Verify frequency attributes across nodes to match with that of master node
-Existing code ensures consistency of frequency data
across all modules in istep6.12.
-In a multi-drawer config this data needs to be consistent
across all drawers.
-Master drawer sends the frequency data to all the other
via IPC mechanism.
-This data is compared and error is returned if there is a mismatch.
Change-Id: Ia1daf1f0eeb90fbafb68417b979488b040efe535
RTC:158036
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57542
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Roland Veloz <rveloz@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Diffstat (limited to 'src/include')
-rw-r--r-- | src/include/usr/hwas/common/hwasCallout.H | 7 | ||||
-rw-r--r-- | src/include/usr/isteps/istep_reasoncodes.H | 8 | ||||
-rw-r--r-- | src/include/usr/mbox/ipc_msg_types.H | 1 | ||||
-rw-r--r-- | src/include/usr/mbox/mbox_queues.H | 1 |
4 files changed, 17 insertions, 0 deletions
diff --git a/src/include/usr/hwas/common/hwasCallout.H b/src/include/usr/hwas/common/hwasCallout.H index c5fbf2f21..a74330aaf 100644 --- a/src/include/usr/hwas/common/hwasCallout.H +++ b/src/include/usr/hwas/common/hwasCallout.H @@ -61,6 +61,13 @@ typedef enum { GARD_Void = 0xFF } GARD_ErrorType; +// Used in EPUB_PRC_INVALID_PART +// userdata 3 of the SRC +enum ErrorCategory { + ERR_CATEGORY_INVALID_SERIAL = 0x01, + ERR_CATEGORY_INVALID_PART = 0x02, +}; + // from src/epub/fsp/epub_service_codes.H v1.24.24.4 // - Any additions should be added to FipS code first diff --git a/src/include/usr/isteps/istep_reasoncodes.H b/src/include/usr/isteps/istep_reasoncodes.H index 1595210e3..aa63ce0d8 100644 --- a/src/include/usr/isteps/istep_reasoncodes.H +++ b/src/include/usr/isteps/istep_reasoncodes.H @@ -61,6 +61,7 @@ namespace ISTEP MOD_OCC_XSTOP_HANDLER = 0x1E, MOD_VERIFY_AND_MOVE_PAYLOAD = 0x1F, MOD_REDISCOVER_I2C_TARGETS = 0x20, + MOD_FREQ_ATTR_DATA = 0x21, }; /** @@ -118,6 +119,13 @@ namespace ISTEP RC_FAILED_TO_BOOT_SBE = ISTEP_COMP_ID | 0x38, RC_REDISCOVERED_TARGETS = ISTEP_COMP_ID | 0x39, RC_HDAT_SIZE_CHECK_FAILED = ISTEP_COMP_ID | 0x3A, + RC_FREQ_ATTR_TIMER_EXPIRED = ISTEP_COMP_ID | 0x40, + RC_FREQ_ATTR_TIMER_THREAD_FAIL = ISTEP_COMP_ID | 0x41, + RC_FLOOR_FREQ_MISMATCH = ISTEP_COMP_ID | 0x42, + RC_CEIL_FREQ_MISMATCH = ISTEP_COMP_ID | 0x43, + RC_TURBO_FREQ_MISMATCH = ISTEP_COMP_ID | 0x44, + RC_ULTRA_TURBO_FREQ_MISMATCH = ISTEP_COMP_ID | 0x45, + RC_NEST_FREQ_MISMATCH = ISTEP_COMP_ID | 0x46, }; }; diff --git a/src/include/usr/mbox/ipc_msg_types.H b/src/include/usr/mbox/ipc_msg_types.H index 6a907ed8d..ee0896348 100644 --- a/src/include/usr/mbox/ipc_msg_types.H +++ b/src/include/usr/mbox/ipc_msg_types.H @@ -41,6 +41,7 @@ namespace IPC IPC_SET_SBE_CHIPINFO, IPC_CLOSE_TCES, IPC_POPULATE_TPM_INFO_BY_NODE, + IPC_FREQ_ATTR_DATA, // frequency attribute data from master to other drawers }; }; // namespace IPC diff --git a/src/include/usr/mbox/mbox_queues.H b/src/include/usr/mbox/mbox_queues.H index 882aad2b4..3b3b6ba10 100644 --- a/src/include/usr/mbox/mbox_queues.H +++ b/src/include/usr/mbox/mbox_queues.H @@ -56,6 +56,7 @@ namespace MBOX HB_SBE_SYSCONFIG_MSGQ = 12, //For SBE System Config response HB_CLOSE_TCES_MSGQ = 13, // close/disable TCEs HB_POP_TPM_INFO_MSGQ = 14, // response to populate TPM info by node + HB_FREQ_ATTR_DATA_MSGQ = 15, // freq attributes data from master to all other drawers // Add HB mbox msg queue ids (services) before this line HB_LAST_VALID_MSGQ, // end of valid HB mbox msgQ ids |