summaryrefslogtreecommitdiffstats
path: root/arch/s390/Kconfig
diff options
context:
space:
mode:
Diffstat (limited to 'arch/s390/Kconfig')
-rw-r--r--arch/s390/Kconfig51
1 files changed, 39 insertions, 12 deletions
diff --git a/arch/s390/Kconfig b/arch/s390/Kconfig
index 583d9ff0a571..eaed402ad346 100644
--- a/arch/s390/Kconfig
+++ b/arch/s390/Kconfig
@@ -22,11 +22,15 @@ config RWSEM_XCHGADD_ALGORITHM
bool
default y
-config GENERIC_HWEIGHT
+config ARCH_HAS_ILOG2_U32
bool
- default y
+ default n
+
+config ARCH_HAS_ILOG2_U64
+ bool
+ default n
-config GENERIC_CALIBRATE_DELAY
+config GENERIC_HWEIGHT
bool
default y
@@ -126,6 +130,31 @@ config AUDIT_ARCH
bool
default y
+config S390_SWITCH_AMODE
+ bool "Switch kernel/user addressing modes"
+ help
+ This option allows to switch the addressing modes of kernel and user
+ space. The kernel parameter switch_amode=on will enable this feature,
+ default is disabled. Enabling this (via kernel parameter) on machines
+ earlier than IBM System z9-109 EC/BC will reduce system performance.
+
+ Note that this option will also be selected by selecting the execute
+ protection option below. Enabling the execute protection via the
+ noexec kernel parameter will also switch the addressing modes,
+ independent of the switch_amode kernel parameter.
+
+
+config S390_EXEC_PROTECT
+ bool "Data execute protection"
+ select S390_SWITCH_AMODE
+ help
+ This option allows to enable a buffer overflow protection for user
+ space programs and it also selects the addressing mode option above.
+ The kernel parameter noexec=on will enable this feature and also
+ switch the addressing modes, default is disabled. Enabling this (via
+ kernel parameter) on machines earlier than IBM System z9-109 EC/BC
+ will reduce system performance.
+
comment "Code generation options"
choice
@@ -233,8 +262,14 @@ config WARN_STACK_SIZE
This allows you to specify the maximum frame size a function may
have without the compiler complaining about it.
+config ARCH_POPULATES_NODE_MAP
+ def_bool y
+
source "mm/Kconfig"
+config HOLES_IN_ZONE
+ def_bool y
+
comment "I/O subsystem configuration"
config MACHCHK_WARNING
@@ -258,14 +293,6 @@ config QDIO
If unsure, say Y.
-config QDIO_PERF_STATS
- bool "Performance statistics in /proc"
- depends on QDIO
- help
- Say Y here to get performance statistics in /proc/qdio_perf
-
- If unsure, say N.
-
config QDIO_DEBUG
bool "Extended debugging information"
depends on QDIO
@@ -401,7 +428,7 @@ config APPLDATA_BASE
config APPLDATA_MEM
tristate "Monitor memory management statistics"
- depends on APPLDATA_BASE
+ depends on APPLDATA_BASE && VM_EVENT_COUNTERS
help
This provides memory management related data to the Linux - VM Monitor
Stream, like paging/swapping rate, memory utilisation, etc.
OpenPOWER on IntegriCloud