<feed xmlns='http://www.w3.org/2005/Atom'>
<title>talos-hostboot/src/usr/isteps/pm/runtime, branch master</title>
<subtitle>Talos™ II hostboot sources</subtitle>
<id>https://git.raptorcs.com/git/talos-hostboot/atom?h=master</id>
<link rel='self' href='https://git.raptorcs.com/git/talos-hostboot/atom?h=master'/>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/'/>
<updated>2018-02-19T14:43:09+00:00</updated>
<entry>
<title>Fix bugs in FSP-&gt;HBRT message path for SBE errors</title>
<updated>2018-02-19T14:43:09+00:00</updated>
<author>
<name>Christian Geddes</name>
<email>crgeddes@us.ibm.com</email>
</author>
<published>2018-02-12T20:59:05+00:00</published>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/commit/?id=8d28433bcc3c927ee76cdc4231099660545b1bfa'/>
<id>urn:sha1:8d28433bcc3c927ee76cdc4231099660545b1bfa</id>
<content type='text'>
Hostboot was expecting the incorrect order of data in messages sent
from the FSP -&gt; PHYP -&gt; HBRT where the SBE is requesting that HBRT
reset the SBE. This commit corrects the order and renames the struct
for the specific role its used in. Also this commit fixes the values
for the MESSAGE type sent by the FSP.

CQ: SW415675
Change-Id: I08f44486054e7d0113fd7606bb40ced577080d0c
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53883
Tested-by: Jenkins Server &lt;pfd-jenkins+hostboot@us.ibm.com&gt;
Tested-by: FSP CI Jenkins &lt;fsp-CI-jenkins+hostboot@us.ibm.com&gt;
Tested-by: Jenkins OP Build CI &lt;op-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Roland Veloz &lt;rveloz@us.ibm.com&gt;
Tested-by: Jenkins OP HW &lt;op-hw-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Matt Derksen &lt;mderkse1@us.ibm.com&gt;
Reviewed-by: ILYA SMIRNOV &lt;ismirno@us.ibm.com&gt;
Reviewed-by: Daniel M. Crowell &lt;dcrowell@us.ibm.com&gt;
</content>
</entry>
<entry>
<title>PM: Use auto-special wake-up to cover PM complex reset window</title>
<updated>2018-02-17T21:26:51+00:00</updated>
<author>
<name>Greg Still</name>
<email>stillgs@us.ibm.com</email>
</author>
<published>2018-01-26T03:15:47+00:00</published>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/commit/?id=54a8d9a839e8127991e5b582045d1a44ea526007'/>
<id>urn:sha1:54a8d9a839e8127991e5b582045d1a44ea526007</id>
<content type='text'>
- Removes SGPE Activity checking in Special Wake-up
- Added LMCR scom error check
- Fixed some bugs in lmcr check

CQ: SW412666
CMVC-Prereq: 1045635
Change-Id: I10948635f3f3b26fe4d9d38f79e13c09a290140a
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52690
Tested-by: FSP CI Jenkins &lt;fsp-CI-jenkins+hostboot@us.ibm.com&gt;
Tested-by: PPE CI &lt;ppe-ci+hostboot@us.ibm.com&gt;
Tested-by: Jenkins Server &lt;pfd-jenkins+hostboot@us.ibm.com&gt;
Tested-by: HWSV CI &lt;hwsv-ci+hostboot@us.ibm.com&gt;
Tested-by: Hostboot CI &lt;hostboot-ci+hostboot@us.ibm.com&gt;
Reviewed-by: RANGANATHPRASAD G. BRAHMASAMUDRA &lt;prasadbgr@in.ibm.com&gt;
Reviewed-by: Gregory S. Still &lt;stillgs@us.ibm.com&gt;
Reviewed-by: Jennifer A. Stofer &lt;stofer@us.ibm.com&gt;
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52696
Tested-by: Jenkins OP Build CI &lt;op-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Christian R. Geddes &lt;crgeddes@us.ibm.com&gt;
Tested-by: Christian R. Geddes &lt;crgeddes@us.ibm.com&gt;
</content>
</entry>
<entry>
<title>Enable platSpecialWakeup during IPL time and add support</title>
<updated>2018-02-17T21:26:17+00:00</updated>
<author>
<name>Christian Geddes</name>
<email>crgeddes@us.ibm.com</email>
</author>
<published>2018-01-29T20:49:19+00:00</published>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/commit/?id=b542fd6392999e7d521c5dff5a2a2add056db984'/>
<id>urn:sha1:b542fd6392999e7d521c5dff5a2a2add056db984</id>
<content type='text'>
Previously we only supported platSpecialWakeup at runtime because
we were not worried about needed special wakeup as the cores would
not go into stop state during the IPL. However, now PM code is expecting
bits to be set by the p9 special wakeup hwp so we need to call it during
the IPL. This code makes the handleSpecialWakeup.C/H files compatible
with IPL time build environment and enables the call on the IPL time path

CQ: SW415949
Change-Id: I94cca8a84946bea464b21cb95cdbbb075f766c3d
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52858
Tested-by: Jenkins Server &lt;pfd-jenkins+hostboot@us.ibm.com&gt;
Tested-by: Jenkins OP Build CI &lt;op-jenkins+hostboot@us.ibm.com&gt;
Tested-by: Jenkins OP HW &lt;op-hw-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Christian R. Geddes &lt;crgeddes@us.ibm.com&gt;
Tested-by: Christian R. Geddes &lt;crgeddes@us.ibm.com&gt;
</content>
</entry>
<entry>
<title>Fixed HBRT issue where virt addr not unmapped at the end of complex calls.</title>
<updated>2018-01-25T14:35:21+00:00</updated>
<author>
<name>Tom Sand</name>
<email>trsand@us.ibm.com</email>
</author>
<published>2018-01-22T17:38:21+00:00</published>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/commit/?id=82769e0a939f902d9bbbb36404ab787990ff237b'/>
<id>urn:sha1:82769e0a939f902d9bbbb36404ab787990ff237b</id>
<content type='text'>
This caused all buffers to be mapped after two sockets and so a three
or four socket system ran out of buffers. Ultimately the PHYP Hype
component took the system down with a B700F103 because it did not
get data for sockets beyond the second one.

Change-Id: I84a001271ff4d7395312435f967bd7935e364f15
CQ: SW414288
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52378
Tested-by: Jenkins Server &lt;pfd-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Martin Gloff &lt;mgloff@us.ibm.com&gt;
Reviewed-by: Daniel M. Crowell &lt;dcrowell@us.ibm.com&gt;
</content>
</entry>
<entry>
<title>Support for any target deconfig at runtime; Utility to create a generic message</title>
<updated>2018-01-17T21:08:40+00:00</updated>
<author>
<name>Roland Veloz</name>
<email>rveloz@us.ibm.com</email>
</author>
<published>2017-12-20T18:08:19+00:00</published>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/commit/?id=6f4abd1ea46f9b8f4fa1d0632276df8ad77d47d4'/>
<id>urn:sha1:6f4abd1ea46f9b8f4fa1d0632276df8ad77d47d4</id>
<content type='text'>
I added code to inform FSP whenever a target has been deconfiged.
I also added a handy utility to facilitate in the construction of
a Generic FSP message.

Change-Id: Iad755d4de1bf200ab00ad3f99451512ba8cdabb4
RTC: 183950
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/51201
Reviewed-by: Martin Gloff &lt;mgloff@us.ibm.com&gt;
Reviewed-by: Christian R. Geddes &lt;crgeddes@us.ibm.com&gt;
Tested-by: Jenkins Server &lt;pfd-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Daniel M. Crowell &lt;dcrowell@us.ibm.com&gt;
</content>
</entry>
<entry>
<title>Handles FSP reset-reload in HBRT messages</title>
<updated>2017-12-21T05:12:25+00:00</updated>
<author>
<name>Roland Veloz</name>
<email>rveloz@us.ibm.com</email>
</author>
<published>2017-12-04T23:37:05+00:00</published>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/commit/?id=44d0f070400aabde3a06eb7b836923577a117cc0'/>
<id>urn:sha1:44d0f070400aabde3a06eb7b836923577a117cc0</id>
<content type='text'>
For every instance where a firmware_request is made, it is possible
to get an error if the FSP is doing a reset/reload.  Now, if an
error returned from the firmware_request call indicates that the
FSP is doing a reset/reload, the firmware_request call will be made
again. Also refactored the code.  Consolidated the calls to
firmware_request to another file to facilitate the adding/updating
of messages.

Change-Id: I5be440927ab255c55b40a0a0ed26f786d31a9317
RTC:182606
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/50505
Tested-by: Jenkins Server &lt;pfd-jenkins+hostboot@us.ibm.com&gt;
Tested-by: Jenkins OP Build CI &lt;op-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Daniel M. Crowell &lt;dcrowell@us.ibm.com&gt;
</content>
</entry>
<entry>
<title>Adding support for TOD RAS on FSP systems</title>
<updated>2017-12-20T22:47:47+00:00</updated>
<author>
<name>Roland Veloz</name>
<email>rveloz@us.ibm.com</email>
</author>
<published>2017-10-10T15:55:09+00:00</published>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/commit/?id=a69cb64611f39c3320e71a025cc612690305926d'/>
<id>urn:sha1:a69cb64611f39c3320e71a025cc612690305926d</id>
<content type='text'>
Moved the TOD files from directory /hostboot/src/usr/isteps/istep18
into a new TOD directory - /hostboot/src/usr/isteps/tod.  Created a tod
library from the files within the new TOD directory.  Added a runtime
directory underneath the tod directory.  Created the rt_todintf.C file
which contains the two newly added interfaces -
readTodProcDataFromFile and resetBackupTopology.

Change-Id: I68c9edcd8f59adf9a2cf1f1f3fff07fea2d94e99
RTC:171490
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/48188
Tested-by: Jenkins Server &lt;pfd-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Christian R. Geddes &lt;crgeddes@us.ibm.com&gt;
Tested-by: Jenkins OP Build CI &lt;op-jenkins+hostboot@us.ibm.com&gt;
Tested-by: Jenkins OP HW &lt;op-hw-jenkins+hostboot@us.ibm.com&gt;
Tested-by: FSP CI Jenkins &lt;fsp-CI-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Daniel M. Crowell &lt;dcrowell@us.ibm.com&gt;
</content>
</entry>
<entry>
<title>Handle SBE Error and Attempt Recovery from FSP</title>
<updated>2017-12-20T22:47:34+00:00</updated>
<author>
<name>Roland Veloz</name>
<email>rveloz@us.ibm.com</email>
</author>
<published>2017-11-10T15:44:18+00:00</published>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/commit/?id=f0db3bed83349756e9182077b02c1c73e473a569'/>
<id>urn:sha1:f0db3bed83349756e9182077b02c1c73e473a569</id>
<content type='text'>
This handles an SBE Error from the FSP and attempts
to recover the SBE.

Change-Id: I18ef0179b0d79df8ea5d51fdda51d8b09391120a
RTC:180609
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/49916
Reviewed-by: Martin Gloff &lt;mgloff@us.ibm.com&gt;
Tested-by: Jenkins Server &lt;pfd-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Christian R. Geddes &lt;crgeddes@us.ibm.com&gt;
Tested-by: Jenkins OP Build CI &lt;op-jenkins+hostboot@us.ibm.com&gt;
Tested-by: Jenkins OP HW &lt;op-hw-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: Daniel M. Crowell &lt;dcrowell@us.ibm.com&gt;
</content>
</entry>
<entry>
<title>Updated the GenericFspMboxMessage_t struct</title>
<updated>2017-12-20T22:47:12+00:00</updated>
<author>
<name>Roland Veloz</name>
<email>rveloz@us.ibm.com</email>
</author>
<published>2017-11-21T21:02:53+00:00</published>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/commit/?id=8e6bd68539af8394a3f96dab15464edc151794bb'/>
<id>urn:sha1:8e6bd68539af8394a3f96dab15464edc151794bb</id>
<content type='text'>
The GenericFspMboxMessage_t struct has been expanded to provide
a lot more data than before. The highlights are that it now
carries the data size, an error only flag, a sequence number
and a magic number to identify the message.  An initialize
method has been provided to set some of these to default
values.  In addition the message types are consolidated into
one enum.  All enums have a prefix of GFMM to avoid name
collisions. The sequence number is an auto incrementing
number so we can keep track if the messages are received out
of order.

Change-Id: Ic0f1c2546ff1ce14f163d1da55646ed089216d19
RTC: 182267
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/49960
Reviewed-by: Daniel M. Crowell &lt;dcrowell@us.ibm.com&gt;
Tested-by: Jenkins Server &lt;pfd-jenkins+hostboot@us.ibm.com&gt;
</content>
</entry>
<entry>
<title>Updated VPD from HBRT on FSP systems</title>
<updated>2017-10-06T18:22:35+00:00</updated>
<author>
<name>Roland Veloz</name>
<email>rveloz@us.ibm.com</email>
</author>
<published>2017-08-23T15:29:57+00:00</published>
<link rel='alternate' type='text/html' href='https://git.raptorcs.com/git/talos-hostboot/commit/?id=2a1cc4f4045ddfb247a7be1a18593a9836db8412'/>
<id>urn:sha1:2a1cc4f4045ddfb247a7be1a18593a9836db8412</id>
<content type='text'>
Created a generic message type that is used as a mailbox message that
is passed from HBRT to FSP.  The new generic message type is used
to make a VPD write call.

Change-Id: I21240d19909f786d525e2a98878000af4aea6e9f
RTC:171488
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/45048
Tested-by: Jenkins Server &lt;pfd-jenkins+hostboot@us.ibm.com&gt;
Tested-by: Jenkins OP Build CI &lt;op-jenkins+hostboot@us.ibm.com&gt;
Tested-by: Jenkins OP HW &lt;op-hw-jenkins+hostboot@us.ibm.com&gt;
Tested-by: FSP CI Jenkins &lt;fsp-CI-jenkins+hostboot@us.ibm.com&gt;
Reviewed-by: William G. Hoffa &lt;wghoffa@us.ibm.com&gt;
Reviewed-by: Daniel M. Crowell &lt;dcrowell@us.ibm.com&gt;
</content>
</entry>
</feed>
