summaryrefslogtreecommitdiffstats
path: root/drivers/rtc/rtc-m41t93.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/rtc/rtc-m41t93.c')
-rw-r--r--drivers/rtc/rtc-m41t93.c46
1 files changed, 27 insertions, 19 deletions
diff --git a/drivers/rtc/rtc-m41t93.c b/drivers/rtc/rtc-m41t93.c
index 10f1c29436ec..efab3d48cb15 100644
--- a/drivers/rtc/rtc-m41t93.c
+++ b/drivers/rtc/rtc-m41t93.c
@@ -48,6 +48,7 @@ static inline int m41t93_set_reg(struct spi_device *spi, u8 addr, u8 data)
static int m41t93_set_time(struct device *dev, struct rtc_time *tm)
{
struct spi_device *spi = to_spi_device(dev);
+ int tmp;
u8 buf[9] = {0x80}; /* write cmd + 8 data bytes */
u8 * const data = &buf[1]; /* ptr to first data byte */
@@ -62,6 +63,30 @@ static int m41t93_set_time(struct device *dev, struct rtc_time *tm)
return -EINVAL;
}
+ tmp = spi_w8r8(spi, M41T93_REG_FLAGS);
+ if (tmp < 0)
+ return tmp;
+
+ if (tmp & M41T93_FLAG_OF) {
+ dev_warn(&spi->dev, "OF bit is set, resetting.\n");
+ m41t93_set_reg(spi, M41T93_REG_FLAGS, tmp & ~M41T93_FLAG_OF);
+
+ tmp = spi_w8r8(spi, M41T93_REG_FLAGS);
+ if (tmp < 0) {
+ return tmp;
+ } else if (tmp & M41T93_FLAG_OF) {
+ /* OF cannot be immediately reset: oscillator has to be
+ * restarted. */
+ u8 reset_osc = buf[M41T93_REG_ST_SEC] | M41T93_FLAG_ST;
+
+ dev_warn(&spi->dev,
+ "OF bit is still set, kickstarting clock.\n");
+ m41t93_set_reg(spi, M41T93_REG_ST_SEC, reset_osc);
+ reset_osc &= ~M41T93_FLAG_ST;
+ m41t93_set_reg(spi, M41T93_REG_ST_SEC, reset_osc);
+ }
+ }
+
data[M41T93_REG_SSEC] = 0;
data[M41T93_REG_ST_SEC] = bin2bcd(tm->tm_sec);
data[M41T93_REG_MIN] = bin2bcd(tm->tm_min);
@@ -89,10 +114,7 @@ static int m41t93_get_time(struct device *dev, struct rtc_time *tm)
1. halt bit (HT) is set: the clock is running but update of readout
registers has been disabled due to power failure. This is normal
case after poweron. Time is valid after resetting HT bit.
- 2. oscillator fail bit (OF) is set. Oscillator has be stopped and
- time is invalid:
- a) OF can be immeditely reset.
- b) OF cannot be immediately reset: oscillator has to be restarted.
+ 2. oscillator fail bit (OF) is set: time is invalid.
*/
tmp = spi_w8r8(spi, M41T93_REG_ALM_HOUR_HT);
if (tmp < 0)
@@ -110,21 +132,7 @@ static int m41t93_get_time(struct device *dev, struct rtc_time *tm)
if (tmp & M41T93_FLAG_OF) {
ret = -EINVAL;
- dev_warn(&spi->dev, "OF bit is set, resetting.\n");
- m41t93_set_reg(spi, M41T93_REG_FLAGS, tmp & ~M41T93_FLAG_OF);
-
- tmp = spi_w8r8(spi, M41T93_REG_FLAGS);
- if (tmp < 0)
- return tmp;
- else if (tmp & M41T93_FLAG_OF) {
- u8 reset_osc = buf[M41T93_REG_ST_SEC] | M41T93_FLAG_ST;
-
- dev_warn(&spi->dev,
- "OF bit is still set, kickstarting clock.\n");
- m41t93_set_reg(spi, M41T93_REG_ST_SEC, reset_osc);
- reset_osc &= ~M41T93_FLAG_ST;
- m41t93_set_reg(spi, M41T93_REG_ST_SEC, reset_osc);
- }
+ dev_warn(&spi->dev, "OF bit is set, write time to restart.\n");
}
if (tmp & M41T93_FLAG_BL)
OpenPOWER on IntegriCloud