| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
I2c occ dbus objects path were their i2c addresses, e.g. 3_0050.
This does not indicate it's occ objects, and it does not work with
op-occ-disable/enable services, which searches "occ" key words in object
path.
So add "occ_" prefix for i2c occ dbus objects, e.g. occ_3_0050, to
indicate it's occ objects and work well with op-occ-disable/enable
services.
Change-Id: I21712f2fb7cf6138248f6986b84f99c90c3fa3a2
Signed-off-by: Lei YU <mine260309@gmail.com>
|
|
|
|
|
|
|
|
|
|
|
| |
1. Add unit tests for utils;
2. Put the common code shared by app and utest into a library, and link the
library to app and utest.
This eliminates the duplicated compiled objects.
3. Update .gitignore
Change-Id: I05ee93c2b23748a1e038eeec3534d49b94911366
Signed-off-by: Lei YU <mine260309@gmail.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
P8 system uses I2C OCC and it uses different driver for occ-hwmon.
Add `--enable-i2c-occ` configure option to enable the support.
It searches i2c device names in sysfs to get all occ-hwmon devices and
use the i2c device name to bind/unbind the driver.
The occ control object path for I2C OCC hwmon becomes something like
/org/open_power/control/3_0050, where 3_0050 is the i2c address.
Change-Id: I8b9d8d4429c563528dc88fb2679b265c53d7a2d5
Signed-off-by: Lei YU <mine260309@gmail.com>
|
|
|
|
|
|
|
|
|
|
| |
After detecting the error in the OCC, invokes OccReset command
in Host Control dbus object with the sensor ID of the failing OCC
Fixes openbmc/openbmc#1363
Change-Id: I608dbbb943d3b39d0709d6f350ab799e771a13e9
Signed-off-by: Vishwanatha Subbanna <vishwa@linux.vnet.ibm.com>
|
|
|
|
|
| |
Change-Id: I98d95020a2d01e281e5c8efa825d6b4bd4c6c160
Signed-off-by: Vishwanatha Subbanna <vishwa@linux.vnet.ibm.com>
|
|
Change-Id: Ie60aac151f5fd8ce091020ce756834e4877cbc93
Signed-off-by: Andrew Geissler <andrewg@us.ibm.com>
|