* Add thermal control interface to zone objectsMatthew Barth2019-02-131-0/+5
| | | | | | | | | | | | | When in control mode, the thermal control interface and mode property are added to each zone object. The object path for each zone consists of the configured object path plus the zone number. Ex) /xyz/openbmc_project/control/thermal/0 Tested: After fan control is started in control mode, dbus interface exists Change-Id: I88578a7e0eb7c730ffaa4cfc10989e280dc1d46d Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
* Switch sd_event loops to sdeventplusWilliam A. Kennington III2018-10-291-2/+3
| | | | | | | | | This change is mostly focused around plumbing the sdeventplus::Event object everywhere and using the member functions provided for the event. No migration to the timer utility is performed yet. Change-Id: I912ab82bc081239d3b7c3cf7c5caca6742ef9c87 Signed-off-by: William A. Kennington III <wak@google.com>
* Use shared callMethod function in control managerMatthew Barth2018-05-171-5/+0
| | | | | | | | | | | | | To better handle exit/restart of the fan control application use the shared callMethod function to call systemd's startunit on the fan control ready target. This allows the fan control application to exit and restart quickly in its allowed attempts configured in systemd. Tested: StartUnit on fan control ready target works the same Change-Id: Idce2d8831b4e8de0ef181a0849587e465419f68c Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
* Timer to decrease fan speedsMatthew Barth2017-07-061-0/+2
| | | | | | | | | Create a repeating timer for decreasing fan speeds where the fan speeds in the zone are decreased when the timer expires and a decrease speed request exists with no increase request present or active. Change-Id: I419592f6f50c0ed524f8bf3ebf183854ab5ef2ea Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
* Only setup set speed events when not init modeMatthew Barth2017-05-311-11/+0
| | | | | Change-Id: Ia6987295a3eb4e23b9d6ae13a383e440386572de Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
* Add modes to phosphor-fan-controlMatt Spinler2017-05-161-1/+33
| | | | | | | | | | | | | | | phosphor-fan-control can behave differently based on its command line arguments --init: Set fans to full speed, delay for a configurable amount of time to allow fans to ramp up, start the fan control ready target, and then exit. --control: Start the control algorithm. Never exits. Will be started as part of the fan control ready target. Change-Id: I453daf8cc05a5c85a19c098e1cca64cac2ad9520 Signed-off-by: Matt Spinler <spinler@us.ibm.com>
* Fan control: Fill in Manager classMatt Spinler2017-04-271-0/+9
| | | | | | | | Create Zone objects for the fan zones defined in the definition data that meet all conditions. Change-Id: I9c29be93716cd137f1c714355a0bd2a1c93271cd Signed-off-by: Matt Spinler <spinler@us.ibm.com>
* Fan control: Add Manager class and fan dataMatt Spinler2017-04-261-0/+55