* [SCSI] libfc: register FC4 features with the FC switchJoe Eykholt2009-12-041-0/+12
| | | | | | | | | | | | | | | | | | Customers and certification tests have pointed out that we don't show up on the switch management software as an initiator. On some MDS switches 'show fcns database' command shows libfc initiators as 'fcp' not 'fcp:init' like other initiators. On others switches, I think the switch gets the features by doing a PRLI, but it may be only certain models or under certain configurations. Fix this by registering our FC4 features with the RFF_ID CT request after local port login and after the RFT_ID. Signed-off-by: Joe Eykholt <jeykholt@cisco.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* [SCSI] libfc: fix symbolic name registrations smashing skb dataJoe Eykholt2009-12-041-8/+9
| | | | | | | | | | | The strncpy for RSPN_ID and RSNN_NN requests was padding past the allocated frame size. Get the string length before filling in the ct header. Signed-off-by: Joe Eykholt <jeykholt@cisco.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* [SCSI] libfc: fix RNN_ID smashing skb payloadJoe Eykholt2009-12-041-1/+0
| | | | | | | | | | | | | The code that filled in the name server RNN_ID (register node name) request had somehow gotten a line in it from the RFT_ID code which copies 32 bytes of data over the relatively short payload. This caused some corruption and hangs. Simply deleted the extraneous line. Signed-off-by: Joe Eykholt <jeykholt@cisco.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* [SCSI] libfc: Register Symbolic Port Name (RSPN_ID)Chris Leech2009-12-041-0/+11
| | | | | | | | | Register the fc_host symbolic name as the symbolic port name with the fabric name server. Signed-off-by: Chris Leech <christopher.leech@intel.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* [SCSI] libfc: Register Symbolic Node Name (RSNN_NN)Chris Leech2009-12-041-0/+10
| | | | | | | | | Register the fc_host symbolic name as the symbolic node name with the fabric name server. Signed-off-by: Chris Leech <christopher.leech@intel.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* [SCSI] libfc: RNN_ID may be required before RSNN_NN with some switchesChris Leech2009-12-041-2/+2
| | | | | | | | | | | One could interpret FC-GS-5 to say that an explicit RNN_ID is required before RSNN_NN is allowed to succeed, which is why RNN_ID was not obsoleted along with RPN_ID acording to this document: ftp://ftp.t11.org/t11/member/fc/gs-5/05-546v2.pdf Signed-off-by: Chris Leech <christopher.leech@intel.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* [SCSI] libfc, libfcoe: FDISC ELS for NPIVChris Leech2009-12-041-0/+29
| | | | | | | | | | | Add FDISC ELS handling to libfc and libfcoe, treat it the same as FLOGI where appropriate. Add checking for NPIV support in the FLOGI LS_ACC service parameters. Signed-off-by: Chris Leech <christopher.leech@intel.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* [SCSI] libfc: send GPN_ID in reaction to single-port RSCNs.Joe Eykholt2009-09-101-2/+14
| | | | | | | | | | | | | | | | | | | | | | | | | | | When an RSCN indicates changes to individual remote ports, don't blindly log them out and then back in. Instead, determine whether they're still in the directory, by doing GPN_ID. If that is successful, call login, which will send ADISC and reverify, otherwise, call logoff. Perhaps we should just delete the rport, not send LOGO, but it seems safer. Also, fix a possible issue where if a mix of records in the RSCN cause us to queue disc_ports for disc_single and then we decide to do full rediscovery, we leak memory for those disc_ports queued. So, go through the list of disc_ports even if doing full discovery. Free the disc_ports in any case. If any of the disc_single() calls return error, do a full discovery. The ability to fill in GPN_ID requests was added to fc_ct_fill(). For this, it needs the FC_ID to be passed in as an arg. The did parameter for fc_elsct_send() is used for that, since the actual D_DID will always be 0xfffffc for all CT requests so far. Signed-off-by: Joe Eykholt <jeykholt@cisco.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* [SCSI] libfc: use ADISC to verify rport login stateJoe Eykholt2009-09-101-0/+21
| | | | | | | | | | | | | | | | | When rport_login is called on an rport that is already thought to be logged in, use ADISC. If that fails, redo PLOGI. This is less disruptive after fabric changes that don't affect the state of the target. Implement the sending of ADISC via fc_els_fill. Add ADISC state to the rport state machine. This is entered from READY and returns to READY after successful completion. If it fails, the rport is either logged off and deleted or re-does PLOGI. Signed-off-by: Joe Eykholt <jeykholt@cisco.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* [SCSI] libfc: change elsct to use FC_ID instead of rdataJoe Eykholt2009-09-101-21/+5
| | | | | | | | | | | | | | | | | tt.elsct_send is used by both FCP and by the rport state machine. After further patches, these two modules will use different structures for the remote port. So, change elsct_send to use the FC_ID instead of the fc_rport_priv as its argument. It currently only uses the FC_ID anyway. For CT requests the destination FC_ID is still implicitly 0xfffffc. After further patches the did arg on CT requests will be used to specify the FC_ID being inquired about for GPN_ID or other queries. Signed-off-by: Joe Eykholt <jeykholt@cisco.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* [SCSI] libfc: make fc_rport_priv the primary rport interface.Joe Eykholt2009-09-101-2/+5
| | | | | | | | | | | | | | | | | The rport and discovery modules deal with remote ports before fc_remote_port_add() can be done, because the full set of rport identifiers is not known at early stages. In preparation for splitting the fc_rport/fc_rport_priv allocation, make fc_rport_priv the primary interface for the remote port and discovery engines. The FCP / SCSI layers still deal with fc_rport and fc_rport_libfc_priv, however. Signed-off-by: Joe Eykholt <jeykholt@cisco.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
* libfc: Add runtime debugging with debug_logging module parameterRobert Love2009-06-211-2/+0
| | | | | | | | | | | | | | | | | | | | | | | | This patch adds the /sys/module/libfc/parameters/debug_logging file to sysfs as a module parameter. It accepts an integer bitmask for logging. Currently it supports: bit LSB 0 = general libfc debugging 1 = lport debugging 2 = disc debugging 3 = rport debugging 4 = fcp debugging 5 = EM debugging 6 = exch/seq debugging 7 = scsi logging (mostly error handling) the other bits are not used at this time. The patch converts all of the libfc source files to use these new macros and removes the old FC_DBG macro. Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
* [SCSI] libfc: A modular Fibre Channel libraryRobert Love2008-12-291-0/+309
libFC is composed of 4 blocks supported by an exchange manager and a framing library. The upper 4 layers are fc_lport, fc_disc, fc_rport and fc_fcp. A LLD that uses libfc could choose to either use libfc's block, or using the transport template defined in libfc.h, override one or more blocks with its own implementation. The EM (Exchange Manager) manages exhcanges/sequences for all commands- ELS, CT and FCP. The framing library frames ELS and CT commands. The fc_lport block manages the library's representation of the host's FC enabled ports. The fc_disc block manages discovery of targets as well as handling changes that occur in the FC fabric (via. RSCN events). The fc_rport block manages the library's representation of other entities in the FC fabric. Currently the library uses this block for targets, its peer when in point-to-point mode and the directory server, but can be extended for other entities if needed. The fc_fcp block interacts with the scsi-ml and handles all I/O. Signed-off-by: Robert Love <robert.w.love@intel.com> [jejb: added include of delay.h to fix ppc64 compile prob spotted by sfr] Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>