summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/ABI')
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio32
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-adc-hi843543
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-chemical-vz89x7
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x9
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-meas-spec8
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-trigger-sysfs22
6 files changed, 121 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
index 42d360fe66a5..0439c2aaf741 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio
+++ b/Documentation/ABI/testing/sysfs-bus-iio
@@ -581,6 +581,7 @@ What: /sys/.../iio:deviceX/events/in_voltageY_supply_thresh_rising_en
What: /sys/.../iio:deviceX/events/in_voltageY_supply_thresh_falling_en
What: /sys/.../iio:deviceX/events/in_voltageY_thresh_rising_en
What: /sys/.../iio:deviceX/events/in_voltageY_thresh_falling_en
+What: /sys/.../iio:deviceX/events/in_voltageY_thresh_either_en
What: /sys/.../iio:deviceX/events/in_tempY_thresh_rising_en
What: /sys/.../iio:deviceX/events/in_tempY_thresh_falling_en
KernelVersion: 2.6.37
@@ -1459,3 +1460,34 @@ Description:
measurements and return the average value as output data. Each
value resulted from <type>[_name]_oversampling_ratio measurements
is considered as one sample for <type>[_name]_sampling_frequency.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_concentration_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_concentrationX_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_concentrationX_co2_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_concentration_voc_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_concentrationX_voc_raw
+KernelVersion: 4.3
+Contact: linux-iio@vger.kernel.org
+Description:
+ Raw (unscaled no offset etc.) percentage reading of a substance.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_resistance_raw
+What: /sys/bus/iio/devices/iio:deviceX/in_resistanceX_raw
+What: /sys/bus/iio/devices/iio:deviceX/out_resistance_raw
+What: /sys/bus/iio/devices/iio:deviceX/out_resistanceX_raw
+KernelVersion: 4.3
+Contact: linux-iio@vger.kernel.org
+Description:
+ Raw (unscaled no offset etc.) resistance reading that can be processed
+ into an ohm value.
+
+What: /sys/bus/iio/devices/iio:deviceX/heater_enable
+KernelVersion: 4.1.0
+Contact: linux-iio@vger.kernel.org
+Description:
+ '1' (enable) or '0' (disable) specifying the enable
+ of heater function. Same reading values apply
+ This ABI is especially applicable for humidity sensors
+ to heatup the device and get rid of any condensation
+ in some humidity environment
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435 b/Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435
new file mode 100644
index 000000000000..f30b4c424fb6
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435
@@ -0,0 +1,43 @@
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode
+Date: August 2015
+KernelVersion: 4.2.0
+Contact: source@cogentembedded.com
+Description:
+ Program sensor type for threshold detector inputs.
+ Could be either "GND-Open" or "Supply-Open" mode. Y is a
+ threshold detector input channel. Channels 0..7, 8..15, 16..23
+ and 24..31 has common sensor types.
+
+What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value
+Date: August 2015
+KernelVersion: 4.2.0
+Contact: source@cogentembedded.com
+Description:
+ Channel Y low voltage threshold. If sensor input voltage goes lower then
+ this value then the threshold falling event is pushed.
+ Depending on in_voltageY_sensing_mode the low voltage threshold
+ is separately set for "GND-Open" and "Supply-Open" modes.
+ Channels 0..31 have common low threshold values, but could have different
+ sensing_modes.
+ The low voltage threshold range is between 2..21V.
+ Hysteresis between low and high thresholds can not be lower then 2 and
+ can not be odd.
+ If falling threshold results hysteresis to odd value then rising
+ threshold is automatically subtracted by one.
+
+What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value
+Date: August 2015
+KernelVersion: 4.2.0
+Contact: source@cogentembedded.com
+Description:
+ Channel Y high voltage threshold. If sensor input voltage goes higher then
+ this value then the threshold rising event is pushed.
+ Depending on in_voltageY_sensing_mode the high voltage threshold
+ is separately set for "GND-Open" and "Supply-Open" modes.
+ Channels 0..31 have common high threshold values, but could have different
+ sensing_modes.
+ The high voltage threshold range is between 3..22V.
+ Hysteresis between low and high thresholds can not be lower then 2 and
+ can not be odd.
+ If rising threshold results hysteresis to odd value then falling
+ threshold is automatically appended by one.
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-chemical-vz89x b/Documentation/ABI/testing/sysfs-bus-iio-chemical-vz89x
new file mode 100644
index 000000000000..c0c1ea924535
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-chemical-vz89x
@@ -0,0 +1,7 @@
+What: /sys/bus/iio/devices/iio:deviceX/in_concentration_VOC_short_raw
+Date: September 2015
+KernelVersion: 4.3
+Contact: Matt Ranostay <mranostay@gmail.com>
+Description:
+ Get the raw calibration VOC value from the sensor.
+ This value has little application outside of calibration.
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x b/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x
new file mode 100644
index 000000000000..b72bb62552cf
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x
@@ -0,0 +1,9 @@
+What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw
+What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available
+KernelVersion: 4.3
+Contact: linux-iio@vger.kernel.org
+Description:
+ Controls the heater device within the humidity sensor to get
+ rid of excess condensation.
+
+ Valid control values are 0 = OFF, and 1 = ON.
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-meas-spec b/Documentation/ABI/testing/sysfs-bus-iio-meas-spec
new file mode 100644
index 000000000000..1a6265e92e2f
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-meas-spec
@@ -0,0 +1,8 @@
+What: /sys/bus/iio/devices/iio:deviceX/battery_low
+KernelVersion: 4.1.0
+Contact: linux-iio@vger.kernel.org
+Description:
+ Reading returns either '1' or '0'. '1' means that the
+ battery level supplied to sensor is below 2.25V.
+ This ABI is available for tsys02d, htu21, ms8607
+ This ABI is available for htu21, ms8607
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-trigger-sysfs b/Documentation/ABI/testing/sysfs-bus-iio-trigger-sysfs
index bbb039237a25..04ac62305018 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio-trigger-sysfs
+++ b/Documentation/ABI/testing/sysfs-bus-iio-trigger-sysfs
@@ -18,3 +18,25 @@ Description:
trigger. In order to associate the trigger with an IIO device
one should write this name string to
/sys/bus/iio/devices/iio:deviceY/trigger/current_trigger.
+
+What: /sys/bus/iio/devices/iio_sysfs_trigger/add_trigger
+KernelVersion: 2.6.39
+Contact: linux-iio@vger.kernel.org
+Description:
+ This attribute is provided by the iio-trig-sysfs stand-alone
+ driver and it is used to activate the creation of a new trigger.
+ In order to achieve this, one should write a positive integer
+ into the associated file, which will serve as the id of the
+ trigger. If the trigger with the specified id is already present
+ in the system, an invalid argument message will be returned.
+
+What: /sys/bus/iio/devices/iio_sysfs_trigger/remove_trigger
+KernelVersion: 2.6.39
+Contact: linux-iio@vger.kernel.org
+Description:
+ This attribute is used to unregister and delete a previously
+ created trigger from the list of available triggers. In order to
+ achieve this, one should write a positive integer into the
+ associated file, representing the id of the trigger that needs
+ to be removed. If the trigger can't be found, an invalid
+ argument message will be returned to the user.
OpenPOWER on IntegriCloud