summaryrefslogtreecommitdiffstats
path: root/drivers/md
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/md')
-rw-r--r--drivers/md/raid5.c69
1 files changed, 54 insertions, 15 deletions
diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c
index 2d2aaf6e98e2..2ae63c5b1c25 100644
--- a/drivers/md/raid5.c
+++ b/drivers/md/raid5.c
@@ -524,7 +524,11 @@ static void ops_run_io(struct stripe_head *sh, struct stripe_head_state *s)
bi->bi_end_io = raid5_end_read_request;
rcu_read_lock();
- rdev = rcu_dereference(conf->disks[i].rdev);
+ if (rw == READ &&
+ test_bit(R5_ReadRepl, &sh->dev[i].flags))
+ rdev = rcu_dereference(conf->disks[i].replacement);
+ else
+ rdev = rcu_dereference(conf->disks[i].rdev);
if (rdev && test_bit(Faulty, &rdev->flags))
rdev = NULL;
if (rdev)
@@ -1605,11 +1609,18 @@ static void raid5_end_read_request(struct bio * bi, int error)
BUG();
return;
}
+ if (test_bit(R5_ReadRepl, &sh->dev[i].flags))
+ rdev = conf->disks[i].replacement;
+ else
+ rdev = conf->disks[i].rdev;
if (uptodate) {
set_bit(R5_UPTODATE, &sh->dev[i].flags);
if (test_bit(R5_ReadError, &sh->dev[i].flags)) {
- rdev = conf->disks[i].rdev;
+ /* Note that this cannot happen on a
+ * replacement device. We just fail those on
+ * any error
+ */
printk_ratelimited(
KERN_INFO
"md/raid:%s: read error corrected"
@@ -1622,16 +1633,24 @@ static void raid5_end_read_request(struct bio * bi, int error)
clear_bit(R5_ReadError, &sh->dev[i].flags);
clear_bit(R5_ReWrite, &sh->dev[i].flags);
}
- if (atomic_read(&conf->disks[i].rdev->read_errors))
- atomic_set(&conf->disks[i].rdev->read_errors, 0);
+ if (atomic_read(&rdev->read_errors))
+ atomic_set(&rdev->read_errors, 0);
} else {
- const char *bdn = bdevname(conf->disks[i].rdev->bdev, b);
+ const char *bdn = bdevname(rdev->bdev, b);
int retry = 0;
- rdev = conf->disks[i].rdev;
clear_bit(R5_UPTODATE, &sh->dev[i].flags);
atomic_inc(&rdev->read_errors);
- if (conf->mddev->degraded >= conf->max_degraded)
+ if (test_bit(R5_ReadRepl, &sh->dev[i].flags))
+ printk_ratelimited(
+ KERN_WARNING
+ "md/raid:%s: read error on replacement device "
+ "(sector %llu on %s).\n",
+ mdname(conf->mddev),
+ (unsigned long long)(sh->sector
+ + rdev->data_offset),
+ bdn);
+ else if (conf->mddev->degraded >= conf->max_degraded)
printk_ratelimited(
KERN_WARNING
"md/raid:%s: read error not correctable "
@@ -1665,7 +1684,7 @@ static void raid5_end_read_request(struct bio * bi, int error)
md_error(conf->mddev, rdev);
}
}
- rdev_dec_pending(conf->disks[i].rdev, conf->mddev);
+ rdev_dec_pending(rdev, conf->mddev);
clear_bit(R5_LOCKED, &sh->dev[i].flags);
set_bit(STRIPE_HANDLE, &sh->state);
release_stripe(sh);
@@ -3036,7 +3055,19 @@ static void analyse_stripe(struct stripe_head *sh, struct stripe_head_state *s)
}
if (dev->written)
s->written++;
- rdev = rcu_dereference(conf->disks[i].rdev);
+ /* Prefer to use the replacement for reads, but only
+ * if it is recovered enough and has no bad blocks.
+ */
+ rdev = rcu_dereference(conf->disks[i].replacement);
+ if (rdev && !test_bit(Faulty, &rdev->flags) &&
+ rdev->recovery_offset >= sh->sector + STRIPE_SECTORS &&
+ !is_badblock(rdev, sh->sector, STRIPE_SECTORS,
+ &first_bad, &bad_sectors))
+ set_bit(R5_ReadRepl, &dev->flags);
+ else {
+ rdev = rcu_dereference(conf->disks[i].rdev);
+ clear_bit(R5_ReadRepl, &dev->flags);
+ }
if (rdev && test_bit(Faulty, &rdev->flags))
rdev = NULL;
if (rdev) {
@@ -3078,17 +3109,26 @@ static void analyse_stripe(struct stripe_head *sh, struct stripe_head_state *s)
set_bit(R5_Insync, &dev->flags);
if (rdev && test_bit(R5_WriteError, &dev->flags)) {
- clear_bit(R5_Insync, &dev->flags);
- if (!test_bit(Faulty, &rdev->flags)) {
+ /* This flag does not apply to '.replacement'
+ * only to .rdev, so make sure to check that*/
+ struct md_rdev *rdev2 = rcu_dereference(
+ conf->disks[i].rdev);
+ if (rdev2 == rdev)
+ clear_bit(R5_Insync, &dev->flags);
+ if (rdev2 && !test_bit(Faulty, &rdev2->flags)) {
s->handle_bad_blocks = 1;
- atomic_inc(&rdev->nr_pending);
+ atomic_inc(&rdev2->nr_pending);
} else
clear_bit(R5_WriteError, &dev->flags);
}
if (rdev && test_bit(R5_MadeGood, &dev->flags)) {
- if (!test_bit(Faulty, &rdev->flags)) {
+ /* This flag does not apply to '.replacement'
+ * only to .rdev, so make sure to check that*/
+ struct md_rdev *rdev2 = rcu_dereference(
+ conf->disks[i].rdev);
+ if (rdev2 && !test_bit(Faulty, &rdev2->flags)) {
s->handle_bad_blocks = 1;
- atomic_inc(&rdev->nr_pending);
+ atomic_inc(&rdev2->nr_pending);
} else
clear_bit(R5_MadeGood, &dev->flags);
}
@@ -4220,7 +4260,6 @@ static int retry_aligned_read(struct r5conf *conf, struct bio *raid_bio)
return handled;
}
- set_bit(R5_ReadError, &sh->dev[dd_idx].flags);
if (!add_stripe_bio(sh, raid_bio, dd_idx, 0)) {
release_stripe(sh);
raid5_set_bi_hw_segments(raid_bio, scnt);
OpenPOWER on IntegriCloud