Decreases allowed based on all groups
For speed decreases to occur, all sensor groups involved with setting a net decrease delta must be below their given t-control low values for the associated zone. This handles the case where one or more sensor groups' temperatures stabilize above their t-control low value, but one or more other sensor groups' temperatures are below their t-control low value which would result in speed decrease requests that could eventually lead to fan speed oscillations. Resolves openbmc/openbmc#2710 Change-Id: I382de5d3f9c3e631a332d49dfcb06e705ff6fc17 Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
Diffstat (limited to 'control/actions.hpp')
-rw-r--r--control/actions.hpp58
1 files changed, 31 insertions, 27 deletions
diff --git a/control/actions.hpp b/control/actions.hpp
index 55c8af8..c7356ab 100644
--- a/control/actions.hpp
+++ b/control/actions.hpp
@@ -230,41 +230,45 @@ auto set_net_decrease_speed(T&& state, T&& factor, uint64_t speedDelta)
state = std::forward<T>(state)](auto& zone, auto& group)
{
auto netDelta = zone.getDecSpeedDelta();
- std::for_each(
- group.begin(),
- group.end(),
- [&zone, &state, &factor, &speedDelta, &netDelta](auto const& entry)
+ for (auto& entry : group)
+ {
+ try
{
- try
+ T value = zone.template getPropertyValue<T>(
+ entry.first,
+ std::get<intfPos>(entry.second),
+ std::get<propPos>(entry.second));
+ // TODO openbmc/phosphor-fan-presence#7 - Support possible
+ // state types for comparison
+ if (value < state)
{
- T value = zone.template getPropertyValue<T>(
- entry.first,
- std::get<intfPos>(entry.second),
- std::get<propPos>(entry.second));
- // TODO openbmc/phosphor-fan-presence#7 - Support possible
- // state types for comparison
- if (value < state)
+ if (netDelta == 0)
{
- if (netDelta == 0)
- {
- netDelta = ((state - value)/factor) * speedDelta;
- }
- else
- {
- // Decrease is the factor applied to the
- // difference times the given speed delta
- netDelta = std::min(
- netDelta,
- ((state - value)/factor) * speedDelta);
- }
+ netDelta = ((state - value)/factor) * speedDelta;
+ }
+ else
+ {
+ // Decrease is the factor applied to the
+ // difference times the given speed delta
+ netDelta = std::min(
+ netDelta,
+ ((state - value)/factor) * speedDelta);
}
}
- catch (const std::out_of_range& oore)
+ else
{
- // Property value not found, netDelta unchanged
+ // No decrease allowed for this group
+ netDelta = 0;
+ break;
}
}
- );
+ catch (const std::out_of_range& oore)
+ {
+ // Property value not found, netDelta unchanged
+ }
+ }
+ // Update group's decrease allowed state
+ zone.setDecreaseAllow(&group, !(netDelta == 0));
// Request speed decrease to occur on decrease interval
zone.requestSpeedDecrease(netDelta);
};