* Enable setting/adjusting fan ceiling speedMatthew Barth2017-06-281-0/+109
| | | | | | | | | | | | | | | | | Set the default ceiling to be what's given as full speed and adjust the ceiling speed based on an average of a given set of sensor values. The ceiling is chosen from a given map's key transition values. The map consists of key, value pairs where each key is the sensor value transition point and the value is the ceiling speed for when that transition occurs. The previous key value is needed to determine the direction in which to chose the appropriate ceiling speed allowing a buffer zone between ceiling changes if defined to. Resolves openbmc/openbmc#1628 Change-Id: I7c9c553b5d0c3219c51b563aec7dd5d5f090916b Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
* Allow floor speed changes based on sensor valuesMatthew Barth2017-06-261-0/+50
| | | | | | | | | | Given a group of sensor values, the average of those sensor values will be used in selecting the floor speed for the zone. Each time the speed is set/updated, any speed requested lower than the current floor will be overwritten with the floor speed to not allow speeds below the floor. Change-Id: I4c8e8a2cd66892b9fdc2bc5643e907adddff51f8 Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
* Properties stored of different typesMatthew Barth2017-06-261-3/+6
| | | | | | | | Allow properties stored for processing events to be of types other than bool Change-Id: Ie1dde5aca562c9958bdff6fa3d1b19d3154b2c6d Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
* Add interface to uniquely identify propertiesMatthew Barth2017-06-261-0/+1
| | | | | | | | The interface is needed on the properties stored to uniquely identify each property used in events. Change-Id: Ia062f25514d7ed04ef1023a02eecad4738711ffb Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
* Add an active state for automatic fan controlMatthew Barth2017-05-311-1/+3
| | | | | | | | | | | | Each zone contains an active state that determines whether the automatic fan control algorithm is active and controlling the fan speeds dynamically or not. This will be used to determine if the fan speeds within the zone are set dynamically or rather held at another speed for a determined reason. Change-Id: I2f81de168c5f7d859b3ec917022c4749e1a28d4e Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
* Add setting zone speed actionMatthew Barth2017-05-311-0/+50
Enable an action to be defined that sets the zone to a given speed when a number of properties are set to a given value Change-Id: I5252a20a24bdb14dee63080f2c08b080c82ad7e8 Signed-off-by: Matthew Barth <msbarth@us.ibm.com>