summaryrefslogtreecommitdiffstats
path: root/net/mac80211
diff options
context:
space:
mode:
authorDaniel Drake <dsd@gentoo.org>2007-07-10 19:32:10 +0200
committerJohn W. Linville <linville@tuxdriver.com>2007-07-12 16:07:26 -0400
commit5628221caf88e2a052782b042e12da7cd34111b0 (patch)
treeb4dbee3be1aa2b39e3d4c6f384b28d07740465fd /net/mac80211
parent1fd5e589d8c7d3cd42ddd39358338766cfcedec8 (diff)
downloadblackbird-op-linux-5628221caf88e2a052782b042e12da7cd34111b0.tar.gz
blackbird-op-linux-5628221caf88e2a052782b042e12da7cd34111b0.zip
[PATCH] mac80211: ERP IE handling improvements
The "protection needed" flag is currently parsed out of the ERP IE in beacons. This patch allows the ERP IE to be available at assocation time and causes the appropriate actions to be performed earlier. It is slightly complicated by the fact that most APs don't include the ERP IE in association responses. To work around this, we store ERP values in the ieee80211_sta_bss structure. Also added some WLAN_ERP defines for use by upcoming patches. Signed-off-by: Jiri Benc <jbenc@suse.cz> Signed-off-by: John W. Linville <linville@tuxdriver.com>
Diffstat (limited to 'net/mac80211')
-rw-r--r--net/mac80211/ieee80211_i.h6
-rw-r--r--net/mac80211/ieee80211_sta.c69
2 files changed, 56 insertions, 19 deletions
diff --git a/net/mac80211/ieee80211_i.h b/net/mac80211/ieee80211_i.h
index b222a9afd4e9..99ff7c5e9204 100644
--- a/net/mac80211/ieee80211_i.h
+++ b/net/mac80211/ieee80211_i.h
@@ -99,6 +99,12 @@ struct ieee80211_sta_bss {
int probe_resp;
unsigned long last_update;
+ /* during assocation, we save an ERP value from a probe response so
+ * that we can feed ERP info to the driver when handling the
+ * association completes. these fields probably won't be up-to-date
+ * otherwise, you probably don't want to use them. */
+ int has_erp_value;
+ u8 erp_value;
};
diff --git a/net/mac80211/ieee80211_sta.c b/net/mac80211/ieee80211_sta.c
index f3ca83743b48..df6c410de161 100644
--- a/net/mac80211/ieee80211_sta.c
+++ b/net/mac80211/ieee80211_sta.c
@@ -314,6 +314,27 @@ static void ieee80211_sta_wmm_params(struct net_device *dev,
}
+static void ieee80211_handle_erp_ie(struct net_device *dev, u8 erp_value)
+{
+ struct ieee80211_local *local = wdev_priv(dev->ieee80211_ptr);
+ struct ieee80211_sub_if_data *sdata = IEEE80211_DEV_TO_SUB_IF(dev);
+ struct ieee80211_if_sta *ifsta = &sdata->u.sta;
+ int use_protection = (erp_value & WLAN_ERP_USE_PROTECTION) != 0;
+
+ if (use_protection != !!ifsta->use_protection) {
+ if (net_ratelimit()) {
+ printk(KERN_DEBUG "%s: CTS protection %s (BSSID="
+ MAC_FMT ")\n",
+ dev->name,
+ use_protection ? "enabled" : "disabled",
+ MAC_ARG(ifsta->bssid));
+ }
+ ifsta->use_protection = use_protection ? 1 : 0;
+ local->cts_protect_erp_frames = use_protection;
+ }
+}
+
+
static void ieee80211_sta_send_associnfo(struct net_device *dev,
struct ieee80211_if_sta *ifsta)
{
@@ -377,9 +398,18 @@ static void ieee80211_set_associated(struct net_device *dev,
if (assoc) {
struct ieee80211_sub_if_data *sdata;
+ struct ieee80211_sta_bss *bss;
sdata = IEEE80211_DEV_TO_SUB_IF(dev);
if (sdata->type != IEEE80211_IF_TYPE_STA)
return;
+
+ bss = ieee80211_rx_bss_get(dev, ifsta->bssid);
+ if (bss) {
+ if (bss->has_erp_value)
+ ieee80211_handle_erp_ie(dev, bss->erp_value);
+ ieee80211_rx_bss_put(dev, bss);
+ }
+
netif_carrier_on(dev);
ifsta->prev_bssid_set = 1;
memcpy(ifsta->prev_bssid, sdata->u.sta.bssid, ETH_ALEN);
@@ -1177,6 +1207,18 @@ static void ieee80211_rx_mgmt_assoc_resp(struct net_device *dev,
return;
}
+ /* it probably doesn't, but if the frame includes an ERP value then
+ * update our stored copy */
+ if (elems.erp_info && elems.erp_info_len >= 1) {
+ struct ieee80211_sta_bss *bss
+ = ieee80211_rx_bss_get(dev, ifsta->bssid);
+ if (bss) {
+ bss->erp_value = elems.erp_info[0];
+ bss->has_erp_value = 1;
+ ieee80211_rx_bss_put(dev, bss);
+ }
+ }
+
printk(KERN_DEBUG "%s: associated\n", dev->name);
ifsta->aid = aid;
ifsta->ap_capab = capab_info;
@@ -1499,6 +1541,12 @@ static void ieee80211_rx_bss_info(struct net_device *dev,
return;
}
+ /* save the ERP value so that it is available at association time */
+ if (elems.erp_info && elems.erp_info_len >= 1) {
+ bss->erp_value = elems.erp_info[0];
+ bss->has_erp_value = 1;
+ }
+
bss->beacon_int = le16_to_cpu(mgmt->u.beacon.beacon_int);
bss->capability = le16_to_cpu(mgmt->u.beacon.capab_info);
if (elems.ssid && elems.ssid_len <= IEEE80211_MAX_SSID_LEN) {
@@ -1614,10 +1662,8 @@ static void ieee80211_rx_mgmt_beacon(struct net_device *dev,
size_t len,
struct ieee80211_rx_status *rx_status)
{
- struct ieee80211_local *local = wdev_priv(dev->ieee80211_ptr);
struct ieee80211_sub_if_data *sdata;
struct ieee80211_if_sta *ifsta;
- int use_protection;
size_t baselen;
struct ieee802_11_elems elems;
@@ -1641,23 +1687,8 @@ static void ieee80211_rx_mgmt_beacon(struct net_device *dev,
&elems) == ParseFailed)
return;
- use_protection = 0;
- if (elems.erp_info && elems.erp_info_len >= 1) {
- use_protection =
- (elems.erp_info[0] & ERP_INFO_USE_PROTECTION) != 0;
- }
-
- if (use_protection != !!ifsta->use_protection) {
- if (net_ratelimit()) {
- printk(KERN_DEBUG "%s: CTS protection %s (BSSID="
- MAC_FMT ")\n",
- dev->name,
- use_protection ? "enabled" : "disabled",
- MAC_ARG(ifsta->bssid));
- }
- ifsta->use_protection = use_protection ? 1 : 0;
- local->cts_protect_erp_frames = use_protection;
- }
+ if (elems.erp_info && elems.erp_info_len >= 1)
+ ieee80211_handle_erp_ie(dev, elems.erp_info[0]);
if (elems.wmm_param && ifsta->wmm_enabled) {
ieee80211_sta_wmm_params(dev, ifsta, elems.wmm_param,
OpenPOWER on IntegriCloud