summaryrefslogtreecommitdiffstats
path: root/drivers/hwmon/pmbus/adm1275.c
Commit message (Collapse)AuthorAgeFilesLines
* hwmon: (adm1275) Add support for ADM1075Guenter Roeck2012-03-181-4/+84
| | | | Signed-off-by: Guenter Roeck <linux@roeck-us.net>
* hwmon: (pmbus) Simplify remove functionsGuenter Roeck2012-03-181-7/+1
| | | | | | | | | Since devm_kzalloc() is now used to allocate driver memory, the client driver remove function has no purpose other than to call pmbus_do_remove(). This means we can get rid of it by redefining pmbus_do_remove() to use the same prototype, and pointing to it directly. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
* hwmon: (pmbus) Convert pmbus drivers to use devm_kzallocGuenter Roeck2012-03-181-13/+3
| | | | | | Marginally less code and eliminate the possibility of memory leaks. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
* hwmon: convert drivers/hwmon/* to use module_i2c_driver()Axel Lin2012-03-181-11/+1
| | | | | | | | | | | | | | | | | | This patch converts the drivers in drivers/hwmon/* to use the module_i2c_driver() macro which makes the code smaller and a bit simpler. Signed-off-by: Axel Lin <axel.lin@gmail.com> Cc: Corentin Labbe <corentin.labbe@geomatys.fr> Cc: Dirk Eibach <eibach@gdsys.de> Cc: "Mark M. Hoffman" <mhoffman@lightlink.com> Cc: Steve Glendinning <steve.glendinning@smsc.com> Cc: Riku Voipio <riku.voipio@iki.fi> Cc: Guillaume Ligneul <guillaume.ligneul@gmail.com> Cc: David George <david.george@ska.ac.za> Cc: "Hans J. Koch" <hjk@hansjkoch.de> Cc: Marc Hulsman <m.hulsman@tudelft.nl> Cc: Rudolf Marek <r.marek@assembler.cz> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
* hwmon: (pmbus/adm1275) Validate device IDGuenter Roeck2012-01-051-21/+50
| | | | | | | | Since manufacturer and device ID are known, read and validate it. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> [Dan Carpenter <dan.carpenter@oracle.com>: Fixed memory leak] Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
* hwmon: (pmbus) Always call _pmbus_read_byte in core driverGuenter Roeck2011-10-241-1/+1
| | | | | | | | | | | | | Always call _pmbus_read_byte() instead of pmbus_read_byte() in PMBus core driver. With this change, device specific read functions can be implemented for all registers. Since the device specific read_byte function is now always called, we need to be more careful with page validations. Only fail if the passed page number is larger than 0, since -1 means "current page". Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
* hwmon: (pmbus/adm1275) Add support for ADM1276Guenter Roeck2011-10-241-8/+51
| | | | | | | | ADM1276 is mostly compatible to ADM1275, with added support for input power measurement. Add support for it to the ADM1275 driver. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
* hwmon: (pmbus/adm1275) Add support for second current limitGuenter Roeck2011-10-241-7/+88
| | | | | | | | | | | | ADM1275 supports a second current limit, which can be configured as either lower or upper limit. Add support for it and report it as either lower or upper critical current limit. Also replace error return code EINVAL for unsupported pages with ENXIO as this is more appropriate for the observed condition. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
* hwmon: (pmbus) Don't return errors from driver remove functionsGuenter Roeck2011-10-241-3/+2
| | | | | | | | | | | | | | | | | | | | | Driver remove functions have an error return value, but rarely return an error in practice. If a driver does return an error from its remove function, the driver won't be unloaded and is expected to stay alive. pmbus_do_remove() is defined as returning an int, but always returns 0 (no error). Calling code passes that return value on to high level driver remove functions, but does not evaluate it and removes driver data even if pmbus_do_remove() returned an error (which it in practice never does). Even if this code could never cause a real problem, it is nevertheless conceptually wrong. To reduce confusion and simplify the code, change pmbus_do_remove() to be a void function, and have PMBus client drivers always return zero in their driver remove functions. Reported-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
* hwmon: (adm1275) Add support for peak attributesGuenter Roeck2011-07-281-0/+60
| | | | | | | Add support for voltage and current peak (historic maximum) attributes. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
* hwmon: (pmbus) Add support for VID output voltage modeGuenter Roeck2011-07-281-3/+3
| | | | | | | | | | | | In VID mode, output voltages are measured and reported as VID values, and have to be converted to voltages using VID conversion tables or functions. Support is added for VR11 only at this time. This patch enables support for PMBus devices supporting VID VR11 based output voltage selection such as NCP4200 and NCP4208. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
* hwmon: (pmbus) Move PMBus drivers to drivers/hwmon/pmbusGuenter Roeck2011-07-281-0/+131
Since the number of PMBus drivers is getting large, move them into directory drivers/hwmon/pmbus to improve readability and scalability. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>