summaryrefslogtreecommitdiffstats
path: root/arch/x86/kernel/i8253.c
blob: e325cfe06401f61c1772b686705b762cdb6370d1 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
/*
 * 8253/PIT functions
 *
 */
#include <linux/clockchips.h>
#include <linux/init.h>
#include <linux/interrupt.h>
#include <linux/jiffies.h>
#include <linux/module.h>
#include <linux/spinlock.h>

#include <asm/smp.h>
#include <asm/delay.h>
#include <asm/i8253.h>
#include <asm/io.h>
#include <asm/hpet.h>

DEFINE_SPINLOCK(i8253_lock);
EXPORT_SYMBOL(i8253_lock);

#ifdef CONFIG_X86_32
static void pit_disable_clocksource(void);
#else
static inline void pit_disable_clocksource(void) { }
#endif

/*
 * HPET replaces the PIT, when enabled. So we need to know, which of
 * the two timers is used
 */
struct clock_event_device *global_clock_event;

/*
 * Initialize the PIT timer.
 *
 * This is also called after resume to bring the PIT into operation again.
 */
static void init_pit_timer(enum clock_event_mode mode,
			   struct clock_event_device *evt)
{
	spin_lock(&i8253_lock);

	switch(mode) {
	case CLOCK_EVT_MODE_PERIODIC:
		/* binary, mode 2, LSB/MSB, ch 0 */
		outb_pit(0x34, PIT_MODE);
		outb_pit(LATCH & 0xff , PIT_CH0);	/* LSB */
		outb_pit(LATCH >> 8 , PIT_CH0);		/* MSB */
		break;

	case CLOCK_EVT_MODE_SHUTDOWN:
	case CLOCK_EVT_MODE_UNUSED:
		if (evt->mode == CLOCK_EVT_MODE_PERIODIC ||
		    evt->mode == CLOCK_EVT_MODE_ONESHOT) {
			outb_pit(0x30, PIT_MODE);
			outb_pit(0, PIT_CH0);
			outb_pit(0, PIT_CH0);
		}
		pit_disable_clocksource();
		break;

	case CLOCK_EVT_MODE_ONESHOT:
		/* One shot setup */
		pit_disable_clocksource();
		outb_pit(0x38, PIT_MODE);
		break;

	case CLOCK_EVT_MODE_RESUME:
		/* Nothing to do here */
		break;
	}
	spin_unlock(&i8253_lock);
}

/*
 * Program the next event in oneshot mode
 *
 * Delta is given in PIT ticks
 */
static int pit_next_event(unsigned long delta, struct clock_event_device *evt)
{
	spin_lock(&i8253_lock);
	outb_pit(delta & 0xff , PIT_CH0);	/* LSB */
	outb_pit(delta >> 8 , PIT_CH0);		/* MSB */
	spin_unlock(&i8253_lock);

	return 0;
}

/*
 * On UP the PIT can serve all of the possible timer functions. On SMP systems
 * it can be solely used for the global tick.
 *
 * The profiling and update capabilities are switched off once the local apic is
 * registered. This mechanism replaces the previous #ifdef LOCAL_APIC -
 * !using_apic_timer decisions in do_timer_interrupt_hook()
 */
static struct clock_event_device pit_clockevent = {
	.name		= "pit",
	.features	= CLOCK_EVT_FEAT_PERIODIC | CLOCK_EVT_FEAT_ONESHOT,
	.set_mode	= init_pit_timer,
	.set_next_event = pit_next_event,
	.shift		= 32,
	.irq		= 0,
};

/*
 * Initialize the conversion factor and the min/max deltas of the clock event
 * structure and register the clock event source with the framework.
 */
void __init setup_pit_timer(void)
{
	/*
	 * Start pit with the boot cpu mask and make it global after the
	 * IO_APIC has been initialized.
	 */
	pit_clockevent.cpumask = cpumask_of_cpu(smp_processor_id());
	pit_clockevent.mult = div_sc(CLOCK_TICK_RATE, NSEC_PER_SEC, 32);
	pit_clockevent.max_delta_ns =
		clockevent_delta2ns(0x7FFF, &pit_clockevent);
	pit_clockevent.min_delta_ns =
		clockevent_delta2ns(0xF, &pit_clockevent);
	clockevents_register_device(&pit_clockevent);
	global_clock_event = &pit_clockevent;
}

#ifndef CONFIG_X86_64
/*
 * Since the PIT overflows every tick, its not very useful
 * to just read by itself. So use jiffies to emulate a free
 * running counter:
 */
static cycle_t pit_read(void)
{
	unsigned long flags;
	int count;
	u32 jifs;
	static int old_count;
	static u32 old_jifs;

	spin_lock_irqsave(&i8253_lock, flags);
	/*
	 * Although our caller may have the read side of xtime_lock,
	 * this is now a seqlock, and we are cheating in this routine
	 * by having side effects on state that we cannot undo if
	 * there is a collision on the seqlock and our caller has to
	 * retry.  (Namely, old_jifs and old_count.)  So we must treat
	 * jiffies as volatile despite the lock.  We read jiffies
	 * before latching the timer count to guarantee that although
	 * the jiffies value might be older than the count (that is,
	 * the counter may underflow between the last point where
	 * jiffies was incremented and the point where we latch the
	 * count), it cannot be newer.
	 */
	jifs = jiffies;
	outb_pit(0x00, PIT_MODE);	/* latch the count ASAP */
	count = inb_pit(PIT_CH0);	/* read the latched count */
	count |= inb_pit(PIT_CH0) << 8;

	/* VIA686a test code... reset the latch if count > max + 1 */
	if (count > LATCH) {
		outb_pit(0x34, PIT_MODE);
		outb_pit(LATCH & 0xff, PIT_CH0);
		outb_pit(LATCH >> 8, PIT_CH0);
		count = LATCH - 1;
	}

	/*
	 * It's possible for count to appear to go the wrong way for a
	 * couple of reasons:
	 *
	 *  1. The timer counter underflows, but we haven't handled the
	 *     resulting interrupt and incremented jiffies yet.
	 *  2. Hardware problem with the timer, not giving us continuous time,
	 *     the counter does small "jumps" upwards on some Pentium systems,
	 *     (see c't 95/10 page 335 for Neptun bug.)
	 *
	 * Previous attempts to handle these cases intelligently were
	 * buggy, so we just do the simple thing now.
	 */
	if (count > old_count && jifs == old_jifs) {
		count = old_count;
	}
	old_count = count;
	old_jifs = jifs;

	spin_unlock_irqrestore(&i8253_lock, flags);

	count = (LATCH - 1) - count;

	return (cycle_t)(jifs * LATCH) + count;
}

static struct clocksource clocksource_pit = {
	.name	= "pit",
	.rating = 110,
	.read	= pit_read,
	.mask	= CLOCKSOURCE_MASK(32),
	.mult	= 0,
	.shift	= 20,
};

static void pit_disable_clocksource(void)
{
	/*
	 * Use mult to check whether it is registered or not
	 */
	if (clocksource_pit.mult) {
		clocksource_unregister(&clocksource_pit);
		clocksource_pit.mult = 0;
	}
}

static int __init init_pit_clocksource(void)
{
	 /*
	  * Several reasons not to register PIT as a clocksource:
	  *
	  * - On SMP PIT does not scale due to i8253_lock
	  * - when HPET is enabled
	  * - when local APIC timer is active (PIT is switched off)
	  */
	if (num_possible_cpus() > 1 || is_hpet_enabled() ||
	    pit_clockevent.mode != CLOCK_EVT_MODE_PERIODIC)
		return 0;

	clocksource_pit.mult = clocksource_hz2mult(CLOCK_TICK_RATE,
						   clocksource_pit.shift);
	return clocksource_register(&clocksource_pit);
}
arch_initcall(init_pit_clocksource);

#endif
OpenPOWER on IntegriCloud