+# NVDIMM Secure Erase Verify Flow
+DS8K lpar -> HBRT NVDIMM operation = factory_default + secure_erase_verify_start
+ HBRT executes factory_default and steps 1) and 2)
+DS8K lpar -> HBRT NVDIMM operation = secure_erase_verify_complete
+ HBRT executes step 3)
+ If secure erase verify has not completed, return status with verify_complete bit = 0
+ DS8K lpar is responsible for monitoring elapsed time (2/4 hours) and restart process (step 6)
+ If secure erase verify has completed
+ HBRT executes steps 4) and 5), generating error logs for any non-zero register values
+ Return status with verify_complete bit = 1
+
+## Procedure Flow for NVDIMM Secure Erase Verify
+ *Note: Secure Erase Verify should only be run after a Factory Default operation.
+ Secure Erase Verify is intended to verify whether all NAND blocks have been erased.
+ *Note: Full breakout of all Page 5 Secure Erase Verify registers can be found in
+ SMART document "JEDEC NVDIMM Vendor Page 2 Extensions".
+ 1) Set Page 5 Register 0x1B to value "0x00"
+ // this clears the status register
+ 2) Set Page 5 Register 0x1A to value "0xC0"
+ // this kicks off the erase verify operation
+ 3) Wait for Page 5 Register 0x1A Bit 7 to be reset to value "0"
+ // i.e., the overall register value should be "0x40";
+ this means that erase verify has completed
+ a. If Page 5 Register 0x1A Bit 7 has not reset to value "0"
+ after 2 hours (16GB NVDIMM) or after 4 hours (32GB NVDIMM),
+ report a timeout error and skip to step (6)
+ 4) Read Page 5 Register 0x1B; value should be "0x00"
+ // this is the erase verify status register
+ a. If Page 5 Register 0x1B value is not "0x00",
+ report any/all errors as outlined in the table at the end of this document,
+ then skip to step (6)
+ 5) Read Page 5 Registers 0x1D (MSB) and 0x1C (LSB);
+ combined the two registers should have a value of "0x0000"
+ // this is the number of chunks failing Secure Erase Verify
+ a. If the combined value of the two registers is not "0x0000",
+ report a threshold exceeded error along with the combined value of the two registers,
+ then skip to step (6)
+ 6) If any errors have been reported in steps (3), (4), or (5),
+ retry the secure erase verify operation starting again from step (1)
+ a. If the secure erase verify operation fails even after retrying,
+ report that secure erase verify operation has failed
+ 7) If no errors have been reported, report that secure erase verify operation
+ has been completed successfully
+ *Addendum: Breakout of Page 5 Register 0x1B Erase Verify Status bit values referenced in step (4) above.
+ All these bits should return as "0". Any bits returning as "1" should be reported with the error name below.
+ Bits 7:6 - Reserved
+ Bit 5 - BAD BLOCK
+ Bit 4 - OTHER
+ Bit 3 - ENCRYPTION LOCKED
+ Bit 2 - INVALID PARAMETER
+ Bit 1 - INTERRUPTED
+ Bit 0 - NAND ERROR
+