b9b1855e94db7c84 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58104 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Hieu C. Nguyen <hieu.nguyen@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Add test case for getChildTargetsForCDGAndrew Geissler2018-05-292-1/+24
| | | | | | | | | | | | | | | | Some changes are coming to the getChildTargetsForCDG interface in regards to how it returns DIMM information. Get a unit test in place for this function so the future changes can be verified. Change-Id: I731841598f35a169c6dfbbdd873c07dc37d27273 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59072 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Increase default watchdog timeout to 10 minutesDan Crowell2018-05-291-2/+2
| | | | | | | | | | | | | | | | | | | We have discovered some error cases within the memory diagnostics step where a single hardware operation can take up to 6 minutes to complete. The code sends a watchdog ping before issuing any command, but the current timeout (2 minutes) is insufficient to handle these long commands. Resolves boston-openpower/#1240 Change-Id: I4e27a45c927c014b5fcc28d4510c5996a7009953 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59254 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Set Master Proc Attrs during MPIPL FSP Fail-Over ScenarioBill Hoffa2018-05-241-0/+18
| | | | | | | | | | | | | | | | | | | | - Need to account for a Service Processor Fail-Over scenario where the 'master' processor could change. Because of this, FW must re-evaluate which target pointer is the current master and update attributes accordingly. Change-Id: I83ada72389f05cc2a80d4c6a34db7d9ab3c2b3ce CQ: SW429022 RTC: 182718 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59221 Reviewed-by: Richard J. Knight <rjknight@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Clear Block Spec Deconfig Attribute when Gard is removedMarty Gloff2018-05-241-0/+12
| | | | | | | | | | | | | | | | | | | In the Resource Recovery redesign, the Block Spec Deconfig attribute gets set when a check for minimal hardware fails to find enough hardware, and it gets cleared when there is a hardware change. Now, the Block Spec Deconfig attribute will also be cleared when a target that had gard applied no longer has any gard records. Change-Id: I8f93ca4821b1360638a94855c0aadb3dda365046 CQ: SW429890 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59325 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Brian E. Bakke <bbakke@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Thi N. Tran <thi@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Improve FFDC for new Node Comm Device DriverMike Baiocchi2018-05-241-0/+1
| | | | | | | | | | | | | | | | | This commit adds a new custom Node Comm Device Driver error log user details section and its parser code. It also adds a function to add the target and important HW registers to an error log. Change-Id: I11893af06b7a097b43106117d648e9a431c4f3ea RTC:191008 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59079 Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Establish Base Support For Sending Mailbox Messages Across XBUS/ABUSMike Baiocchi2018-05-244-1/+115
| | | | | | | | | | | | | | | | | | | | This commit establishes base support for Secure Node Communications. It creates a new device driver to operate the XBUS and ABUS Link Mailboxes and adds base support for using these device drivers to send and receive messages. It also adds a test to perform a 2-chip XBUS Link Mailbox operation. Change-Id: I19510888c0922e5bb857cffc9426399e79e113ba RTC:191008 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58376 Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Support TPM PCR PoisoningJaymes Wilks2018-05-231-2/+25
| | | | | | | | | | | | | | | | | | | To support Fleetwood secure inter-node communication, we need to “poison” the PCRs of all still functional non-master node TPMs just prior to transferring control to PHyp, and report that poisoned state to HDAT. Change-Id: Ic104ef2e44fc98895b9b435fdf8ba4c5e4972818 RTC:191001 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58244 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Add SMP_CABLE to PartCallout listDan Crowell2018-05-221-0/+1
| | | | | | | | | | | | | | | | | | | | The SMP_CABLE part callout will be used to indicate to the FSP that a SMP cable is at fault. The FSP code will do further analysis, possibly adding more FFDC to the error log or triggering recovery code. Change-Id: Ib7463e5e21c1a9aa75e6a6121e31d742293ef928 RTC: 180336 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59132 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com> Reviewed-by: Srikantha S. Meesala <srikantha@in.ibm.com> Disable-CI: Srikantha S. Meesala <srikantha@in.ibm.com> Reviewed-by: Benjamin J. Weisenbeck <bweisenb@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Add fix for HDAT Fail in Hostboot istep 21: BC8A1A20Richard J. Knight2018-05-221-3/+3
| | | | | | | | | | | | | | | | | | | -On a multi node Fleetwood system with node0 deconfigured the index into the hostboot reserved memory array for the master node exceeds the limit check due to an invalid calculation when nodes other than 0 become the master. The calculation was using the node id instead of the effective instance id. Change-Id: I55d991eda04452aa242fcccad07fede05d29eccb CQ:SW425720 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58113 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* FFDC enhancements for core activate failsDan Crowell2018-05-191-0/+3
| | | | | | | | | | | | | | Adding some more traces to the error log we grab for core activation failures. Change-Id: I30c6985060fcffcb3382b775a52e59c08d2b51b7 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57907 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Get SN from BMC and update into PVPD EEPROMMeng Li2018-05-192-2/+20
| | | | | | | | | | | | Resolves #135 Change-Id: I46b5c2208ed28822c6001a955f4056d976e79339 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58010 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Add option to masterProcChipTargetHandle() to return functional chipMike Baiocchi2018-05-181-2/+15
| | | | | | | | | | | | | | | | | | | | | This commit adds an option to the two masterProcChipTargetHandle() functions to only look for and return a functional master proc chip as necessary with the issue in Defect SW424528. The default behavior of these functions - where the functionality is not checked - remains the same. Once use of these functions has also been updated to use this new option. Change-Id: I37049d2cb9299a9404b57d85031a364bdb257c82 CQ:SW424528 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58920 Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Verify frequency attributes across nodes to match with that of master nodeSwathi Madhuri Bhattiprolu2018-05-164-0/+17
| | | | | | | | | | | | | | | | | | | | | -Existing code ensures consistency of frequency data across all modules in istep6.12. -In a multi-drawer config this data needs to be consistent across all drawers. -Master drawer sends the frequency data to all the other via IPC mechanism. -This data is compared and error is returned if there is a mismatch. Change-Id: Ia1daf1f0eeb90fbafb68417b979488b040efe535 RTC:158036 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57542 Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Improve resource recovery path to handle memory plugging rulesMarty Gloff2018-05-151-0/+10
| | | | | | | | | | | | | | | | | | | | | Resource recovery is a RAS feature wherein we do not apply certain gard records if those records would result in a boot fail due to a lack of hardware. Change the logic from applying speculative deconfiguration one by one to applying all predictive gard records and then removing those records if minimal hardware is not available. Also add BLOCK_SPEC_DECONFIG attribute to flag when speculative deconfiguration is not allowed. This flag is set if minimum hardware is not available and is cleared after a hardware change. Change-Id: Ia065de3a44ab29fbf33ad4ce98bc42ea5144463f RTC: 191414 CQ: SW424137 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58041 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Double frequency of coalescing memory fragmentationThi Tran2018-05-141-2/+2
| | | | | | | | | | | Change-Id: I146289bb2f36519fee5e1fb1dfc07aedf71a1a34 CQ:SW428001 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58704 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Force hb dump on VFS crashesDan Crowell2018-05-111-2/+8
| | | | | | | | | | | | | | | | Added flag to force a HB dump for most VFS crashes. Also added a few constants in the ErrlEntry constructor to make the bool args more obvious. Change-Id: I4f90ee694cece10f567df787f851dca78a895ad7 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57272 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Secure Boot: Inform FSP of key transition progressNick Bofferding2018-05-101-2/+21
| | | | | | | | | | | | | | | | | | | | | | | The existing key transition flow updates all SBE SEEPROMs within the system in the same boot, thereby quiescing all SBEs. This compromises the ability of FSP to detect a key transition TI at the end of the update process because the SBE is not alive to service FSP's incoming SBE FIFO request to read the memory holding the attention information. This change adds new support to log the key transition progress in a node target attribute introduced in an earlier commit and send that status to FSP via a new mailbox message. Change-Id: I828184ae8be89ac87137d7510a3c375cef2e05d7 CQ: SW418697 CMVC-Prereq: 1053806 CMVC-Prereq: 1053552 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56677 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Add additional comparison function objects into functional headerAndre Marin2018-05-101-30/+108
| | | | | | | | | | Change-Id: I6314ec8582e1d9cc284adf877e115433e95a168e Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58217 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* New API to Retrieve Random Number from the TPMJaymes Wilks2018-05-102-2/+33
| | | | | | | | | | | | | | | | | A new programming interface allows us to obtain random numbers from the TPM more easily (i.e. in a more high-level way). Change-Id: Ibd3d3b320411bea146d6eab4d1a59ca760bc726c RTC:191000 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57802 Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Get Final HDAT Size from PAYLOAD's SPIRA sectionMike Baiocchi2018-05-082-1/+5
| | | | | | | | | | | | | | | | | This commit retrieves the amount of space the PAYLOAD has reserved for the HDAT content in its SPIRA section. It then uses this size when copying the HDAT from the temporary location (where the FSP put it with DMAs-via-TCEs) to its final location. Change-Id: I430a78a1655db85f448b3f5c30e6a83f5be4b1f6 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58261 Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Secure Boot: Implement Centaur SCOM cacheNick Bofferding2018-05-082-1/+406
| | | | | | | | | | | | | | | | | | | This change implements a Centaur SCOM cache for sensitive SCOM registers. The cache is initialized and enabled before the first Centaur SCOM, and disabled just prior to locking down the Centaur configuration. Once the Centaur has been locked down, the real register values are compared to the cache entries, and the Centaur is deconfigured (not garded) on any mismatch in assumptions. RTC: 187288 Change-Id: I7b13bfd7eb6b427aba115d6944958bf55e171008 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57532 Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* RTC189294 - Centaur Channel Checkstop (Runtime)Rick Ward2018-05-082-0/+43
| | | | | | | | | | | | | | | | | | | I think this is all that's required to define the SCOM interface to FSP. I used a single structure for request/response because I want to use the generic FSP messaging code, and it assumes that the request and response structs are the same (at least in size). Change-Id: I45d3678db1e265cc1ba5108ea6ffbbe9a15bc307 RTC:189294 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57807 Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Alpana Kumari <alpankum@in.ibm.com> Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Implement Interrupt Resource Provider Init for MPIPL Multi-Node SystemsBill Hoffa2018-05-071-3/+4
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | - In MPIPL the HW interrupt config could be such that interrupts will cross node boundaries. HB handles interrupts independently on each node - so initialize INTRP in a way to handle this transition. - Modify the MPIPL flow with the following changes: a) Set the Interrupt LSI State Machine to disabled b) Enable LSI Mode via the Interrupt Control Register c) Force all nodes to sync after steps a + b - Enable INTRP Multi-Node MPIPL Sync Code developed in P8 - Each node will now initialize its own internode_info data area during an initial IPL - Coalescing of the Host will modify this data to define all the nodes in the system - During the MPIPL each node can view each others area to determine when all nodes have reached the common sync point - Remove Legacy P8 MPIPL INTRP Code that is not used Change-Id: Idb742eafc7389f328ea7f506c4c4541c989e52b6 RTC: 182712 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57993 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Richard J. Knight <rjknight@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Add error log for sbe poweron fails and clean up errlog commitsChristian Geddes2018-05-071-0/+1
| | | | | | | | | | | | | | | | | | | | | | This commit introduces a new error log that will get displayed when a slave SBE fails to reach runtime after the intial start_cbs. Before adding this there was no notification letting the user know that Hostboot failed to boot the slave sbe and that it gave control to the FSP so hwsv can figure out what to do next. In addition to this new error log this commit also updates other errlCommit func calls in the sbe_retry_handler to ensure we are using SBEIO as the component id for these error logs. Change-Id: I73854f753a6186958d55909e8e37a605c1ad57c9 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58049 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: Brian E. Bakke <bbakke@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* wrap test: Use MNFG_FLAGS instead of compile time flagPrachi Gupta2018-05-071-0/+18
| | | | | | | | | | | | Change-Id: I347075dd2424ee8b96805456b3d7d9962f428b64 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58347 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Continuing support, in IStep 09, to facilitate the testing of SMP wrapRoland Veloz2018-05-071-14/+15
| | | | | | | | | | | | | | | Continuing the support, in IStep 09 to make the call to p9_io_obus_linktrain and p9_io_obus_post_trainadv. Change-Id: I3d070bfc6c55224b77b6342362d5d008d0f0a61b RTC:190096 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56886 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> Disable-CI: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Added support, in Istep 08, to facilitate the testing of SMP wrapRoland Veloz2018-05-072-0/+2
| | | | | | | | | | | | | | | | | | Adding support, in Istep 08 to make HWP calls for many various components. In the various istep 8 call_proc_* and istep 10 call_proc*, I was able to consolidate the HWP call into a single single function. The consolidated code for these calls exists in the file nest/nestHwpHelperFuncs. Also added a function to capture errors in file isteps/istepHelperFuncs. Change-Id: I64f73d64950a52d2923f1c3fe280c55dffd1d742 RTC:190096 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56518 Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Rediscover I2C Targets after Host I2C ResetMike Baiocchi2018-05-071-0/+2
| | | | | | | | | | | | | | | | | | | | | | | It's possible that some targets that use I2C to detect if they are present might not be present after a system re-IPLs and performs a FSI I2C Reset. Therefore, later in the IPL, after a Host I2C Reset sequence an attempt to rediscover any of these targets is made. If any new targets are found, the system will re-IPL. Currently only supporting looking for DIMMs now on OpenPower systems with securemode enabled. Change-Id: I010135231f2f74869529a3dbc3344413b6d19dc9 RTC:178973 Backport:release-op920 CQ:SW427365 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57744 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Primary TPM Required PolicyIlya Smirnov2018-05-031-3/+4
| | | | | | | | | | | | | | | | | | Change the "TPM Required" policy to "Primary TPM Required," wherein only the presence and functionality of the primary TPM (attached to the acting master proc) will be considered when evaluating the TPM required condition. The presence and functionality of the backup TPM will not play a role in this policy. Change-Id: Id968123d0fc399c531da7429fdb8efabfa66c53c Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57843 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Secure Boot: Basic Support For Redundant TPMIlya Smirnov2018-05-022-22/+58
| | | | | | | | | | | | | | | | | | | This change implements the detection and initialization of the backup TPM in istep 10.14. The backup TPM is presence-detected and initialized; the logs of the primary TPM are extended into the secondary TPM in istep 10.14. After the initialization of the secondary TPM, all events are extended into both TPMs. A test was created to test whether the backup TPM is initialized correctly. Change-Id: I305500c9f680115e684ab153fc882b8d5364b0d4 RTC: 134912 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57374 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Log an error when FAPI Attribute Overrides are attemptedBrian Bakke2018-05-021-0/+1
| | | | | | | | | | | | | | | | | | | | | Attribute Overrides from FAPI tank are ignored as the Target Type is defaulted in the call tree and thus Attributes for FAPI Targets are never extracted. Add a error log if FAPI Attributes are ingested so there is an indication that these are not supported rather than throwing them silently on the floor. Change-Id: I595e07b03df4d093d7f91b0a8513a8d94c9844dc RTC:177224 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57683 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Brian E. Bakke <bbakke@us.ibm.com> Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Enable super-long watchdog timer when console traces are enabledDan Crowell2018-05-021-9/+5
| | | | | | | | | | | | | | | | | | | | | | | | | | When console traces are enabled, the boot takes significantly longer than usual. Our standard watchdog timeout of 2 minutes is not sufficient. Made the following changes: - Tied the enablement of the long timeout to the CONFIG flags for console traces - Increased the timeout to 1 hour (from 40 minutes) since this is lab only and false positives are the worst... - Added a couple clarifying traces to make future watchdog debug simpler Change-Id: I92bb0b07cb77a13cb390450999b285f2ad74168d CQ: SW425407 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57580 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: Richard J. Knight <rjknight@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* wrap_test: OBUS deconfigurationPrachi Gupta2018-04-272-0/+4
| | | | | | | | | | | | | | | | | | Due to fabric limitations, we can only have 2 OBUSes enabled at a time. This commit deconfigures the OBUSes that do not belong the set of links to enable in this boot based on attributes. Change-Id: I15f5e9f3ea186367b9c4d55f4dc2e9b32b251f6d Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57836 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Elizabeth K. Liner <eliner@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* dump: Copy data type field from MDST table to MDRT tableVasant Hegde2018-04-211-2/+5
| | | | | | | | | | | | | | | | | In case of OPAL system MDST and MDDT contains entries from multiple sources (OPAL, kernel, etc,). Post MPIPL OPAL needs a way to differentiate between them. Hence copy type field from MDST table to MDRT table. Change-Id: I3f196cdc58e7376d7743188d0a6b76c99799b5ad Signed-off-by: Vasant Hegde <hegdevasant@linux.vnet.ibm.com> Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55187 CI-Ready: RAJA DAS <rajadas2@in.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> CI-Ready: Sachin Gupta <sgupta2m@in.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Add support to find relocated payload base addressVasant Hegde2018-04-193-3/+19
| | | | | | | | | | | | | | | | | | | | | | | OPAL relocates itself after boot. During MPIPL, hostboot needs to access relocated SPIRAH. Hence lets add support to get relocated payload base address. OPAL will use SBE stash chip-op to send relocated address to SBE. During early IPL SBE sends stashed data to hostboot. And hostboot will use that information to find relocated payload (OPAL) base. SBE stash chip op: key = 0x03 val = <relocated payload base address> Change-Id: I1089bd38f32b01b877d1580ba76313fc250e5c08 Signed-off-by: Vasant Hegde <hegdevasant@linux.vnet.ibm.com> Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55190 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Create new HWP Invoker macro that returns the RCDan Crowell2018-04-191-1/+27
| | | | | | | | | | | | | | | | Allow the RC of a HWP to be returned along with the associated error log. This allows logic to be based on the specific RC if needed. Change-Id: I90a78ace2cc4263265940764dffd0691dd56e2f5 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57302 Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Caleb N. Palmer <cnpalmer@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Adding path to use alt-memory when proc0 does not have memoryElizabeth Liner2018-04-191-1/+2
| | | | | | | | | | | | | | | | | | | | When proc0 doesn't have memory, and we are on a phyp system, we don't need to swap our master proc and we can instead just swap memory. This commit adds in the functionality to look for working memory, and send both the group and chip ID down to HWSV. Change-Id: I664d5bfcd308a4ba2ee71e3e708533c6ec9a0a71 RTC:176434 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54403 CI-Ready: Elizabeth K. Liner <eliner@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> CI-Ready: Sachin Gupta <sgupta2m@in.ibm.com> Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Check for pending OCC messages on HBRT start in OpenPOWERBrian Bakke2018-04-171-0/+6
| | | | | | | | | | | | | | | | | | | The OCC will set an interrupt for the Host to look for a pending message/action. If opal-prd is not running at the time that this interrupt happens, HTMGT will never see the message. Therefore we need to have HTMGT explicitly check for anything pending any time HBRT starts up. Change-Id: Iaae075ae6828a9de5a7bd5afe55c541b0076f2d2 RTC: 187912 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57175 Reviewed-by: Christopher J. Cain <cjcain@us.ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Add an option disable fsp to sm sync for some attributes.Dhruvaraj Subhashchandran2018-04-161-0/+73
| | | | | | | | | | | | | | | | A new XML file with list of attributes need not be synced is accepted by the script. The attributes in the list is excluded from the output XML processed to create system model tables. Change-Id: If1d3a02d574988ce5e0fa503bab2fd0e4accdb8d Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56636 CI-Ready: DHRUVARAJ SUBHASH CHANDRAN <dhruvaraj@in.ibm.com> Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Improve linking of PLIDs for sbe_retry_handlerChristian Geddes2018-04-131-11/+32
| | | | | | | | | | | | | | | | | | Previously if a PLID was passed to the ctor of the sbe_retry_handler we would link all errors logs created during the process of recovering the SBE with this PLID. But if no PLID was passed then we would not link the logs. This commit changes it so if no PLID is passed to the ctor then the first log created in the recovery process will become the PLID that all logs after will be set to. Change-Id: I93ef3a48b4cc1d7df3237d7ba3dfefba21d5fb6b Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56885 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Multinode SBE Window SupportJaymes Wilks2018-04-131-1/+3
| | | | | | | | | | | | | | | | | | | Code for SP ATTN, COMM, and SBE FFDC areas has been extended to all chips/nodes. The COMM area base address calculation is now updated to use the lowest addressable location for the master node. Change-Id: Ib02e62958a520c60e4bcc5bd9d4c4257893adbd9 RTC:189038 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56614 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Multinode SBE Window Support - Export OPALJaymes Wilks2018-04-131-0/+2
| | | | | | | | | | | | | | | | Extends SBE window support to open a new window for OPAL trace. Change-Id: Ifee6fe4a8cc1e58ca9ddd00d57c91356ad55cc3d RTC:191010 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57054 CI-Ready: Marshall J. Wilks <mjwilks@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com>
* Log Hostboot state information in all error logsDan Crowell2018-04-133-2/+92
| | | | | | | | | | | | | | | | Add the Istep number and substep number to Hostboot Error Logs to assist in problem debug. These items will be added as a user data record to all Hostboot Error Logs prior to Runtime. Change-Id: Ib5d269f3c1853d6d6856669744630dc130fa7094 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54764 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Add deconfigTargetAtRuntime interfaceRichard J. Knight2018-04-123-2/+62
| | | | | | | | | | | | | | | | | | | | | | | -PRD will call this function in response to a core unit checkstop detected by PHYP. The new function will mark the core as non-functional and call a hardware procdure to update the multicast groups for cores and chiplets. The procedure will also update the OCC core configuration status and the quad core status registers which reflect the number of enable cores/quad in the system at runtime. Change-Id: Ia7fc3f47dc1fee1f84d877d3d56b609d1aee1b17 RTC:188918 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55154 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Richard Ward <rward15@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Mark Read-Only Partitions as SuchIlya Smirnov2018-04-121-0/+1
| | | | | | | | | | | | | | | | | | Partitions marked with readOnly tag in the xml were treated as WRITABLE in the code. This change modifies the permissions to be READ_ONLY and adds unit tests to test the read only functionality. Change-Id: I8c1f23fd7e30edc38ff882c59716ab63a4f310e6 CQ: SW423350 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56771 CI-Ready: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com> Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57066 Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
* Support multiple nodes in HBRT - Remove Single Node ItemsMarty Gloff2018-04-102-7/+9
| | | | | | | | | | | | | | | | | | | There are some items that applied to a single node implementation that can be removed after all dependencies on them have been removed by other tasks. This single node support is being moved/removed. Also a check is being added to the VPD support so the node value does not index beyond the end of the array of reserved memory addresses. Change-Id: I7fea5ac9cdfa9f37caa57905d320633a8039e79d RTC: 186585 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55917 Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Revert "Clear perv scrach register prior to triggering HRESET"Christian R. Geddes2018-04-101-15/+0
| | | | | | | | | | This reverts commit 4f32915aa1240d07bb2671010f95695ba5f306c3. Change-Id: Ie51fd274d018df63aef6f725bf57c7b1f7f59265 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57026 CI-Ready: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Christian R. Geddes <crgeddes@us.ibm.com>
* Clear perv scrach register prior to triggering HRESETChristian Geddes2018-04-101-0/+15
| | | | | | | | | | | | | | | | | | | | | | Before we initiate an HRESET we need to make sure that the perv scratch register that the SBE looks at during boot are all zeros. When these registers are zeros the SBE will ignore them and pull values from its own image. We need to do this because Hostboot will repurpose these registers after the SBE boots the first time so the data in the registers is no longer valid. It is okay for the SBE to pull the values from it's own image because during the IPL hostboot customized the SBE image with the correct values. Change-Id: I8b434d04cde3c384e35a3089a349a1d121b6b1dc RTC: 180242 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56959 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> CI-Ready: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Improve error handling when slave SBE fails to bootChristian Geddes2018-04-101-0/+1
| | | | | | | | | | | | | | | | If we fail to boot the slave SBE we should mark it in the istep errlog to ensure that we fail the istep and perform a reconfig loop. Change-Id: I70e67b5b3e1e35e0ee76eb1f158435ee44a436ef Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56882 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
OpenPOWER on IntegriCloud