Change the interface used by set_voltage() to report the selected value
to the regulator core in terms of a selector used by list_voltage().
This allows the regulator core to know the voltage that was chosen
without having to do an explict get_voltage(), which would be much more
expensive as it will generally access hardware.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This patch includes below fixes based on Mark's comment.
- Return actual error if i2c_smbus_read_byte_data() fail
- Add spaces around bitwise AND operator(&) to improve readability
- Add comment to explain why we need to update voltage change control register
for LDO1 and LDO5
- Logging the value for diagnostics if chip reported incorrect voltage value
- Add __devinit annotation for setup_regulators()
- Show system control register1 value if the value is mismatched
- Logging the value for diagnostics if failed to detect device
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
|
|
This patch adds regulator drivers for National Semiconductors LP3972 PMIC.
This LP3972 PMIC controller has 3 DC/DC voltage converters and 5 low drop-out
(LDO) regulators. LP3972 PMIC controller uses I2C interface.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
|