diff options
Diffstat (limited to 'sensorhandler.cpp')
-rw-r--r-- | sensorhandler.cpp | 140 |
1 files changed, 37 insertions, 103 deletions
diff --git a/sensorhandler.cpp b/sensorhandler.cpp index f9294eb..2bd022b 100644 --- a/sensorhandler.cpp +++ b/sensorhandler.cpp @@ -797,105 +797,49 @@ ipmi_ret_t ipmi_sen_reserve_sdr(ipmi_netfn_t netfn, ipmi_cmd_t cmd, return IPMI_CC_OK; } -void setUnitFieldsForObject(sd_bus *bus, - const dbus_interface_t &iface, - const ipmi::sensor::Info *info, +void setUnitFieldsForObject(const ipmi::sensor::Info *info, get_sdr::SensorDataFullRecordBody *body) { - if (info->propertyInterfaces.begin()->first == - "xyz.openbmc_project.Sensor.Value") + namespace server = sdbusplus::xyz::openbmc_project::Sensor::server; + try { - std::string result {}; - if (info->unit.empty()) - { - char *raw_cstr = NULL; - if (0 > sd_bus_get_property_string(bus, iface.bus, iface.path, - iface.interface, "Unit", NULL, - &raw_cstr)) - { - log<level::WARNING>("Unit interface missing.", - entry("BUS=%s", iface.bus), - entry("PATH=%s", iface.path)); - } - else - { - result = raw_cstr; - } - free(raw_cstr); - } - else + auto unit = server::Value::convertUnitFromString(info->unit); + // Unit strings defined in + // phosphor-dbus-interfaces/xyz/openbmc_project/Sensor/Value.interface.yaml + switch (unit) { - result = info->unit; - } - - namespace server = sdbusplus::xyz::openbmc_project::Sensor::server; - try { - auto unit = server::Value::convertUnitFromString(result); - // Unit strings defined in - // phosphor-dbus-interfaces/xyz/openbmc_project/Sensor/Value.interface.yaml - switch (unit) - { - case server::Value::Unit::DegreesC: - body->sensor_units_2_base = get_sdr::SENSOR_UNIT_DEGREES_C; - break; - case server::Value::Unit::RPMS: - body->sensor_units_2_base = get_sdr::SENSOR_UNIT_REVOLUTIONS; // revolutions - get_sdr::body::set_rate_unit(0b100, body); // per minute - break; - case server::Value::Unit::Volts: - body->sensor_units_2_base = get_sdr::SENSOR_UNIT_VOLTS; - break; - case server::Value::Unit::Meters: - body->sensor_units_2_base = get_sdr::SENSOR_UNIT_METERS; - break; - case server::Value::Unit::Amperes: - body->sensor_units_2_base = get_sdr::SENSOR_UNIT_AMPERES; - break; - case server::Value::Unit::Joules: - body->sensor_units_2_base = get_sdr::SENSOR_UNIT_JOULES; - break; - default: - // Cannot be hit. - fprintf(stderr, "Unknown value unit type: = %s\n", result.c_str()); - } - } - catch (sdbusplus::exception::InvalidEnumString e) - { - log<level::WARNING>("Warning: no unit provided for sensor!"); + case server::Value::Unit::DegreesC: + body->sensor_units_2_base = get_sdr::SENSOR_UNIT_DEGREES_C; + break; + case server::Value::Unit::RPMS: + body->sensor_units_2_base = get_sdr::SENSOR_UNIT_REVOLUTIONS; // revolutions + get_sdr::body::set_rate_unit(0b100, body); // per minute + break; + case server::Value::Unit::Volts: + body->sensor_units_2_base = get_sdr::SENSOR_UNIT_VOLTS; + break; + case server::Value::Unit::Meters: + body->sensor_units_2_base = get_sdr::SENSOR_UNIT_METERS; + break; + case server::Value::Unit::Amperes: + body->sensor_units_2_base = get_sdr::SENSOR_UNIT_AMPERES; + break; + case server::Value::Unit::Joules: + body->sensor_units_2_base = get_sdr::SENSOR_UNIT_JOULES; + break; + case server::Value::Unit::Watts: + body->sensor_units_2_base = get_sdr::SENSOR_UNIT_WATTS; + break; + default: + // Cannot be hit. + fprintf(stderr, "Unknown value unit type: = %s\n", + info->unit.c_str()); } } -} - -int64_t getScaleForObject(sd_bus *bus, - const dbus_interface_t& iface, - const ipmi::sensor::Info *info) -{ - int64_t result = 0; - if (info->propertyInterfaces.begin()->first == - "xyz.openbmc_project.Sensor.Value") + catch (sdbusplus::exception::InvalidEnumString e) { - if (info->hasScale) - { - result = info->scale; - } - else - { - if (0 > sd_bus_get_property_trivial(bus, - iface.bus, - iface.path, - iface.interface, - "Scale", - NULL, - 'x', - &result)) { - log<level::WARNING>("Scale interface missing.", - entry("BUS=%s", iface.bus), - entry("PATH=%s", iface.path)); - } - } + log<level::WARNING>("Warning: no unit provided for sensor!"); } - - return result; } ipmi_ret_t populate_record_from_dbus(get_sdr::SensorDataFullRecordBody *body, @@ -905,26 +849,16 @@ ipmi_ret_t populate_record_from_dbus(get_sdr::SensorDataFullRecordBody *body, /* Functional sensor case */ if (isAnalogSensor(info->propertyInterfaces.begin()->first)) { - // Get bus - sd_bus *bus = ipmid_get_sd_bus_connection(); - dbus_interface_t iface; - - if (0 > find_openbmc_path(body->entity_id, &iface)) - return IPMI_CC_SENSOR_INVALID; body->sensor_units_1 = 0; // unsigned, no rate, no modifier, not a % /* Unit info */ - setUnitFieldsForObject(bus, iface, info, body); - - /* Modifiers to reading info */ - // Get scale - int64_t scale = getScaleForObject(bus, iface, info); + setUnitFieldsForObject(info, body); get_sdr::body::set_b(info->coefficientB, body); get_sdr::body::set_m(info->coefficientM, body); get_sdr::body::set_b_exp(info->exponentB, body); - get_sdr::body::set_r_exp(scale, body); + get_sdr::body::set_r_exp(info->exponentR, body); get_sdr::body::set_id_type(0b00, body); // 00 = unicode } |