Properties hosted by a zone object need the ability to be set upon zone
initialization. This adds support to allow the zone configuration yaml
to contain what properties to set and with what values on a zone. The
parser updates to generate what uses this framework is in a followup
commit.
Change-Id: I9fd93746cc097f05869400451daff03cf3ef89b7
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Properties on the zone object require their event data to be stored for
retrieval when their value changes, which allows the use of the current
event handlers to update the cached value and trigger the event actions.
When any event is initialized, any signals where the match string is
empty performs a lookup for each group member to determine if they are
on the zone object. Each member found to be on the zone object is then
stored with the that event's data.
Tested:
Verified event data is stored for members on the zone object
Verified event initialization correctly accesses zone object
member's event data
Change-Id: Id34f60eb12330428eeb1041de4e9bd1a4a686f21
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
| |
This code is not compiled during the unit test run. The issue was
noticed trying to integrate into a real openbmc build.
Change-Id: I30b7afaf722b1a14e5ac3d5e93e13b59db48be7a
Signed-off-by: William A. Kennington III <wak@google.com>
|
|
|
|
|
|
|
|
|
|
| |
When the SdBusError exception was added, all sdbusplus::bus::call
function use required this exception be handled appropriately in each
case where it could occur. These changes are the result of handling the
possibility of this exception correctly within the fan applications.
Change-Id: I6ecef3008412b299a4fedbb13716f656cfbf1a90
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Fan control is required to be configured for all possible temperature
sensors within a machine type, however not every configuration of
that machine type contains all of those sensors. The trace removed here
was filling the journal with unnecessary entries for sensors that are
expected to not be present.
Tested:
Journal entry is not longer traced
Change-Id: Iccb85ae7e9463ee03522ce4efde6410ed14a76ca
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
All 3 fan applications - control, monitor, and presence
have cases where it is expected that a getProperty call
may fail because a sensor is missing. While the applications
already handle this, the InternalFailure exception that was
being thrown by the underlying call generates log entries
that make it look like something bad happened.
The custom exceptions now being thrown do not log anything on
creation, but store all of the failing information so that
any callers could still log the info if they wanted to.
Tested: Boot a water cooled Witherspoon and see the fan presence
and monitor applications not look like they are
failing. Boot a system without the fan hwmon running,
and see fan-control-init still show the fails.
Change-Id: Ifd8ad6e3deb492bbaf33f12c7258125dce1e5ea8
Signed-off-by: Matt Spinler <spinler@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
When an InterfacesRemoved signal is received for a subscribed object
path, each interface returned is checked against the interface which was
defined for each object on the event. When these are equal, the
interface (and all associated properties) are removed from the shared
cache of event properties.
Tested:
Manually added an InterfacesRemoved signal
Verified interface was removed from object path in cache
Change-Id: I348d82f14e0cfba2b18a81a9f54c6cb06b586797
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Retrieve the service names from the cached dataset within the zone for a
path and interface, updating the cache when not found. This is used when
initializing property values and service name owners.
Additional performance enhancements to use `GetSubTree` prior to
processing a set speed event will be included under
openbmc/openbmc#2911. This will keep unnecessary `GetSubTree` lookups
from occurring for paths/interfaces that don't exist to further improve
upon initializing properties fan control is defined to use.
Tested:
First path updates service name cache for all paths sharing the same
interface
First missing interface on a path updates service name cache for all
paths sharing that interface
Verify mapper lookups for X number of paths sharing the same
interface is reduced to (X-(X-1))
NameOwnerChanged events read/update the same set of service name
cache
Change-Id: Ia235b36ba5ae8cda38342d7521f3d87080c2970a
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
| |
When a property can not be found after receiving a property changed
signal include the path for the property on the journal entry.
Change-Id: Ie0151b943914e02d38bf89760f8a16dc530aa89e
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
| |
Resulting from a code review, remove the use of strcmp when comparing a
string to a const char*
Change-Id: Idcd3f99bf7ca0151f5f1b97c7ccc54d6e8c56f8e
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
| |
A NameOwnerChanged signal message provides three strings containing the
service name that has changed along with its old service owner name and
new service owner name. These names are then passed along to the handler
to find/update the group associated with the changed owner name.
Change-Id: I7d67883b010fec5b282bd00a4dcc29629486af00
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
| |
NameOwnerChanged signals will be used within fan control to configure
set speed events for when services providing parameters to the fan
control application have unexpectedly terminated.
Change-Id: I04f3c7ca2842732e33dc94b0280ad4483f7f1286
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Using a null dbus message to the event signal will perform the necessary
steps to initialize the event parameters using the given signal
handler's function directly.
i.e.) In the case for subscribing to PropertiesChanged signals,
initially the given property must be read. When the PropertiesChanged
signal struct is given a null message, it finds the property, reads the
value, and then can perform the given signal handler function directly.
This produces the same functional path as receiving a PropertiesChanged
signal containing the property value within the message.
Change-Id: I35575cfff66eb0305156be786cb1f5536d42bb1c
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Set speed events can not subscribe to InterfaceAdded signals for
properties that are created after fan control initializes the event. Fan
control subscribes to property changed signals for all events upon
startup where any properties that do not exist are unable to be
subscribed to and be notified when their property changes. Therefore,
subscribing to the InterfacesAdded signals for properties as well allows
any property defined within a set speed event that may not exist upon
starting the fan control application get added or updated when the
interface it resides on is added.
When a subscribed InterfacesAdded signal is caught, the same setProperty
handler function will be used to add the property value for the object
path, interface, and property name defined to be subscribed to for
property change signals.
Change-Id: If6fe97288140b83e2e2d735fdf61d52de1ec2e88
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
|
|
|
|
|
|
| |
Enable an action to be defined that sets the zone to a given speed when
a number of properties are set to a given value
Change-Id: I5252a20a24bdb14dee63080f2c08b080c82ad7e8
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|
|
Enable the control application to handle property changed signals to set
or update a cached set of these properties
Change-Id: Ib84ffe1e801ee7dd85d17fdbb122d124d307dbd3
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
|