summaryrefslogtreecommitdiffstats
path: root/fs/nfs/client.c
diff options
context:
space:
mode:
Diffstat (limited to 'fs/nfs/client.c')
-rw-r--r--fs/nfs/client.c29
1 files changed, 19 insertions, 10 deletions
diff --git a/fs/nfs/client.c b/fs/nfs/client.c
index a49f9feff776..a204484072f3 100644
--- a/fs/nfs/client.c
+++ b/fs/nfs/client.c
@@ -588,16 +588,6 @@ static int nfs_init_server(struct nfs_server *server, const struct nfs_mount_dat
server->namelen = data->namlen;
/* Create a client RPC handle for the NFSv3 ACL management interface */
nfs_init_server_aclclient(server);
- if (clp->cl_nfsversion == 3) {
- if (server->namelen == 0 || server->namelen > NFS3_MAXNAMLEN)
- server->namelen = NFS3_MAXNAMLEN;
- if (!(data->flags & NFS_MOUNT_NORDIRPLUS))
- server->caps |= NFS_CAP_READDIRPLUS;
- } else {
- if (server->namelen == 0 || server->namelen > NFS2_MAXNAMLEN)
- server->namelen = NFS2_MAXNAMLEN;
- }
-
dprintk("<-- nfs_init_server() = 0 [new %p]\n", clp);
return 0;
@@ -794,6 +784,16 @@ struct nfs_server *nfs_create_server(const struct nfs_mount_data *data,
error = nfs_probe_fsinfo(server, mntfh, &fattr);
if (error < 0)
goto error;
+ if (server->nfs_client->rpc_ops->version == 3) {
+ if (server->namelen == 0 || server->namelen > NFS3_MAXNAMLEN)
+ server->namelen = NFS3_MAXNAMLEN;
+ if (!(data->flags & NFS_MOUNT_NORDIRPLUS))
+ server->caps |= NFS_CAP_READDIRPLUS;
+ } else {
+ if (server->namelen == 0 || server->namelen > NFS2_MAXNAMLEN)
+ server->namelen = NFS2_MAXNAMLEN;
+ }
+
if (!(fattr.valid & NFS_ATTR_FATTR)) {
error = server->nfs_client->rpc_ops->getattr(server, mntfh, &fattr);
if (error < 0) {
@@ -984,6 +984,9 @@ struct nfs_server *nfs4_create_server(const struct nfs4_mount_data *data,
if (error < 0)
goto error;
+ if (server->namelen == 0 || server->namelen > NFS4_MAXNAMLEN)
+ server->namelen = NFS4_MAXNAMLEN;
+
BUG_ON(!server->nfs_client);
BUG_ON(!server->nfs_client->rpc_ops);
BUG_ON(!server->nfs_client->rpc_ops->file_inode_ops);
@@ -1056,6 +1059,9 @@ struct nfs_server *nfs4_create_referral_server(struct nfs_clone_mount *data,
if (error < 0)
goto error;
+ if (server->namelen == 0 || server->namelen > NFS4_MAXNAMLEN)
+ server->namelen = NFS4_MAXNAMLEN;
+
dprintk("Referral FSID: %llx:%llx\n",
(unsigned long long) server->fsid.major,
(unsigned long long) server->fsid.minor);
@@ -1115,6 +1121,9 @@ struct nfs_server *nfs_clone_server(struct nfs_server *source,
if (error < 0)
goto out_free_server;
+ if (server->namelen == 0 || server->namelen > NFS4_MAXNAMLEN)
+ server->namelen = NFS4_MAXNAMLEN;
+
dprintk("Cloned FSID: %llx:%llx\n",
(unsigned long long) server->fsid.major,
(unsigned long long) server->fsid.minor);
OpenPOWER on IntegriCloud