summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/adt747019
1 files changed, 8 insertions, 11 deletions
diff --git a/Documentation/hwmon/adt7470 b/Documentation/hwmon/adt7470
index 75d13ca147cc..8ce4aa0a0f55 100644
--- a/Documentation/hwmon/adt7470
+++ b/Documentation/hwmon/adt7470
@@ -31,15 +31,11 @@ Each of the measured inputs (temperature, fan speed) has corresponding high/low
limit values. The ADT7470 will signal an ALARM if any measured value exceeds
either limit.
-The ADT7470 DOES NOT sample all inputs continuously. A single pin on the
-ADT7470 is connected to a multitude of thermal diodes, but the chip must be
-instructed explicitly to read the multitude of diodes. If you want to use
-automatic fan control mode, you must manually read any of the temperature
-sensors or the fan control algorithm will not run. The chip WILL NOT DO THIS
-AUTOMATICALLY; this must be done from userspace. This may be a bug in the chip
-design, given that many other AD chips take care of this. The driver will not
-read the registers more often than once every 5 seconds. Further,
-configuration data is only read once per minute.
+The ADT7470 samples all inputs continuously. A kernel thread is started up for
+the purpose of periodically querying the temperature sensors, thus allowing the
+automatic fan pwm control to set the fan speed. The driver will not read the
+registers more often than once every 5 seconds. Further, configuration data is
+only read once per minute.
Special Features
----------------
@@ -72,5 +68,6 @@ pwm#_auto_point2_temp.
Notes
-----
-As stated above, the temperature inputs must be read periodically from
-userspace in order for the automatic pwm algorithm to run.
+The temperature inputs no longer need to be read periodically from userspace in
+order for the automatic pwm algorithm to run. This was the case for earlier
+versions of the driver.
OpenPOWER on IntegriCloud