Replace count_if with all_of in the property states match precondition
to stop iterating over the group members once a property state does not
match.
Include additional debug tracing when the precondition passes and fails
to help in determining where the precondition causes fans to be at full
speed.
Tested:
Verify debug traces align with precondition state
Change-Id: I1c3d8f096a645ac3bfcdfb7b9197682cf7ca52a0
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
| |
Each set speed event will contain a list of one-to-many actions to
perform for the given event group's property. This reduces the amount of
code generated and properly handles property changed events against the
group.
Change-Id: If2b8c0d0b8ecf6e1c974c43d96e1c6e9e952022b
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
A zone is actively controlling its fan speeds when all groups subscribed
to allow active control are set to true. The zone keeps a list of these
groups and their active allow state, if at anytime an action (or
precondition) sets a group's active state to false, any dynamic set
speed requests do not occur. Only requests to set the zone's fans to
full speed is allowed.
Related to this, the zone's target speed should only be updated when a
requested speed is successfully set.
Change-Id: Iec6f15346fee5a6c6046d5b00e949e46aef400b9
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
| |
Allows the complete removal of a set speed event from the zone. This is
done when any precondition defined for the event to be active is not
met any longer.
Change-Id: Idbec357f76f0fd7db9107e8c9d3e00461872c528
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
| |
The property state check precondition validates that each given property
matches the defined value. When all the precondition groups' property
states match, the given set speed event is initialized and activated
allowing the zone speeds to be active controlled.
Change-Id: Ic16a0e1fc584c6fa695e354fa80fb1993002ffc7
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
Any defined preconditions for a set speed event must be satisfied prior
to configuring the event parameters for fan control. These preconditions
will accept a list of group entries that include the value the group's
property must be to have the precondition met for that group. Once all
preconditions are met, the set speed event will be initialized and
become active.
Change-Id: Ia5555be55c5937c891af527bea63da1546655b2f
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|