diff options
Diffstat (limited to 'xyz')
-rw-r--r-- | xyz/openbmc_project/Sensor/Threshold/Critical.interface.yaml | 18 | ||||
-rw-r--r-- | xyz/openbmc_project/Sensor/Threshold/Warning.interface.yaml | 18 |
2 files changed, 26 insertions, 10 deletions
diff --git a/xyz/openbmc_project/Sensor/Threshold/Critical.interface.yaml b/xyz/openbmc_project/Sensor/Threshold/Critical.interface.yaml index 548feb5..c575bb5 100644 --- a/xyz/openbmc_project/Sensor/Threshold/Critical.interface.yaml +++ b/xyz/openbmc_project/Sensor/Threshold/Critical.interface.yaml @@ -22,14 +22,22 @@ properties: type: int64 description: > The lower bound of the critical threshold. - - name: CriticalAlarm + - name: CriticalAlarmHigh type: boolean description: > - True if the sensor value has exceeded the defined bounds. - False if the sensor value has not exceeded the defined bounds. + True if the sensor value has exceeded the defined bound. + False if the sensor value has not exceeded the defined bound. - CriticalAlarm may be set to False to clear an alarm condition. - The behavior of setting CriticalAlarm to True is undefined. + CriticalAlarmHigh may be set to False to clear an alarm condition. + The behavior of setting CriticalAlarmHigh to True is undefined. + - name: CriticalAlarmLow + type: boolean + description: > + True if the sensor value has exceeded the defined bound. + False if the sensor value has not exceeded the defined bound. + + CriticalAlarmLow may be set to False to clear an alarm condition. + The behavior of setting CriticalAlarmLow to True is undefined. # vim: tabstop=8 expandtab shiftwidth=4 softtabstop=4 diff --git a/xyz/openbmc_project/Sensor/Threshold/Warning.interface.yaml b/xyz/openbmc_project/Sensor/Threshold/Warning.interface.yaml index f8ef993..9f4822b 100644 --- a/xyz/openbmc_project/Sensor/Threshold/Warning.interface.yaml +++ b/xyz/openbmc_project/Sensor/Threshold/Warning.interface.yaml @@ -23,13 +23,21 @@ properties: type: int64 description: > The lower bound of the warning threshold. - - name: WarningAlarm + - name: WarningAlarmHigh type: boolean description: > - True if the sensor value has exceeded the defined bounds. - False if the sensor value has not exceeded the defined bounds. + True if the sensor value has exceeded the defined bound. + False if the sensor value has not exceeded the defined bound. - WarningAlarm may be set to False to clear an alarm condition. - The behavior of setting WarningAlarm to True is undefined. + WarningAlarmHigh may be set to False to clear an alarm condition. + The behavior of setting WarningAlarmHigh to True is undefined. + - name: WarningAlarmLow + type: boolean + description: > + True if the sensor value has exceeded the defined bound. + False if the sensor value has not exceeded the defined bound. + + WarningAlarmLow may be set to False to clear an alarm condition. + The behavior of setting WarningAlarmLow to True is undefined. # vim: tabstop=8 expandtab shiftwidth=4 softtabstop=4 |