summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--include/linux/ieee80211.h11
-rw-r--r--net/mac80211/ieee80211_i.h6
-rw-r--r--net/mac80211/ieee80211_sta.c69
3 files changed, 67 insertions, 19 deletions
diff --git a/include/linux/ieee80211.h b/include/linux/ieee80211.h
index ecd61e8438a5..272f8c8c90da 100644
--- a/include/linux/ieee80211.h
+++ b/include/linux/ieee80211.h
@@ -227,6 +227,17 @@ struct ieee80211_cts {
#define WLAN_CAPABILITY_SHORT_SLOT_TIME (1<<10)
#define WLAN_CAPABILITY_DSSS_OFDM (1<<13)
+/* 802.11g ERP information element */
+#define WLAN_ERP_NON_ERP_PRESENT (1<<0)
+#define WLAN_ERP_USE_PROTECTION (1<<1)
+#define WLAN_ERP_BARKER_PREAMBLE (1<<2)
+
+/* WLAN_ERP_BARKER_PREAMBLE values */
+enum {
+ WLAN_ERP_PREAMBLE_SHORT = 0,
+ WLAN_ERP_PREAMBLE_LONG = 1,
+};
+
/* Status codes */
enum ieee80211_statuscode {
WLAN_STATUS_SUCCESS = 0,
diff --git a/net/mac80211/ieee80211_i.h b/net/mac80211/ieee80211_i.h
index b222a9afd4e9..99ff7c5e9204 100644
--- a/net/mac80211/ieee80211_i.h
+++ b/net/mac80211/ieee80211_i.h
@@ -99,6 +99,12 @@ struct ieee80211_sta_bss {
int probe_resp;
unsigned long last_update;
+ /* during assocation, we save an ERP value from a probe response so
+ * that we can feed ERP info to the driver when handling the
+ * association completes. these fields probably won't be up-to-date
+ * otherwise, you probably don't want to use them. */
+ int has_erp_value;
+ u8 erp_value;
};
diff --git a/net/mac80211/ieee80211_sta.c b/net/mac80211/ieee80211_sta.c
index f3ca83743b48..df6c410de161 100644
--- a/net/mac80211/ieee80211_sta.c
+++ b/net/mac80211/ieee80211_sta.c
@@ -314,6 +314,27 @@ static void ieee80211_sta_wmm_params(struct net_device *dev,
}
+static void ieee80211_handle_erp_ie(struct net_device *dev, u8 erp_value)
+{
+ struct ieee80211_local *local = wdev_priv(dev->ieee80211_ptr);
+ struct ieee80211_sub_if_data *sdata = IEEE80211_DEV_TO_SUB_IF(dev);
+ struct ieee80211_if_sta *ifsta = &sdata->u.sta;
+ int use_protection = (erp_value & WLAN_ERP_USE_PROTECTION) != 0;
+
+ if (use_protection != !!ifsta->use_protection) {
+ if (net_ratelimit()) {
+ printk(KERN_DEBUG "%s: CTS protection %s (BSSID="
+ MAC_FMT ")\n",
+ dev->name,
+ use_protection ? "enabled" : "disabled",
+ MAC_ARG(ifsta->bssid));
+ }
+ ifsta->use_protection = use_protection ? 1 : 0;
+ local->cts_protect_erp_frames = use_protection;
+ }
+}
+
+
static void ieee80211_sta_send_associnfo(struct net_device *dev,
struct ieee80211_if_sta *ifsta)
{
@@ -377,9 +398,18 @@ static void ieee80211_set_associated(struct net_device *dev,
if (assoc) {
struct ieee80211_sub_if_data *sdata;
+ struct ieee80211_sta_bss *bss;
sdata = IEEE80211_DEV_TO_SUB_IF(dev);
if (sdata->type != IEEE80211_IF_TYPE_STA)
return;
+
+ bss = ieee80211_rx_bss_get(dev, ifsta->bssid);
+ if (bss) {
+ if (bss->has_erp_value)
+ ieee80211_handle_erp_ie(dev, bss->erp_value);
+ ieee80211_rx_bss_put(dev, bss);
+ }
+
netif_carrier_on(dev);
ifsta->prev_bssid_set = 1;
memcpy(ifsta->prev_bssid, sdata->u.sta.bssid, ETH_ALEN);
@@ -1177,6 +1207,18 @@ static void ieee80211_rx_mgmt_assoc_resp(struct net_device *dev,
return;
}
+ /* it probably doesn't, but if the frame includes an ERP value then
+ * update our stored copy */
+ if (elems.erp_info && elems.erp_info_len >= 1) {
+ struct ieee80211_sta_bss *bss
+ = ieee80211_rx_bss_get(dev, ifsta->bssid);
+ if (bss) {
+ bss->erp_value = elems.erp_info[0];
+ bss->has_erp_value = 1;
+ ieee80211_rx_bss_put(dev, bss);
+ }
+ }
+
printk(KERN_DEBUG "%s: associated\n", dev->name);
ifsta->aid = aid;
ifsta->ap_capab = capab_info;
@@ -1499,6 +1541,12 @@ static void ieee80211_rx_bss_info(struct net_device *dev,
return;
}
+ /* save the ERP value so that it is available at association time */
+ if (elems.erp_info && elems.erp_info_len >= 1) {
+ bss->erp_value = elems.erp_info[0];
+ bss->has_erp_value = 1;
+ }
+
bss->beacon_int = le16_to_cpu(mgmt->u.beacon.beacon_int);
bss->capability = le16_to_cpu(mgmt->u.beacon.capab_info);
if (elems.ssid && elems.ssid_len <= IEEE80211_MAX_SSID_LEN) {
@@ -1614,10 +1662,8 @@ static void ieee80211_rx_mgmt_beacon(struct net_device *dev,
size_t len,
struct ieee80211_rx_status *rx_status)
{
- struct ieee80211_local *local = wdev_priv(dev->ieee80211_ptr);
struct ieee80211_sub_if_data *sdata;
struct ieee80211_if_sta *ifsta;
- int use_protection;
size_t baselen;
struct ieee802_11_elems elems;
@@ -1641,23 +1687,8 @@ static void ieee80211_rx_mgmt_beacon(struct net_device *dev,
&elems) == ParseFailed)
return;
- use_protection = 0;
- if (elems.erp_info && elems.erp_info_len >= 1) {
- use_protection =
- (elems.erp_info[0] & ERP_INFO_USE_PROTECTION) != 0;
- }
-
- if (use_protection != !!ifsta->use_protection) {
- if (net_ratelimit()) {
- printk(KERN_DEBUG "%s: CTS protection %s (BSSID="
- MAC_FMT ")\n",
- dev->name,
- use_protection ? "enabled" : "disabled",
- MAC_ARG(ifsta->bssid));
- }
- ifsta->use_protection = use_protection ? 1 : 0;
- local->cts_protect_erp_frames = use_protection;
- }
+ if (elems.erp_info && elems.erp_info_len >= 1)
+ ieee80211_handle_erp_ie(dev, elems.erp_info[0]);
if (elems.wmm_param && ifsta->wmm_enabled) {
ieee80211_sta_wmm_params(dev, ifsta, elems.wmm_param,
OpenPOWER on IntegriCloud