summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--drivers/clocksource/timer-atmel-pit.c41
1 files changed, 18 insertions, 23 deletions
diff --git a/drivers/clocksource/timer-atmel-pit.c b/drivers/clocksource/timer-atmel-pit.c
index c0304ff608b0..58753223585b 100644
--- a/drivers/clocksource/timer-atmel-pit.c
+++ b/drivers/clocksource/timer-atmel-pit.c
@@ -90,33 +90,27 @@ static cycle_t read_pit_clk(struct clocksource *cs)
return elapsed;
}
+static int pit_clkevt_shutdown(struct clock_event_device *dev)
+{
+ struct pit_data *data = clkevt_to_pit_data(dev);
+
+ /* disable irq, leaving the clocksource active */
+ pit_write(data->base, AT91_PIT_MR, (data->cycle - 1) | AT91_PIT_PITEN);
+ return 0;
+}
+
/*
* Clockevent device: interrupts every 1/HZ (== pit_cycles * MCK/16)
*/
-static void
-pit_clkevt_mode(enum clock_event_mode mode, struct clock_event_device *dev)
+static int pit_clkevt_set_periodic(struct clock_event_device *dev)
{
struct pit_data *data = clkevt_to_pit_data(dev);
- switch (mode) {
- case CLOCK_EVT_MODE_PERIODIC:
- /* update clocksource counter */
- data->cnt += data->cycle * PIT_PICNT(pit_read(data->base, AT91_PIT_PIVR));
- pit_write(data->base, AT91_PIT_MR,
- (data->cycle - 1) | AT91_PIT_PITEN | AT91_PIT_PITIEN);
- break;
- case CLOCK_EVT_MODE_ONESHOT:
- BUG();
- /* FALLTHROUGH */
- case CLOCK_EVT_MODE_SHUTDOWN:
- case CLOCK_EVT_MODE_UNUSED:
- /* disable irq, leaving the clocksource active */
- pit_write(data->base, AT91_PIT_MR,
- (data->cycle - 1) | AT91_PIT_PITEN);
- break;
- case CLOCK_EVT_MODE_RESUME:
- break;
- }
+ /* update clocksource counter */
+ data->cnt += data->cycle * PIT_PICNT(pit_read(data->base, AT91_PIT_PIVR));
+ pit_write(data->base, AT91_PIT_MR,
+ (data->cycle - 1) | AT91_PIT_PITEN | AT91_PIT_PITIEN);
+ return 0;
}
static void at91sam926x_pit_suspend(struct clock_event_device *cedev)
@@ -162,7 +156,7 @@ static irqreturn_t at91sam926x_pit_interrupt(int irq, void *dev_id)
WARN_ON_ONCE(!irqs_disabled());
/* The PIT interrupt may be disabled, and is shared */
- if ((data->clkevt.mode == CLOCK_EVT_MODE_PERIODIC) &&
+ if (clockevent_state_periodic(&data->clkevt) &&
(pit_read(data->base, AT91_PIT_SR) & AT91_PIT_PITS)) {
unsigned nr_ticks;
@@ -227,7 +221,8 @@ static void __init at91sam926x_pit_common_init(struct pit_data *data)
data->clkevt.rating = 100;
data->clkevt.cpumask = cpumask_of(0);
- data->clkevt.set_mode = pit_clkevt_mode;
+ data->clkevt.set_state_shutdown = pit_clkevt_shutdown;
+ data->clkevt.set_state_periodic = pit_clkevt_set_periodic;
data->clkevt.resume = at91sam926x_pit_resume;
data->clkevt.suspend = at91sam926x_pit_suspend;
clockevents_register_device(&data->clkevt);
OpenPOWER on IntegriCloud