Add target interface for fan control
Current fan control assumes the use of the FanSpeed interface for fan targets. For fans controlled by pwm, FanPwm interface is added. This commit adds "target_interface" config parameter, so that user can specify the interface for the fan targets. E.g. - inventory: /system/chassis/motherboard/fan0 cooling_zone: 0 cooling_profile: air sensors: - fan0 target_interface: xyz.openbmc_project.Control.FanPwm The config is optional and defaults to FanSpeed, so the current code will not be affected. Tested: Use this config on Romulus, ensures the fan control sets target on FanPwm interface and works fine. Change-Id: I73adccaa770d657b5d7aaeb307917f89588524de Signed-off-by: Lei YU <mine260309@gmail.com>
Diffstat (limited to 'control/example')
-rw-r--r--control/example/fans.yaml6
1 files changed, 5 insertions, 1 deletions
diff --git a/control/example/fans.yaml b/control/example/fans.yaml
index 629c502..2583256 100644
--- a/control/example/fans.yaml
+++ b/control/example/fans.yaml
@@ -9,12 +9,15 @@
# cooling_zone: [The cooling zone number for the fan]
# cooling_profile: [The cooling profile for the fan]
# sensors: [The list of sensors for this fan]
+# target_interface: [The interface implemented by the fan target.
+# Default is xyz.openbmc_project.Control.FanSpeed]
#The cooling zone, a number, and the cooling profile, a string,
#have to match the corresponding values in the fan zone yaml
#so the fans can be merged into the zone definition.
-#Example entries for 2 fan system:
+#Example entries for 2 fan system where fan0 uses default FanSpeed and
+#fan1 uses FanPwm:
#fans:
# - inventory: /system/chassis/motherboard/fan0
# cooling_zone: 0
@@ -26,3 +29,4 @@
# cooling_profile: air
# sensors:
# - fan1
+# target_interface: xyz.openbmc_project.Control.FanPwm