summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--drivers/acpi/acpica/evregion.c61
1 files changed, 21 insertions, 40 deletions
diff --git a/drivers/acpi/acpica/evregion.c b/drivers/acpi/acpica/evregion.c
index 8ae8f5b33bd9..cea14d6fc76c 100644
--- a/drivers/acpi/acpica/evregion.c
+++ b/drivers/acpi/acpica/evregion.c
@@ -54,7 +54,8 @@ extern u8 acpi_gbl_default_address_spaces[];
/* Local prototypes */
-static void acpi_ev_orphan_ec_reg_method(void);
+static void
+acpi_ev_orphan_ec_reg_method(struct acpi_namespace_node *ec_device_node);
static acpi_status
acpi_ev_reg_run(acpi_handle obj_handle,
@@ -612,7 +613,7 @@ acpi_ev_execute_reg_methods(struct acpi_namespace_node *node,
/* Special case for EC: handle "orphan" _REG methods with no region */
if (space_id == ACPI_ADR_SPACE_EC) {
- acpi_ev_orphan_ec_reg_method();
+ acpi_ev_orphan_ec_reg_method(node);
}
return_ACPI_STATUS(status);
@@ -681,7 +682,7 @@ acpi_ev_reg_run(acpi_handle obj_handle,
*
* FUNCTION: acpi_ev_orphan_ec_reg_method
*
- * PARAMETERS: None
+ * PARAMETERS: ec_device_node - Namespace node for an EC device
*
* RETURN: None
*
@@ -693,37 +694,27 @@ acpi_ev_reg_run(acpi_handle obj_handle,
* detected by providing a _REG method object underneath the
* Embedded Controller device."
*
- * To quickly access the EC device, we use the EC_ID that appears
- * within the ECDT. Otherwise, we would need to perform a time-
- * consuming namespace walk, executing _HID methods to find the
- * EC device.
+ * To quickly access the EC device, we use the ec_device_node used
+ * during EC handler installation. Otherwise, we would need to
+ * perform a time consuming namespace walk, executing _HID
+ * methods to find the EC device.
+ *
+ * MUTEX: Assumes the namespace is locked
*
******************************************************************************/
-static void acpi_ev_orphan_ec_reg_method(void)
+static void
+acpi_ev_orphan_ec_reg_method(struct acpi_namespace_node *ec_device_node)
{
- struct acpi_table_ecdt *table;
+ acpi_handle reg_method;
+ struct acpi_namespace_node *next_node;
acpi_status status;
struct acpi_object_list args;
union acpi_object objects[2];
- struct acpi_namespace_node *ec_device_node;
- struct acpi_namespace_node *reg_method;
- struct acpi_namespace_node *next_node;
ACPI_FUNCTION_TRACE(ev_orphan_ec_reg_method);
- /* Get the ECDT (if present in system) */
-
- status = acpi_get_table(ACPI_SIG_ECDT, 0,
- ACPI_CAST_INDIRECT_PTR(struct acpi_table_header,
- &table));
- if (ACPI_FAILURE(status)) {
- return_VOID;
- }
-
- /* We need a valid EC_ID string */
-
- if (!(*table->id)) {
+ if (!ec_device_node) {
return_VOID;
}
@@ -731,22 +722,11 @@ static void acpi_ev_orphan_ec_reg_method(void)
(void)acpi_ut_release_mutex(ACPI_MTX_NAMESPACE);
- /* Get a handle to the EC device referenced in the ECDT */
-
- status = acpi_get_handle(NULL,
- ACPI_CAST_PTR(char, table->id),
- ACPI_CAST_PTR(acpi_handle, &ec_device_node));
- if (ACPI_FAILURE(status)) {
- goto exit;
- }
-
/* Get a handle to a _REG method immediately under the EC device */
- status = acpi_get_handle(ec_device_node,
- METHOD_NAME__REG, ACPI_CAST_PTR(acpi_handle,
- &reg_method));
+ status = acpi_get_handle(ec_device_node, METHOD_NAME__REG, &reg_method);
if (ACPI_FAILURE(status)) {
- goto exit;
+ goto exit; /* There is no _REG method present */
}
/*
@@ -754,19 +734,20 @@ static void acpi_ev_orphan_ec_reg_method(void)
* this scope with the Embedded Controller space ID. Otherwise, it
* will already have been executed. Note, this allows for Regions
* with other space IDs to be present; but the code below will then
- * execute the _REG method with the EC space ID argument.
+ * execute the _REG method with the embedded_control space_ID argument.
*/
next_node = acpi_ns_get_next_node(ec_device_node, NULL);
while (next_node) {
if ((next_node->type == ACPI_TYPE_REGION) &&
(next_node->object) &&
(next_node->object->region.space_id == ACPI_ADR_SPACE_EC)) {
- goto exit; /* Do not execute _REG */
+ goto exit; /* Do not execute the _REG */
}
+
next_node = acpi_ns_get_next_node(ec_device_node, next_node);
}
- /* Evaluate the _REG(EC,Connect) method */
+ /* Evaluate the _REG(embedded_control,Connect) method */
args.count = 2;
args.pointer = objects;
OpenPOWER on IntegriCloud