summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/clock
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/devicetree/bindings/clock')
-rw-r--r--Documentation/devicetree/bindings/clock/clock-bindings.txt36
1 files changed, 36 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/clock/clock-bindings.txt b/Documentation/devicetree/bindings/clock/clock-bindings.txt
index f15787817d6b..06fc6d541c89 100644
--- a/Documentation/devicetree/bindings/clock/clock-bindings.txt
+++ b/Documentation/devicetree/bindings/clock/clock-bindings.txt
@@ -131,3 +131,39 @@ clock signal, and a UART.
("pll" and "pll-switched").
* The UART has its baud clock connected the external oscillator and its
register clock connected to the PLL clock (the "pll-switched" signal)
+
+==Assigned clock parents and rates==
+
+Some platforms may require initial configuration of default parent clocks
+and clock frequencies. Such a configuration can be specified in a device tree
+node through assigned-clocks, assigned-clock-parents and assigned-clock-rates
+properties. The assigned-clock-parents property should contain a list of parent
+clocks in form of phandle and clock specifier pairs, the assigned-clock-parents
+property the list of assigned clock frequency values - corresponding to clocks
+listed in the assigned-clocks property.
+
+To skip setting parent or rate of a clock its corresponding entry should be
+set to 0, or can be omitted if it is not followed by any non-zero entry.
+
+ uart@a000 {
+ compatible = "fsl,imx-uart";
+ reg = <0xa000 0x1000>;
+ ...
+ clocks = <&osc 0>, <&pll 1>;
+ clock-names = "baud", "register";
+
+ assigned-clocks = <&clkcon 0>, <&pll 2>;
+ assigned-clock-parents = <&pll 2>;
+ assigned-clock-rates = <0>, <460800>;
+ };
+
+In this example the <&pll 2> clock is set as parent of clock <&clkcon 0> and
+the <&pll 2> clock is assigned a frequency value of 460800 Hz.
+
+Configuring a clock's parent and rate through the device node that consumes
+the clock can be done only for clocks that have a single user. Specifying
+conflicting parent or rate configuration in multiple consumer nodes for
+a shared clock is forbidden.
+
+Configuration of common clocks, which affect multiple consumer devices can
+be similarly specified in the clock provider node.
OpenPOWER on IntegriCloud