#Example fan zone definitions for phosphor-fan-control #List the properties of the fan zones that are possible in the system. #The zones may be conditional based on certain conditions, such as #different chassis types or water cooled models. The fans themselves #are not listed in this file. They are in a separate YAML file so it #can be machine generated (i.e. from the MRW) if desired. #The general structure is a list of groups of zones, where a group #contains both the zones and the conditions required for the zones #to be valid #The cooling_profile is used along with the zone number to know #which fans in the fan yaml belong in this zone instance. For #example, a fan may only be in zone 0 if it's the air cooled version #of the system, but not with the water cooled version. In that #case, the fan yaml would have a cooling_profile of 'air' to match #the zone cooling profile. #- zone_conditions: # - name: [Name of a condition, if any. Valid names are TBD] # # zones: # - zone: [zone number] # cooling_profiles: # - [cooling profile] # initial_speed: [Speed to set the zone to when app starts] #Example: #- zone_conditions: # - name: air_cooled_chassis # # zones: # - zone: 0 # cooling_profiles: # - air # - all # initial_speed: 10500 # #- zone_conditions: # - name: water_and_air_cooled_chassis # # zones: # - zone: 0 # cooling_profiles: # - water # - all # initial_speed: 4000